Paper
10 February 2009 Small-size meshless 50 ps streak tube
N. V. Ageeva, S. V. Andreev, V. S. Belolipetski, G. I. Bryukhnevich, D. E. Greenfield, S. R. Ivanova, A. M. Kaverin, A. N. Khohlova, E. A. Kuz’menko, G. P. Levina, V. A. Makushina, M. A. Monastyrskiy, M. Ya. Schelev, Z. M. Semichastnova, Yu. N. Serdyuchenko, T. A. Skaballanovich, V. E. Sokolov
Author Affiliations +
Proceedings Volume 7126, 28th International Congress on High-Speed Imaging and Photonics; 71260A (2009) https://doi.org/10.1117/12.821670
Event: 28th International Congress on High-Speed Imaging and Photonics, 2008, Canberra, Australia
Abstract
In contrast to the conventional image intensifier with large work area, a streak image tube should possess additional important feature - the comparatively small temporal distortion at the entire work area of the photocathode. With this additional engineering restriction taken into account, a novel small-size meshless streak image tube has been developed by means of numerical optimization. The tube with 25-mm wide work area contains a pair of deflection plates to sweep the electron image along the 25 mm output phosphor screen that is separated by 100 mm from the photocathode. The electron image can be shuttered with a 300 V blanking electric pulse. Electron-optical magnification of the tube is unit; spatial resolution reaches 30 lp/mm over the entire photocathode work area; temporal resolution lies in the 20 - 50 ps range, depending on the accelerating voltage (6 - 15 kV).
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
N. V. Ageeva, S. V. Andreev, V. S. Belolipetski, G. I. Bryukhnevich, D. E. Greenfield, S. R. Ivanova, A. M. Kaverin, A. N. Khohlova, E. A. Kuz’menko, G. P. Levina, V. A. Makushina, M. A. Monastyrskiy, M. Ya. Schelev, Z. M. Semichastnova, Yu. N. Serdyuchenko, T. A. Skaballanovich, and V. E. Sokolov "Small-size meshless 50 ps streak tube", Proc. SPIE 7126, 28th International Congress on High-Speed Imaging and Photonics, 71260A (10 February 2009); https://doi.org/10.1117/12.821670
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Picosecond phenomena

Spatial resolution

Electrodes

Manufacturing

Temporal resolution

Design for manufacturability

Computer simulations

RELATED CONTENT

Large photocathode area picosecond streak tube
Proceedings of SPIE (February 10 2009)
Demountable Photocathode X-Ray Streak Camera
Proceedings of SPIE (January 09 1984)
P 700 A New High Speed Streak Tube...
Proceedings of SPIE (February 01 1985)
A Picosecond Streak Image Tube
Proceedings of SPIE (February 01 1985)

Back to Top