Paper
2 September 2008 Probabilistic method for multiparameter tolerancing in illuminator design
Stan Smirnov, Eric Catey
Author Affiliations +
Abstract
In precision optical instruments, it is often the case that aspects of the illumination system pupil--such as ellipticity, telecentricity, and partial coherence--relate directly to image resolution and placement accuracy. Standard design and analysis tools are often ill-suited to performing tolerance analyses on illuminators, since the figures-of-merit in terms of system performance do not reduce neatly to wavefront and distortion, as they often do for imaging optics. In order to address these deficiencies, we developed a multiparameter tolerancing method based on a probabilistic treatment of errors in an illumination system, and we will describe the work we have done in this paper.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Stan Smirnov and Eric Catey "Probabilistic method for multiparameter tolerancing in illuminator design", Proc. SPIE 7068, Optical System Alignment and Tolerancing II, 706802 (2 September 2008); https://doi.org/10.1117/12.795187
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tolerancing

Fiber optic illuminators

Error analysis

Imaging systems

Ray tracing

Computing systems

Optical design

RELATED CONTENT

Tolerancing panoramic lenses
Proceedings of SPIE (August 21 2009)
Critical view of three lens design methods damped least...
Proceedings of SPIE (September 20 2002)
Imaging limitations related to the skew invariant
Proceedings of SPIE (December 10 2001)
Illumination system tolerancing
Proceedings of SPIE (September 21 2007)

Back to Top