30 May 1995 High-speed soft x-ray generators in biomedicine
Eiichi Sato, Michiaki Sagae, Kei Takahashi, Teiji Oizumi, Hidenori Ojima, Kazuyoshi Takayama, Yoshiharu Takayama, Toru Yanagisawa, Akihiro Fujiwara, Kanji Mitoya
Author Affiliations +
Proceedings Volume 2513, 21st International Congress on: High-Speed Photography and Photonics; (1995) https://doi.org/10.1117/12.209662
Event: High-Speed Photography and Photonics: 21st International Congress, 1994, Taejon, Korea, Republic of
Abstract
The constructions and the fundamental studies of high-speed soft x-ray generators which can be used for performing biomedical radiography with maximum photon energies of less than 150 keV are described. The flash x- ray generators having cold-cathode radiation tubes are classified to four types: (1) high-intensity single flash x-ray generators, (2) dual- energy flash x-ray generators, (3) single plasma flash x-ray generators, and (4) repetitive compact flash x-ray generators. In general, when we employed flash x-ray generators with diodes, the pulse widths had values of less than 200 ns. In the case where we employed a long-duration flash x-ray generator having a triode, the width could be increased up to about 40 microsecond(s) . The maximum tube currents achieved with high-intensity generators were more than 10 kA, and the maximum repetition rate of a compact generator has a value of about 0.4 kHz. In order to obtain higher repetition rates of more than 1 kHz, we developed three types of pulsed x-ray generators having hot-cathode tubes as follows: (5) a 30 kHz high-dose-rate generator, (6) a 30 kHz variable-duration microsecond generator, and (7) two 10 kHz high-photon-energy generators. When a high-dose-rate generator was employed, the maximum tube current can be increased up to about 2 A by applying the positive grid voltage. In contrast, as the duration was controlled in a microsecond range by using a microsecond generator, the sufficient x-ray intensities for the normal radiography were obtained. The maximum photon energy could be increased more than 100 keV using a high-voltage transformer in conjunction with a diode. Using these generators, we performed various kinds of high- speed soft radiographies.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Michiaki Sagae, Kei Takahashi, Teiji Oizumi, Hidenori Ojima, Kazuyoshi Takayama, Yoshiharu Takayama, Toru Yanagisawa, Akihiro Fujiwara, and Kanji Mitoya "High-speed soft x-ray generators in biomedicine", Proc. SPIE 2513, 21st International Congress on: High-Speed Photography and Photonics, (30 May 1995); https://doi.org/10.1117/12.209662
Lens.org Logo
CITATIONS
Cited by 16 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Radiography

Diodes

Virtual colonoscopy

Plasma

Plasma generation

Electrodes

RELATED CONTENT


Back to Top