Paper
7 June 1989 Fundamental Studies For The Triple-Flash X-Ray Generator For Biomedical Radiography
Eiichi Sato, Satoshi Kawasaki, Hiroshi Isobe, Yoshiharu Tamakawa, Toru Yanagisawa
Author Affiliations +
Proceedings Volume 1032, 18th Intl Congress on High Speed Photography and Photonics; (1989) https://doi.org/10.1117/12.969103
Event: 18th International Congress on High Speed Photography and Photonics, 1988, Xi'an, Shaanxi, China
Abstract
The fundamental studies for the triple-flash x-ray generator having variable spectra for biomedical radiography are described. Two types of triple-flash x-ray generators consisted of the following components: a high-voltage generating unit, a voltage divider unit, three high-voltage pulsers, a triple-parallel impulse switching system utilizing air gap pulsers for the main gas gaps, a high-power gas diode having three terminals, a turbo molecular pump, and three x-ray tubes having cold cathodes. For the single-tube generator, the pulse condensers of the pulsers were charged to the same or different energies by using a voltage divider unit and were connected to the x-ray tube through a high-power gas diode. In contrast, the pulsers were connected directly to three tubes without a diode. The duration of each x-ray pulse was a few ps, and the minimum time interval between two pulses was about 100ps (single-tube type), the x-ray intensity was less than lx10-5C/kg at lm per pulse, and the effective focal spot size was determined by the diameter of the anode rod. The triple exposure of pulsed x-rays having variable spectra and time intervals was obtained.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Satoshi Kawasaki, Hiroshi Isobe, Yoshiharu Tamakawa, and Toru Yanagisawa "Fundamental Studies For The Triple-Flash X-Ray Generator For Biomedical Radiography", Proc. SPIE 1032, 18th Intl Congress on High Speed Photography and Photonics, (7 June 1989); https://doi.org/10.1117/12.969103
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Radiography

Diodes

Photonics

Aluminum

Biomedical optics

Switching

RELATED CONTENT

Biomedical Flash Radiography
Proceedings of SPIE (February 04 1988)
A Serial Exposure Type of High Intensity Flash X ray...
Proceedings of SPIE (December 08 1986)
High Intensity Soft Flash X Ray Generator with Two Types...
Proceedings of SPIE (December 08 1986)
A Flash Radiographic System For Biomedical Use
Proceedings of SPIE (June 07 1989)

Back to Top