Paper
11 July 1997 Performance expectation versus reality
Leon P. Van Speybroeck, Diab Jerius, Richard J. Edgar, Terrance J. Gaetz, Ping Zhao, Paul B. Reid
Author Affiliations +
Abstract
The AXAF (Advanced X-ray Astrophysics Facility) high resolution mirror assembly (HRMA) now is complete and has been tested at the NASA Marshall Space Flight Center (MSFC) X-ray Calibration Facility (XRCF). The surface and alignment properties of the mirror were thoroughly measured before the x-ray test, which allowed accurate performance predictions to be performed. The preliminary analysis of the measured x-ray image distributions for all energies tested show excellent agreement with predictions made before the beginning of the test. There is a discrepancy between the measured and predicted effective areas; this typically is less than 5%, and is less than 13% for all energies measured. We present evidence that this discrepancy is due to uncertainties in the calibration of the test instrumentation, and therefore can be expected to be reduced when results from further instrument calibration tests now in progress are incorporated into the analysis. We predict that 65 - 80% (depending upon energy) of the flux from an imaged point source will be contained on a one arc second diameter aperture in flight. We expect the HRMA to more than fulfill the requirements necessary to achieve the AXAF scientific objectives.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Leon P. Van Speybroeck, Diab Jerius, Richard J. Edgar, Terrance J. Gaetz, Ping Zhao, and Paul B. Reid "Performance expectation versus reality", Proc. SPIE 3113, Grazing Incidence and Multilayer X-Ray Optical Systems, (11 July 1997); https://doi.org/10.1117/12.278890
Lens.org Logo
CITATIONS
Cited by 65 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

X-rays

Scattering

Monochromatic aberrations

Optical components

Calibration

Coating

RELATED CONTENT

X ray study of W Si multilayers for the HEFT...
Proceedings of SPIE (January 29 2004)
Calibrating the wings of the Chandra PSF
Proceedings of SPIE (February 03 2004)
Optical Surface Evaluation By Soft X-Ray Scattering
Proceedings of SPIE (August 12 1986)
Verifying the HETG spectrometer Rowland design
Proceedings of SPIE (November 19 1998)

Back to Top