Paper
3 March 2017 Evaluation of blood glucose concentration measurement using photoacoustic spectroscopy in near-infrared region
Takeshi Namita, Mitsuki Sato, Kengo Kondo, Makoto Yamakawa, Tsuyoshi Shiina
Author Affiliations +
Abstract
Diabetes, a typical lifestyle-related disease, is an important disease presenting risks of various complications such as retinopathy, kidney failure, and nervous neuropathy. To treat diabetes, regular and continual self-measurement of blood glucose concentrations is necessary to maintain blood glucose levels and to prevent complications. Usually, daily measurements are taken using invasive methods such as finger-prick blood sampling. Some non-invasive optical techniques have been proposed to reduce pain and infection risk, however, few practical techniques exist today. To realize highly accurate and practical measurement of blood glucose concentrations, the feasibility of a photoacoustic method using near-infrared light was evaluated. A photoacoustic signal from a solution of glucose in water (+0–5 g/dl) or equine blood (+0–400 mg/dl) was measured using a hydrophone (9 mm diameter) at 800–1800 nm wavelengths. We investigated the relation between the glucose solution concentration and the photoacoustic signal intensity or peak position of the received photoacoustic signal (i.e. speed of sound in solutions). Results show that the signal intensity and sound speed of the glucose solution increase with increased glucose concentration for wavelengths at which light absorbance of glucose is high. For quantitative estimation of the glucose solution concentration, the photoacoustic signal intensity ratio between two wavelengths, at which dependence of the signal intensity on glucose concentration is high and low, was calculated. Results confirmed that the signal intensity ratios increase linearly with the glucose concentration. These analyses verified the feasibility of glucose level estimation using photoacoustic measurement in the near-infrared region.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Takeshi Namita, Mitsuki Sato, Kengo Kondo, Makoto Yamakawa, and Tsuyoshi Shiina "Evaluation of blood glucose concentration measurement using photoacoustic spectroscopy in near-infrared region", Proc. SPIE 10064, Photons Plus Ultrasound: Imaging and Sensing 2017, 100645A (3 March 2017); https://doi.org/10.1117/12.2252532
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glucose

Photoacoustic spectroscopy

Blood

Absorbance

Absorption

Kidney

Near infrared spectroscopy

Back to Top