28 August 2003 New repair of clear defects on half-tone PSM using Ga implantation
Yoshikazu Nagamura, Itaru Kanai, Koji Tange, Kunihiro Hosono, Koki Hayashi, Hidehiro Ikeda, Susumu Nagashige, Mikio Ishijima, Hironobu Iwasaki, Yasutaka Kikuchi
Author Affiliations +
Abstract
The new repair of the clear defects on the half-tone PSM (EAPSM) was proposed. The Ga (gallium) ions were implanted by the FIB on the area adjacent to the carbon films formed on the clear defects. The Ga ion implanted area on the SiO2 substrate showed the semi-transparency at the KrF and ArF wavelengths. The lithography simulations of the layouts designed for the defect-repaired area endorsed the concept of the new repair. The Ga ion implantation was optimized to the new repair by using the AIMS and AFM measurements for the transmittance and etched depth of the SiO2 surface. The authors applied this method to the clear defects programmed on the KrF and ArF EAPSMs. The AIMS analysis showed that the deviation of the CD (critical dimension) of the defect-repaired regions on the wafer was within +/-5% to the non-defective reference at every defocused point. The new repair moderated the specification of the edge placement accuracy of the FIB processing compared to the conventional carbon film deposition.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yoshikazu Nagamura, Itaru Kanai, Koji Tange, Kunihiro Hosono, Koki Hayashi, Hidehiro Ikeda, Susumu Nagashige, Mikio Ishijima, Hironobu Iwasaki, and Yasutaka Kikuchi "New repair of clear defects on half-tone PSM using Ga implantation", Proc. SPIE 5130, Photomask and Next-Generation Lithography Mask Technology X, (28 August 2003); https://doi.org/10.1117/12.504208
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Carbon

Gallium

Critical dimension metrology

Semiconducting wafers

Ions

Transmittance

Image processing

RELATED CONTENT

Mask critical dimension error on optical lithography
Proceedings of SPIE (July 19 2000)
Advanced FIB mask repair technology in ArF lithography
Proceedings of SPIE (July 19 2000)
Focused ion beam repair of 193 nm reticle at 0.18...
Proceedings of SPIE (February 12 1997)
Advanced FIB mask repair technology for ArF lithography: II
Proceedings of SPIE (January 22 2001)
FIB repair of 5x reticles and effects on IC quality
Proceedings of SPIE (August 04 1993)

Back to Top