31 January 1994 Fourier transform infrared spectroscopy in environmental research: mobile remote sensing of air pollution
Rainer Haus, Klaus Schaefer, Herbert W. Mosebach, Joerg Heland
Author Affiliations +
Proceedings Volume 2089, 9th International Conference on Fourier Transform Spectroscopy; (1994) https://doi.org/10.1117/12.166588
Event: Fourier Transform Spectroscopy: Ninth International Conference, 1993, Calgary, Canada
Abstract
Measurements with a mobile laboratory for FTIS remote sensing of pollution in ambient air and directed effluent streams (smokestacks and aircraft engines) are reported. The Double Pendulum Interferometer K300 and a multi-component radiative transfer analysis software were used to quantify the molecules CO, CO2, NO, NO2, N2O, SO2, HCl, H2O, CH4, NH3, HCHO and HC every 5 - 10 minutes in good agreement with in-situ sensors.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Rainer Haus, Klaus Schaefer, Herbert W. Mosebach, and Joerg Heland "Fourier transform infrared spectroscopy in environmental research: mobile remote sensing of air pollution", Proc. SPIE 2089, 9th International Conference on Fourier Transform Spectroscopy, (31 January 1994); https://doi.org/10.1117/12.166588