Paper
4 November 1981 Comparison Of Digital Subtraction Video Densitometry And Area Length Method In The Determination Of Left Ventricular Ejection Fraction
O. Nalcioglu, J. A. Seibert, W. W. Roeck, W. L. Henry, J. M. Tobis, W. D. Johnston
Author Affiliations +
Abstract
Digital subtraction video densitometry is utilized in the determination of left ventricular ejection fraction. The mask mode subtracted video images obtained after a peripheral intravenous injection of a bolus of Renografin 76 are used in the derivation of a density time curve. The left ventricular ejection fraction (LVEF) is computed by an algorithm described in this paper. Results for 15 patients are compared to the LVEF's obtained by applying the area-length method to the same patient data. The left ventricular ejection fractions computed by both methods had a good correlation (r=0.96) in fifteen patients.*
© (1981) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
O. Nalcioglu, J. A. Seibert, W. W. Roeck, W. L. Henry, J. M. Tobis, and W. D. Johnston "Comparison Of Digital Subtraction Video Densitometry And Area Length Method In The Determination Of Left Ventricular Ejection Fraction", Proc. SPIE 0314, Digital Radiography, (4 November 1981); https://doi.org/10.1117/12.933061