23 February 2012 Investigation of ultra low-dose scans in the context of quantum-counting clinical CT
T. Weidinger, T. M. Buzug, T. Flohr, G. S. K. Fung, S. Kappler, K. Stierstorfer, B. M. W. Tsui
Author Affiliations +
Abstract
In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
T. Weidinger, T. M. Buzug, T. Flohr, G. S. K. Fung, S. Kappler, K. Stierstorfer, and B. M. W. Tsui "Investigation of ultra low-dose scans in the context of quantum-counting clinical CT", Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83134B (23 February 2012); https://doi.org/10.1117/12.911331
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Electroluminescence

X-ray computed tomography

Electronics

X-rays

Abdomen

Scanners

Back to Top