Abstract
This paper discusses the improvement of high speed flat lapping machine with grating measuring length system and an MCS-51 single chip computer, which makes the machine possesses the ability of measuring and controlling for lapping quantity and improves the machine property and machining accuracy. The original size and need size of workpiece are known. The difference between of them is lapping quantity (before lapping) is input into the computer. In lapping the grating measuring length system on- line measures the lapping quantity, the computer compares the measured lapping quantity with l, makes a decision according to the comparing result and decides whether to stop the machine. When the measured lapping quantity equals l, it is expressed that the workpiece is lapped to required size, the computer makes the machine stop, which assures the workpiece size accuracy automatically, improves machine automaticity and makes up the disadvantages that an ordinary flat lapping machine can not control the lapping size effectively. Through experiments it is found that measuring and controlling accuracy of improved lapping machine is +/- 2 micrometers .
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jiandong Yang, Jiawu Song, Xueqian Li, and Lijiang Wang "Improving high-speed flat lapping machine with NC", Proc. SPIE 3557, Current Developments in Optical Elements and Manufacturing, (5 August 1998); https://doi.org/10.1117/12.318308
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Head

Abrasives

Computing systems

Distance measurement

Solids

Sensors

Signal processing

RELATED CONTENT


Back to Top