Paper
21 July 2010 First results using PRIMA FSU as a fringe tracker for MIDI
A. Müller, J.-U. Pott, S. Morel, R. Abuter, G. van Belle, R. van Boekel, L. Burtscher, F. Delplancke, Th. Henning, W. Jaffe, Ch. Leinert, B. Lopez, A. Matter, K. Meisenheimer, C. Schmid, K. Tristram, A. P. Verhoeff
Author Affiliations +
Abstract
We report first results obtained from observations using a PRIMA FSU (Fringe Sensor Unit) as a fringe tracker for MIDI on the VLTI when operating with the 1.8-m ATs. Interferometric observations require the correction of the disturbance in the optical path induced by atmospheric turbulence ("piston"). The PRIMA FSU is able to compensate for such disturbances in real-time which makes it a suitable facility to stabilize the fringe signal for other VLTI instruments, like AMBER, MIDI or later MATISSE. Currently, the atmospheric coherence time in the N band (8 to 13 μm) observed by MIDI, as well as the thermal background in this band, require a minimum target flux of 20 Jy and a correlated flux of 10 Jy (in PRISM/HIGH SENSE mode and using the ATs under standard conditions) to allow self-fringe-tracking and data reduction. However, we show that if the fringes are stabilized by the FSU, coherent integration allows a reliable data reduction even for the observation of faint targets (Fcorr <10 Jy) with MIDI at standard detector exposure times. We were able to measure the correlated flux of a 0.5 Jy source, which pushes the current limits of MIDI down to regions where numerous new targets become accessible on ATs. For faint object observations we will discuss the usage of VISIR photometry for calibration purposes. The observational tests done so far and the obtained results represent a first step towards Phase Referenced Imaging with the VLTI in the mid-infrared.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. Müller, J.-U. Pott, S. Morel, R. Abuter, G. van Belle, R. van Boekel, L. Burtscher, F. Delplancke, Th. Henning, W. Jaffe, Ch. Leinert, B. Lopez, A. Matter, K. Meisenheimer, C. Schmid, K. Tristram, and A. P. Verhoeff "First results using PRIMA FSU as a fringe tracker for MIDI", Proc. SPIE 7734, Optical and Infrared Interferometry II, 773420 (21 July 2010); https://doi.org/10.1117/12.857754
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Stars

Astatine

Calibration

Interferometry

K band

Photometry

Visibility

RELATED CONTENT


Back to Top