24 July 2014 Ground-based x-ray calibration of the Astro-H soft x-ray telescopes
Author Affiliations +
Abstract
The X-ray astronomy satellite Astro-H, planned to be launched in 2015, will have several instruments for covering a wide energy band from a few hundreds eV to 600 keV. There are four X-ray telescopes, and two of them are soft X-ray telescopes (SXTs) covering up to about 15 keV. One is for an X-ray micro-calorimeter detector (SXS) and the other is for an X-ray CCD detector (SXI). The design of the SXTs is a conical approximation of the Wolter Type-I optics, which is also adopted for the telescopes on the previous mission Suzaku launched in 2005. It consists 203 thin-foil reflectors coated with gold monolayer (2000 Å) on the aluminum substrate (101.6 mm length) with the thickness of 0.15, 0.23 and 0.31 mm. These are nested confocally within the radius of 58 to 225 mm. The focal length of SXTs is 5.6 m. The weight is as light as ~ 43 kg per telescope.

We present the current status of the calibration activity of two SXTs (SXT-1 and SXT-2). The developments of two SXTs were completed by NASA's Goddard Space Flight Center (GSFC). First X-ray measurements with a diverging beam at the GSFC 100m beamline found an angular resolution at 8.0 keV to be 1.1 and 1.0 arcmin (HPD) for SXT-1 and SXT-2, respectively. The full characterization of the X-ray performance has been now continuously calibrated with the 30m X-ray beamline facility at the Institute of Space and Astronautical Science (ISAS) of Japan Aerospace eXploration Agency (JAXA) in Japan. We adopted a raster scan method with a narrow X-ray pencil beam with the divergence of ~ 15". X-ray characterization of the two SXTs has been measured from May and December 2013, respectively.

In the case of SXT-1, the on-axis effective area was approximately 580, 445, 370, 270, 185 and 90 cm2 at energies of 1.5, 4.5, 8.0, 9.4, 11.1 and 12.9 keV respectively. The effective area of SXT-2 is 2% larger than that of SXT-1 irrespective to X-ray energy. The on-axis angular resolution of SXT-1 was evaluated as 1.3 - 1.5 arcmin (HPD) in the 1.5 - 13 keV band. The resolution was slightly got worse at higher energies by ~ 0:3 arcmin. Otherwise, the resolution of SXT-2 is 1.2 arcmin, almost irrespective to X-ray energy. The field of view (FOV) was ~ 16 arcmin at 1.5 keV, decreasing with increasing X-ray energy, and became ~ 8 arcmin at 13 keV. The FOV is defined here as the full-width at half-maximum (FWHM) of the vignetting curve.

The X-ray performance of SXT-1 and SXT-2 meets the system requirements. Because all the parameters of the SXT-2 is slightly better that of SXT-1, we adopted the SXT-2 telescope for the SXS detector of the Astro-H primary instrument with the narrow FOV.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ryo Iizuka, Takayuki Hayashi, Yoshitomo Maeda, Manabu Ishida, Kazuki Tomikawa, Toshiki Sato, Naomichi Kikuchi, Takashi Okajima, Yang Soong, Peter J. Serlemitsos, Hideyuki Mori, Takanori Izumiya, and Sari Minami "Ground-based x-ray calibration of the Astro-H soft x-ray telescopes", Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 914458 (24 July 2014); https://doi.org/10.1117/12.2054626
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

X-ray telescopes

Sensors

Calibration

Telescopes

Vignetting

Data modeling

RELATED CONTENT

Status of ART-XC/SRG instrument
Proceedings of SPIE (July 24 2014)
ART XC SRG status of the x ray focal...
Proceedings of SPIE (July 25 2014)
ART XC SRG joint calibration of mirror modules and...
Proceedings of SPIE (August 29 2017)
ART-XC / SRG overview
Proceedings of SPIE (July 06 2018)
In orbit calibrations of XMM-Newton telescopes
Proceedings of SPIE (March 11 2003)

Back to Top