We present the current status of Hα high-contrast imaging observations with Subaru/Subaru Coronagraphic Extreme Adaptive Optics + VAMPIRES. Our adaptive optics correction at optical wavelengths in combination with (double) spectral differential imaging (SDI) and angular differential imaging (ADI) was capable of resolving a ring feature around omi Cet and detect the Hα counterpart of jet around RY Tau. We tested the post-processing by changing the order of ADI and SDI and both of the contrast limits achieved ∼10 − 3 to 5 × 10 − 4 at 0.3″, which is comparable to other Hα high-contrast imaging instruments in the Southern Hemisphere such as very large telescope (VLT)/spectro-polarimetric high-contrast exoplanet research, VLT/MUSE, and Magellan AO. Current wavefront sensing and adaptive optics correction at optical wavelengths empirically depend on airmass, and Subaru/VAMPIRES provide great opportunities for Hα high-contrast imaging for Northern Hemisphere targets. |
1.IntroductionObserving hydrogen lines provides fruitful opportunities to investigate mass accretion, shocks, jets, atmospheres, and other astrophysical phenomena. A variety of observations have been implemented, but previous observations basically targeted an isolated object or multi-objects that can be spatially resolved under seeing-limited conditions. An improvement in instrumentation has enabled better angular resolution than set by the seeing limit—adaptive optics (AO)1 systems can make real-time corrections to wavefront distortions by the Earth’s atmosphere using a guide star and delivers a point spread function (PSF) close to the diffraction-limited one. In particular, AO is very important for high-contrast imaging of exoplanets or protoplanetary disks by removing stellar halo and instrumental speckles that bury such faint signals in the stellar halo. However, the AO correction at optical wavelengths was difficult in the early years of the AO instruments because the Fried parameter ()2 is so small at optical wavelengths, and hence a large number of actuators are required across the telescope aperture and fast temporal operation for wavefront sensing. Therefore, classical AO instruments were mostly applied near-infrared (NIR) wavelengths (e.g., JHKLM band), which benefit exoplanetary science because low-mass objects have less contrast with respect to their host stars in the NIR and thus high-contrast imaging at these wavelengths provides the best sensitivity. Recently, further improvements in instrumentation have made it possible to operate AO correction at optical wavelengths [e.g., very large telescope (VLT)/multi unit spectroscopic explorer (MUSE),3 VLT/spectro-polarimetric high-contrast exoplanet research (SPHERE),4 Magellan AO (MagAO),5 and Subaru/Subaru Coronagraphic Extreme Adaptive Optics (SCExAO)6] and have kicked off a new era of high-contrast imaging at (). One of the most important subjects of observation with AO is active mass accretion onto protoplanets (e.g., PDS 70 bc7,8). Recent disk observations with ALMA or NIR polarimetric observations have shown a variety of asymmetric features within 1″ that may be related to planet formation (e.g., gap, ring, or spiral9,10), but the number of confirmed protoplanets is still smaller than the number of predictions of potential protoplanets. Therefore, the planet formation mechanism is still controversial, and exploring for planets at such inner regions while avoiding the stellar halo with high-performance AO correction is important. The performance at optical wavelengths with current instruments highly depends on airmass. For example, the performance of MUSE/narrow-field-mode empirically decreases with airmass (MUSE manual11). We also checked some archival MUSE data12 and compared airmass and full width at half maximum (FWHM) in the channel (see Table 1), which confirms the degradation of AO correction at high airmass. Poor AO correction leads to ineffective post-processing to remove the stellar halo and to achieve high contrast. As VLT and MagAO are located in the Southern Hemisphere, their observations of northern targets, e.g. the Taurus star-forming region, may not have sufficient sensitivity to detect in the vicinity of a star. Table 1VLT/MUSE archival data of YSOs.
Here, we have installed a new observing mode of The Visible Aperture Masking Polarimetric Imager for Resolved Exoplanetary Structures (VAMPIRES) at Subaru Telescope,15 which is the only instrument capable of imaging fed by AO in the Northern Hemisphere at the moment. In this paper, we present the current performance of high-contrast observations with VAMPIRES. The effective bandwidth of is narrower than the widths of broadband filters used in the optical-NIR astronomy,16,17 and thus investigating such emissions or absorption’s requires a specified narrowband filter or spectroscopic instrument with . VAMPIRES adopts a narrowband filter and details of the specifications are described in Sec. 2. Section 3 presents our engineering observations and the results. Finally, we summarize our work and briefly mention future prospects with AO upgrades in Sec. 4. 2.SCExAO + VAMPIRES SpecificationsThe VAMPIRES instrument15 is a module of the SCExAO instrument at the Subaru telescope.6,18,19 SCExAO, installed behind Subaru’s facility adaptive optics AO188, performs a second stage of wavefront correction using a 2000-element deformable mirror and a visible pyramid wavefront sensor (PyWFS). The control loop typically corrects the wavefront at a frequency of 2000 Hz. The NIR light (0.95 to ) typically goes through a coronagraph and is recorded using the integral field spectrograph CHARIS. In median seeing conditions, SCExAO provides extreme-AO performance with NIR Strehl ratios over 80%. In visible light (600 to 900 nm), the light not used by the PyWFS is sent toward the VAMPIRES module. Optical Strehl ratio’s with SCExAO depends on conditions (e.g., seeing, airmass, and brightness of a guide star) and we show examples of estimated Strehl ratios in our observations in Sec. 3.2. VAMPIRES is capable of performing diffraction limited, polarimetric imaging at visible wavelengths (600 to 800 nm). It uses two electron-multiplying CCD (EMCCD) cameras that in normal operation each record an orthogonal polarisation, which in combination with a ferroelectric liquid crystal modulator and half-waveplate allow precise polarimetric differential imaging (PDI). The high speed of the cameras (up to frames/s depending on subwindow size) allows lucky imaging techniques to be used to enhance resolution, and also include non-redundant masks for super-diffraction limited imaging. With the upgrade presented here, the polarisation-splitting optics can be automatically interchanged for wavelength-splitting optics, recording simultaneous images in a narrowband centered at (, ) in one camera and an adjacent continuum bandpass (, ) in the other. The filter information is summarized in Appendix A. The current field of view (FOV) of VAMPIRES is . Moreover, the choice of which of these filters is positioned in front of which camera can be rapidly switched during observation, to allow non-common path errors to be mitigated by a “double-difference” approach during data reduction (see Fig. 1 and the instrument papers for details6,15). The splitting of the light before encountering the filters is performed via a non-polarizing beamsplitter, to minimize mixing of polarization effects with spectral differential imaging (SDI; see Sec. 3)20 signal. 3.Science Verification3.1.Target SelectionFor science verification, we target omicron Ceti (omi Cet) and RY Tau. These targets are reported to have emissions. RY Tau is an intermediate-mass classical T Tauri Star (TTS) in the Taurus star-forming region (mass: , age: 4.5 Myr21). This TTS is known to eject a jet22,23 and the counterpart was imaged by SPHERE/zurich imaging polarimeter (ZIMPOL).21 A omi Cet is a Mira variable star, undergoing massive stellar pulsations wherein shocks are expected to produce emission.24 While detectable in spectroscopy, this is very difficult to resolve spatially due to the expected low spatial separation (several 10 s of milliarcseconds) between the star and shock region. We also use SAO 105500 ( Sge) data for a comparison of the post-processing results with those of omi Cet and RY Tau. Previous spectroscopic observation proves that this single star does not present any emission/absorption features25,26 and is good for the comparison of the results. 3.2.ObservationSCExAO is operated under angular differential imaging (ADI) mode27 by fixing the pupil, with which we can utilize a combination of SDI and the ADI technique to detect faint objects around the target star. VAMPIRES uses a beam-switcher where both filters can be converted frequently, and hence, the spectral content of the beams is switched between the two detectors. To reduce further bias, which arises from non-common path aberrations and systematic differences between the detectors, and to achieve better sensitivity, we utilize double differential imaging (DDI)28 techniques for SDI reduction (see also Figs. 2 and 3 for the schematic of the post-processing). To calibrate the plate scale, we imaged astrometric binaries HD 117902 and HIP 17954 and measured plate scale to be . We observed SAO 105500, omi Cet, and RY Tau in our engineering runs on May 22, 2019, September 8, 2019, and January 31, 2020 UT, respectively. Table 2 summarizes our observations used in this study and Table 3 summarizes the Strehl ratios of our data. We used the beginning part of these data sets for measuring them. To estimate the Strehl ratio we (1) computed the ratio between the total flux inside the core of the PSF ( in diameter) and the total flux of the PSF inside a circle of (to reject the diffraction pattern created by the quilting mode of the deformable mirror) and (2) computed the same ratio calculated for a simulated perfect PSF using the shape and orientation of the pupil. Then, the Strehl ratio is the flux ratio of the on-sky image divided by the flux ratio of the simulated image. The Strehl ratios measured from the single exposures indicate the performance of the “fast-AO correction” with SCExAO + VAMPIRES. For comparison, we also show the Strehl ratios with the long exposure (simply cube-combined PSF without image registration). We note that at the data reduction stage, we do image registration of each slice and then conduct the post-processing technique (see Sec. 3.3), the performance of which is indicated in the last column of Table 3. For the SAO 105500 and RY Tau data, we see the same characteristics in that the top 5% PSF has the highest Strehl ratio. The single exposure of RY Tau has lower signal-to-noise ratio (SNR) because this target is faint in the optical wavelength, which may affect the background evaluation and the Strehl ratio measurement. For the omi Cet data, the long-exposure PSF has the highest Strehl ratio, but this is likely related to measurement errors of the Strehl ratio and the background: we combined 3201 slices to make the long-exposure image (and slices to make the combined image) and the background values are much better estimated than the single-exposure images. Table 2Observing logs.
Table 3Strehl ratios.
aWe selected the single exposures whose PSFs have 5%, 30%, and 50% percentile peaks among all the single exposures using the fitted PSF information and then estimated the Strehls from these selected PSFs. This value indicates the performance of the short-exposure AO correction. bWe combined a data cube into an image without image registration. This value indicates the performance of the long-exposure AO correction (exposure time corresponds to the product of the single exposure time and the number of slices in the data cube, see also Table 2). Figure 3 shows difference between state 1 (cam1: continuum, cam2: ) and state 2 (cam1: , cam2: continuum) so that we can conduct the DDI technique to reduce the effects of the non-common path aberrations, which is explained in Sec. 3.3.1. The VAMPIRES output constitutes a data cube (, , and time) and exposure time/cube format information is summarized in Table 2. It is worth noting that we replaced an narrowband filter before the RY Tau observation and we observed SAO 105500 and omi Cet with a different filter (, ). 3.3.Data ReductionAs SCExAO + VAMPIRES enables fast-AO correction, we can obtain images with very short exposures. Then we can select “good” PSFs among all the data set like lucky imaging. After dark subtraction, we read all continuum slices, which do not basically include any asymmetric features related to from the central star, to fit PSFs for good-data selection and image registration. We used a criterion of fitted peak and selected 90% good data sets that would then be reduced by post-processing. The typical FWHMs of the selected data sets were 45 mas (7 pix) and 55 mas (8.5 pix) for omi Cet and RY Tau, respectively. Hereafter, we show several methods of reducing the data by combining the ADI and SDI techniques to look for differences in the outputs because, for instance, a previous VLT/spectrograph for integral field observations in the near infrared observation31 suggested a specific order to utilize ADI and SDI reduction techniques may change the overall sensitivity. 3.3.1.SDI and SDI + ADIThe advantage of the SDI reduction is that in principle we can subtract continuum components as a reference PSF from the image that includes both and continuum information. AO correction works with almost the same efficiency in both filter bands and enables us to simply subtract the continuum image from the image after correcting throughputs between cameras and filter transmission functions. The coefficients used for the throughput correction are assessed by comparing photometric results of instrumental laser PSFs. Figure 2 shows a flowchart of data reduction, and Fig. 3 shows a brief schematic of the double-SDI (dSDI) reduction with VAMPIRES, respectively. VAMPIRES data consist of two states where the and continuum filters are switched with each other. Subtracting an image taken at one of the detectors from the other image leaves non-common path aberrations, which corresponds to the bias () in Fig. 3. Applying the DDI technique to the SDI reduction can further suppress the effects of the bias on the final-reduced image. After PSF fitting of continuum slices using the Moffat function,32 we repeat producing an SDI-reduced slice by subtracting a good-continuum slice in the VAMPIRES data cube from a corresponding slice, which can attenuate the influence of the atmospheric turbulence at each short exposure. Here, we used the fitted peak of each PSF as a criterion for judging good PSFs. SDI reductionNext, we made a combined SDI-reduced image per data cube. As SCExAO is operated in ADI mode, we derotate images by differences of parallactic angle and then combine this data set into an SDI-reduced image. At each state, we conduct SDI reduction and finally obtain dSDI-reduced image using two SDI-reduced images. We note that in this study we mainly intend to reduce the continuum component from the image and that we do not scale the reference (continuum) image by the difference of wavelength from to attenuate the speckle noise. SDI + ADI reductionBy applying the ADI technique to the residual of the SDI result, we can further suppress the speckle noise. The data set of combined SDI-reduced image per data cube can also be applied to ADI reduction (see Sec. 3.3.2), which leads to two SDI + ADI images in state 1 and 2. We then conduct double-differential imaging to obtain the final dSDI + ADI image. 3.3.2.ADI + SDIADI makes a likely reference PSF that includes the starlight and instrumental speckles by rotating the FOV, then subtracting it from the raw images, and finally derotating and combining the subtracted images. This post-processing technique has been widely used for high contrast imaging and has been used to detect faint companions and/or other asymmetric features within a few arc sec. We made a set of images by combining selected good slices among one data cube, which is then input into ADI reduction algorithms. In this paper, we utilized Karhunen-Loéve Image Projection algorithms (KLIP)33 with pyKLIP algorithms34 to produce the most likely reference PSF from the set of combined SDI-reduced images, where we adopted optimization and subtraction area as large as the whole VAMPIRES FoV. After PSF fitting of continuum slices, we made both combined continuum and images per data cube. Then, we applied pyKLIP to four data sets (registered images of continuum/ in state 1/2). Each reduced image was then used for further dSDI reduction (see Fig. 3) and we finally got the ADI + dSDI image. We note that the ADI + SDI reduction substantially ignores the advantage of simultaneous acquisition of and continuum at each exposure. 3.4.ResultsWe present a variety of results that were reduced via SDI and ADI reduction techniques. We note that in this study, we do not analyze intensities of each detection and discuss mechanisms of (possible) emissions from omi Cet, omi Cet B, and RY Tau. 3.4.1.Omi CetFigure 4(a) shows a single exposure raw image of omi Cet. We note that omi Cet B was detected in both combined and continuum images from one data cube [see Figs. 4(b) and 4(c)]. Figures 4(d) and 4(e) compare the SDI-reduced images of state 1 and 2, respectively. Figure 4(f) shows the dSDI result, and Fig. 5 plots an azimuthally-averaged radial profile of the dSDI result. There is a ring-like feature at a separation of . We also checked encircled energy of both combined and continuum images, and profile is slightly brighter than the continuum profile at (see Fig. 6), though the difference is marginal compared with the and continuum observations of Carinae.35 This feature represents either of the expected astrophysical feature—limb brightening of the shock feature at —or the difference of PSFs at wavelengths between the and the continuum filters. To further test whether our data reduction can be affected by an artifact (e.g. different AO correction), we apply the dSDI reduction to the SAO 105500 data (see Sec. 3.4.3 for the result). A scientific analysis of these resolved observations of the shock region will be presented in a forthcoming paper. Figure 7 compares the outputs of combining ADI and dSDI reduction techniques. For ADI reduction, we adopted to show our outputs because we had a small number of data cubes and the larger KL number does not work properly. The smaller number of KL modes subtracts the starlight less efficiently and thus leaves a lot of residuals. Both of the reduction approaches resulted in almost the same outputs and detected omi Cet B with SNRs , but with the ADI + dSDI reduction [Fig. 7(b)], there still remains some stellar halo at the inner working angle. The noise was estimated by calculating the standard deviation within an annular region at different separations, which is used for signal-to-noise (SN) maps and detection limits. Figure 8 compares detection limits as a function of separation. The right vertical axis corresponds to apparent flux converted from contrast () assuming the -band flux for omi Cet. The humps at 0.4″ to 0.5″ seen in the limits of dSDI + ADI and ADI + dSDI are affected by the existence of omi Cet B. Regarding the throughput calculation to correct flux loss by the post-processing, we assumed that a companion can be detected in only wavelength and that SDI reduction does not lose the signal of . Therefore, we injected fake sources in the images and calculated the throughputs of ADI reduction. In case, a companion is detected in both continuum and filters, such as omi Cet B, it is better to use photometric results from both combined and continuum images to accurately obtain intensity. 3.4.2.RY TauFigure 9(a) shows a single exposure raw image of RY Tau. Figures 9(b) and 10(a) show SDI-reduced and ADI-reduced images of state 1. We note that RY Tau observation took only state 1, and we did not conduct the DDI reduction. Figures 10(c) and 10(e) compare the outputs of combining ADI and dSDI reduction techniques. For ADI reduction we adopted to show our outputs. Both of the reduction ways detected the jet with to 5, but its SNR is slightly higher in the SDI + ADI result [Fig. 10(c)]. Figures 10(b), 10(d), and 10(f) show cropped SN maps of Figs. 10(a), 10(c), and 10(e), respectively. Indeed a simple ADI reduction could detect the same feature to some extent as seen in the SDI + ADI image, but there is another feature that corresponds to speckles because of insufficient AO correction at optical wavelengths. The most significant feature in our post-processed image extends , which is consistent with the SPHERE/ZIMPOL observation.21 The SPHERE observation also reported a fainter and more extended region extending , and our SDI + ADI-reduced image marginally confirms the inner part () of this feature with . Figure 11 compares detection limits as a function of separation. At larger separations () ADI reduction achieved higher contrast than the combination of ADI and SDI reduction because subtracting continuum image (camera 1) from image (camera 2) leaves the bias that increases the background noise. At inner separations (), the detection limit of SDI + ADI looks worse than that of ADI + SDI, but this feature may be affected by higher SNR of the jet. From a point of view of contrast, the omi Cet observation (Fig. 8) achieved higher contrast than the RY Tau observation because of better wavefront sensing and AO correction, but RY Tau observation could achieve deeper detection limits in apparent flux. For future observations, the beam switching with VAMPIRES and DDI reduction will help to achieve a better contrast level than the RY Tau result. Compared with other high-contrast imaging observations, SCExAO + VAMPIRES has a similar sensitivity of to SPHERE/ZIMPOL,36,37 MagAO,7 and MUSE8 and provides great opportunities for high-contrast imaging in the Northern Hemisphere. 3.4.3.SAO 105500For comparing the post-processing results of the other two targets, we reduced the SAO 105500 data. We note that because of small field rotation, we could not conduct the ADI reduction and we show the SDI results in this section. Figures 12(a)–12(d) show the single image and the SDI-state1, SDI-state2, and dSDI results, respectively. We see the same tendency of the positive/negative counts at the central star at the SDI-reduced images in state 1/2 as the case of omi Cet [Figs. 4(d) and 4(e)]. The residual at the center probably reflects the difference of its spectrum at wavelengths of the -filter and the continuum-filter. Figure 13 shows an azimuthally-averaged radial profile of the surface brightness, and there is no ring-like feature as seen in the case of omi Cet [Fig. 4(f)]. Figure 14 compares difference of the encircled energies between and continuum PSFs. The slight rise in the SAO 105500 profile by at 0.3″ is likely caused by the difference of AO correction at and continuum wavelengths. The omi Cet profile has much greater difference by at 0.3″. Considering that AO correction to SAO 105500 works as effectively as to omi Cet, the difference profile at omi Cet may not only be affected by the difference of AO correction. We need to model the expected shock around omi Cet to discuss in detail as mentioned in Sec. 3.4.1. We also show the detection limits of the SAO 105500 data in Fig. 15. The humps at are affected by diffraction patterns arising from the bright central star. These detection limits reach similar contrast levels to the omi Cet case because of almost the same AO efficiency. 4.Summary and Future ProspectsWe present high-contrast observations with Subaru/SCExAO + VAMPIRES. VAMPIRES adopts the beam-switching system where we can efficiently conduct SDI reduction by utilizing DDI technique. We also show the combination of ADI reduction with SDI with our engineering data sets of omi Cet and RY Tau. Our dSDI reduction could resolve a ring feature around omi Cet (corresponding to the expected shock arising from this star’s pulsations) and detect omi Cet B in both continuum and filter, and SDI + ADI reduction could resolve a jet around RY Tau. We achieved at 0.5″ for omi Cet and at 0.5″ for RY Tau, respectively. Our detection limits in apparent flux are comparable to other high-contrast imaging with SPHERE/ZIMPOL, MUSE, and MagAO located in the Southern Hemisphere. Our instrument will provide great opportunities of implementing high-contrast explorations of northern targets. In the next few years, AO188 will benefit from two major upgrades that will benefit SCExAO and VAMPIRES. AO188’s 188-element deformable mirror will be replaced with a -element deformable mirror, which will improve significantly the wavefront correction at all wavelengths. The second upgrade is the addition of an NIR PyWFS inside AO188, which will be used to probe redder targets such as TTS.38 SCExAO is also being upgraded to perform PDI at NIR wavelengths, using a fast detector similarly to VAMPIRES, and also by doing spectro-polarimetry using CHARIS. A differential imaging mode is also envisioned to include an SDI mode at the () wavelength. In case of planet formation, for instance, theoretical models suggest that hydrogen emissions depend on several parameters such as number density of hydrogen, pre-shock velocity, extinction of the source, and filling factor of the emission39 and obtaining only cannot solve degeneracy between these parameters. Therefore will help to solve the degeneracies and promote detailed discussions of accretion mechanisms. Currently, a limited number of instruments enable high-contrast imaging explorations of (e.g., Keck/OH-suppressing infra-red imaging spectrograph40) and SCExAO will be more useful instruments for hydrogen emission observations. 5.Appendix A: Filter InformationFigure 16 summarizes the narrow-band filters we used in this study. The filter was replaced in January 2020. For high-contrast imaging with VAMPIRES, we designed the bandpass of the filter to be able to transmit sufficient signal in light of various broadening effects. For example, the maximum accretion velocity of a Jupiter mass planet is . To account for an object larger than a Jovian planet, we adopted a velocity of . In addition, the radial velocity (RV) motion of a planet around such a star is , and the RV motion of the star from the observer is . Therefore, we set a budget of 200 km/s, which corresponds to a 0.8-nm wavelength range at 600 nm, which should cover all the astrophysical features one may like to study. We found an off-the-shelf filter from Chroma that had specifications very close to our requirements (3-nm bandwidth; see also the manuscript webpage at Chroma41) and requested it be modified to have an FWHM bandwidth of 2 nm instead. This is still larger than the 0.8 nm needed and was chosen because of the uncertainty the manufacturer offered in the center wavelength of the filter and our ability to align it with respect to the beam. This filter was purchased and installed. However, the VLT/MUSE observation to study accretion from PDS 70 bc revealed that the effective width of is to .8,42 We found that detecting such a signal with the 2-nm bandwidth filter will require higher contrast, enough to detect the accreting planet. Therefore, we decided to replace the previous filter with a new filter (1-nm bandwidth) in January 2020. This bandwidth is the minimum acceptable value for the imaging with our assumptions. Out of band, the optical density (OD) of the new filter is larger than 4 (OD4 means that the out-of-band suppression is 0.01%) across 400 to 1200 nm, which covers the entire bandpass of the EMCCD. Similarly, the suppression of the old and continuum filters was better than OD5 (the out-of-band suppression is 0.001%) from 400 to 1000 nm. The detailed information for the new filter is shown at Alluxa.43 AcknowledgmentsWe would like to thank the anonymous referees for their constructive comments and suggestions to improve the quality of the paper. The authors are grateful to Steven P. Bos for helping us calculate the Strehl ratios. This research is based on data collected at the Subaru Telescope, which is operated by the National Astronomical Observatories of Japan. We acknowledge with thanks the variable star observations from the AAVSO International Database contributed by observers worldwide and used in this research. This research has made use of NASA’s Astrophysics Data System Bibliographic Services. This research has made use of the SIMBAD database, operated at CDS, Strasbourg, France. TU acknowledges JSPS overseas research fellowship and JSPS overseas challenge program for young researchers. The development of SCExAO was supported by JSPS (Grant-in-Aid for Research #23340051, #26220704, and #23103002), Astrobiology Center of NINS, Japan, the Mt Cuba Foundation, and the director’s contingency fund at Subaru Telescope. The authors wish to acknowledge the very significant cultural role and reverence that the summit of Mauna Kea has always had within the indigenous Hawaiian community. We are most fortunate to have the opportunity to conduct observations from this mountain. ReferencesJ. M. Beckers,
“Adaptive optics for astronomy: principles, performance, and applications,”
Ann. Rev. Astron. Astrophys., 31 13
–62
(1993). https://doi.org/10.1146/annurev.aa.31.090193.000305 Google Scholar
D. L. Fried,
“Statistics of a geometric representation of wavefront distortion,”
J. Opt. Soc. Am. (1917-1983), 55 1427
–1431
(1965). https://doi.org/10.1364/JOSA.55.001427 Google Scholar
R. Bacon et al.,
“The MUSE second-generation VLT instrument,”
Proc. SPIE, 7735 773508
(2010). https://doi.org/10.1117/12.856027 PSISDG 0277-786X Google Scholar
J. L. Beuzit et al.,
“SPHERE: the exoplanet imager for the Very Large Telescope,”
Astron. Astrophys., 631 A155
(2019). https://doi.org/10.1051/0004-6361/201935251 AAEJAF 0004-6361 Google Scholar
J. R. Males et al.,
“Magellan adaptive optics first-light observations of the exoplanet Pic B. I. Direct imaging in the far-red optical with MagAO + VisAO and in the near-IR with NICI,”
Astrophys. J., 786 32
(2014). https://doi.org/10.1088/0004-637X/786/1/32 Google Scholar
J. Lozi et al.,
“SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies,”
Proc. SPIE, 10703 1070359
(2018). https://doi.org/10.1117/12.2314282 PSISDG 0277-786X Google Scholar
K. Wagner et al.,
“Magellan adaptive optics imaging of PDS 70: measuring the mass accretion rate of a young giant planet within a gapped disk,”
Astrophys. J., 863 L8
(2018). https://doi.org/10.3847/2041-8213/aad695 Google Scholar
S. Y. Haffert et al.,
“Two accreting protoplanets around the young star PDS 70,”
Nat. Astron., 3 749
–754
(2019). https://doi.org/10.1038/s41550-019-0780-5 Google Scholar
S. M. Andrews et al.,
“The Disk Substructures at High Angular Resolution Project (DSHARP). I. Motivation, sample, calibration, and overview,”
Astrophys. J., 869 L41
(2018). https://doi.org/10.3847/2041-8213/aaf741 Google Scholar
R. Dong, J. R. Najita and S. Brittain,
“Spiral arms in disks: planets or gravitational instability?,”
Astrophys. J., 862 103
(2018). https://doi.org/10.3847/1538-4357/aaccfc ASJOAB 0004-637X Google Scholar
European Southern Observatory (ESO), “MUSE documentation,”
https://www.eso.org/sci/facilities/paranal/instruments/muse/doc.html Google Scholar
N. Zacharias et al.,
“VizieR online data catalog: UCAC4 catalogue (Zacharias+, 2012),”
(2012). Google Scholar
R. M. Cutri et al.,
“VizieR online data catalog: 2MASS all-sky catalog of point sources (Cutri+ 2003),”
(2003). Google Scholar
B. Norris et al.,
“The VAMPIRES instrument: imaging the innermost regions of protoplanetary discs with polarimetric interferometry,”
Mon. Not. R. Astron. Soc., 447 2894
–2906
(2015). https://doi.org/10.1093/mnras/stu2529 MNRAA4 0035-8711 Google Scholar
A. T. Tokunaga, D. A. Simons and W. D. Vacca,
“The Mauna Kea observatories near-infrared filter set. II. Specifications for a new ‘JHKLM’ filter set for infrared astronomy,”
Publ. Astron. Soc. Pac., 114 180
–186
(2002). https://doi.org/10.1086/338545 PASPAU 0004-6280 Google Scholar
M. Doi et al.,
“Photometric response functions of the sloan digital sky survey imager,”
Astrophys. J., 139 1628
–1648
(2010). https://doi.org/10.1088/0004-6256/139/4/1628 ASJOAB 0004-637X Google Scholar
N. Jovanovic et al.,
“The Subaru Coronagraphic Extreme Adaptive Optics system: enabling high-contrast imaging on solar-system scales,”
Publ. Astron. Soc. Pac., 127 890
(2015). https://doi.org/10.1086/682989 PASPAU 0004-6280 Google Scholar
T. Currie et al.,
“Performance and early science with the Subaru Coronagraphic Extreme Adaptive Optics project,”
Proc. SPIE, 11117 111170X
(2019). https://doi.org/10.1117/12.2529689 PSISDG 0277-786X Google Scholar
W. H. Smith,
“Spectral differential imaging detection of planets about nearby stars,”
Publ. Astron. Soc. Pac., 99 1344
–1353
(1987). https://doi.org/10.1086/132124 PASPAU 0004-6280 Google Scholar
A. Garufi et al.,
“SPHERE view of the jet and the envelope of RY Tauri,”
Astron. Astrophys., 628 A68
(2019). https://doi.org/10.1051/0004-6361/201935546 AAEJAF 0004-6361 Google Scholar
S. Cabrit et al.,
“Forbidden-line emission and infrared excesses in T Tauri Stars: evidence for accretion-driven mass loss?,”
Astrophys. J., 354 687
(1990). https://doi.org/10.1086/168725 Google Scholar
V. Agra-Amboage et al.,
“[O I] sub-arcsecond study of a microjet from an intermediate mass young star: RY Tauri,”
Astron. Astrophys., 493 1029
–1041
(2009). https://doi.org/10.1051/0004-6361:200810025 AAEJAF 0004-6361 Google Scholar
D. Gillet, E. Maurice and D. Baade,
“The shock-induced variability of the H alpha emission profile in Mira,”
Astron. Astrophys., 128 384
–390
(1983). AAEJAF 0004-6361 Google Scholar
G. A. Alekseeva et al.,
“The Pulkovo spectrophotometric catalog of bright stars in the range from 320 to 1080 nm. a supplement,”
Baltic Astron., 6 481
–496
(1997). https://doi.org/10.1515/astro-1996-0401 Google Scholar
M. Wittkowski et al.,
“Tests of stellar model atmospheres by optical interferometry. III. NPOI and VINCI interferometry of the M0 giant Sagittae covering 0.5–2.2 m,”
Astron. Astrophys., 460 843
–853
(2006). https://doi.org/10.1051/0004-6361:20065853 AAEJAF 0004-6361 Google Scholar
C. Marois et al.,
“Angular differential imaging: a powerful high-contrast imaging technique,”
Astrophys. J., 641 556
–564
(2006). https://doi.org/10.1086/500401 Google Scholar
S. Hinkley et al.,
“Speckle suppression through dual imaging polarimetry, and a ground-based image of the HR 4796A circumstellar disk,”
Astrophys. J., 701 804
–810
(2009). https://doi.org/10.1088/0004-637X/701/1/804 Google Scholar
Y. Huang et al.,
“Empirical metallicity-dependent calibrations of effective temperature against colours for dwarfs and giants based on interferometric data,”
Mon. Not. R. Astron. Soc., 454 2863
–2889
(2015). https://doi.org/10.1093/mnras/stv1991 MNRAA4 0035-8711 Google Scholar
American association of variable star observers (AAVSO), “AAVSO,”
https://www.aavso.org/ Google Scholar
V. Christiaens et al.,
“Separating extended disc features from the protoplanet in PDS 70 using VLT/SINFONI,”
Mon. Not. R. Astron. Soc., 486 5819
–5837
(2019). https://doi.org/10.1093/mnras/stz1232 MNRAA4 0035-8711 Google Scholar
A. F. J. Moffat,
“A theoretical investigation of focal stellar images in the photographic emulsion and application to photographic photometry,”
Astron. Astrophys., 3 455
(1969). AAEJAF 0004-6361 Google Scholar
R. Soummer, L. Pueyo and J. Larkin,
“Detection and characterization of exoplanets and disks using projections on Karhunen—Loève Eigenimages,”
Astrophys. J., 755 L28
(2012). https://doi.org/10.1088/2041-8205/755/2/L28 Google Scholar
J. J. Wang et al.,
“pyKLIP: PSF subtraction for exoplanets and disks,”
(2015). https://ui.adsabs.harvard.edu/abs/2015ascl.soft06001W/abstract Google Scholar
Y.-L. Wu et al.,
“Resolving the H-emitting region in the wind of Carinae,”
Astrophys. J., 841 L7
(2017). https://doi.org/10.3847/2041-8213/aa70ed Google Scholar
G. Cugno et al.,
“A search for accreting young companions embedded in circumstellar disks. High-contrast H imaging with VLT/SPHERE,”
Astron. Astrophys., 622 A156
(2019). https://doi.org/10.1051/0004-6361/201834170 AAEJAF 0004-6361 Google Scholar
A. Zurlo et al.,
“The widest H survey of accreting protoplanets around nearby transition disks,”
Astron. Astrophys., 633 A119
(2020). https://doi.org/10.1051/0004-6361/201936891 AAEJAF 0004-6361 Google Scholar
C. Z. Bond et al.,
“Adaptive optics with an infrared pyramid wavefront sensor,”
Proc. SPIE, 10703 107031Z
(2018). https://doi.org/10.1117/12.2314121 PSISDG 0277-786X Google Scholar
Y. Aoyama and M. Ikoma,
“Constraining planetary gas accretion rate from H line width and intensity: case of PDS 70 b and c,”
Astrophys. J., 885 L29
(2019). https://doi.org/10.3847/2041-8213/ab5062 Google Scholar
T. Uyama et al.,
“Constraining accretion signatures of exoplanets in the TW Hya transitional disk,”
Astron. J., 154 90
(2017). https://doi.org/10.3847/1538-3881/aa816a ASJOAB 0004-637X Google Scholar
CHROMA, “27001 - H-alpha 3nm bandpass,”
https://www.chroma.com/products/parts/h-alpha-3nm-bandpass Google Scholar
J. Hashimoto et al.,
“Accretion properties of PDS 70b with MUSE,”
Astron. J., 159 222
(2020). https://doi.org/10.3847/1538-3881/ab811e Google Scholar
Alluxa, “656.3-1 OD4 ultra narrow bandpass filter,”
https://www.alluxa.com/optical-filter-catalog/ultra-narrow-bandpass/656-3-1-od4-ultra-narrow-bandpass.html Google Scholar
Biography |