Paper
22 September 2011 Preliminary investigation of lanthanum-cerium bromide self-activity removal
Author Affiliations +
Abstract
It has been reported that detectors made of lanthanum-cerium halides (LaBr3:Ce and CeBr3) have superior energy resolution for gamma-radiation detection compared to what is offered by conventional sodium iodide (NaI:T1) detectors. Although superior energy resolution may be observed, one major barrier that has hindered the rapid adaptation of lanthanum halides is their self-activity, due primarily to the presence of isotope 138La, and the α contamination, due to the trace amount of actinides. It has also been observed that the lanthanum-cerium halides contain a substantial amount of self-activity caused by the radioactive isotope 138La. Additionally, LaBr3:Ce spectra are also affected by β contaminations in the low-energy region. To use either LaBr3:Ce or CeBr3 for high-sensitivity gamma detection, it may be necessary to have the self-activity as well as α and β contaminations removed or reduced. This paper describes a novel algorithmic approach for self-activity and contamination reduction for LaBr3:Ce and CeBr3 detectors using a third reference NaI:T1 detector. We present a computational procedure for separating self-activity from the gamma spectra obtained by LaBr3:Ce detectors. With the self-activity spectra precalculated, it is possible to perform real-time self-activity removal. This procedure can be implemented as an automatic self-activity subtraction module for gamma-radiation detectors made of LaBr3:Ce and/or CeBr3 crystals. With this approach, it is possible to develop a new generation of LaBr3:Ce detectors capable of producing spectra as clean as those obtained by conventional NaI:T1 detectors, but with much improved energy resolutions.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ding Yuan and Paul Guss "Preliminary investigation of lanthanum-cerium bromide self-activity removal", Proc. SPIE 8144, Penetrating Radiation Systems and Applications XII, 814402 (22 September 2011); https://doi.org/10.1117/12.890903
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Crystals

Contamination

Lanthanum

Cerium

Manufacturing

Data processing

RELATED CONTENT

Laser sensor for monitoring radioactive contamination
Proceedings of SPIE (November 17 2014)
Structure and properties of lanthanide halides
Proceedings of SPIE (October 02 2007)
InI photodetectors for scintillation spectroscopy
Proceedings of SPIE (December 22 1992)
Assessment of molecular contamination in mask pod
Proceedings of SPIE (May 02 2008)

Back to Top