1.IntroductionThe Prime Focus Spectrograph (PFS)1 is an optical/near-infrared multifiber spectrograph with 2394 science fibers (Fig. 1), and is scheduled to be mounted on the Subaru 8.2-m telescope. The position of each fiber is controlled by a fiber positioner, called “Cobra,” consisting of two-staged piezo-electric rotary squiggle motors. Each fiber positioner unit samples a circular patrol region of 9.5-mm diameter at the telescope focal plane, and these positioners are arrayed into a hexagonal pattern with 8-mm central distances between adjacent positioners. The whole array extends to a single hexagonal field of view (FOV) whose effective diameter is 1.3 deg. The hexagonal FOV has an advantage for efficient tiling of survey areas, compared with e.g., a circular FOV. The fibers are divided into four groups, each of which enters one of the four spectrograph modules in a slit comprising 600 or 597 science fibers in a single row. Each spectrograph module has three color arms to cover a wide wavelength region from to , with a mean resolving power of 3000. This resolution is optimal for spectroscopic surveys of fainter galaxies and stars, targeting cosmology, Galactic archaeology and galaxy/AGN evolution. To simplify the design of the spectrograph, the beam from the telescope wide field corrector (WFC) is increased to by a microlens bonded to each fiber. A double Schmidt design is used for the spectrograph modules, which are at the fiber side and at the detector side. These apertures are slightly larger than the nominal , allowing for some focal ratio degradation (FRD) in the fiber. A medium spectral resolution mode with resolving power of 5000 for the red arms ( to ) is also included. This addition particularly benefits important Galactic archaeology studies. This new mode is realized by using a simple grating/grism exchange mechanism without changing any other design elements. The basic characteristics of PFS are summarized in Table 1. The total efficiency from the atmosphere to the detector is expected to be around ,1 depending on the wavelength and observing conditions such as telescope elevation and fiber position in FOV. Table 1Basic characteristics for Prime Focus Spectrograph (PFS).
Together, PFS and hyper suprime-cam (HSC)2 comprise the Subaru measurement of the images and redshifts project. PFS will accomplish the spectroscopic aspect of this project, and HSC has been implementing the imaging part since first light in 2012. The scientific case for the PFS surveys is described in an earlier paper.3 PFS has now entered the construction phase, and Fig. 2 shows the integration and test flow. Generally speaking, PFS comprises two main components: the prime focus instrument (PFI) and the spectrographs, with the fiber system connecting the two parts. This paper provides the first technical overview of the instrument, describing the essential components as well as their intensive test results. Further details on individual PFS components can be found in separate, component-specific SPIE conference papers viz.: fiber system,4–9 fiber positioner10 and prime focus instrument,11 spectrograph,12–14 Dewar and detector,15–18 and metrology camera.19 The subsystems are discussed in roughly the same order as the science light path through the instrument. The Subaru telescope and WFC focus light through a microlens; this microlens, which is described in Sec. 2.1, increases the of the beam to ease the design requirements on the spectrographs. The light then enters the multimode fibers, which are part of a fiber system described in Sec. 2.2 that also includes connectors and fiber arrays. In the telescope focal plane, these fibers are mounted in a series of positioners, described in Sec. 2.3, which connect the fibers to the celestial images. The fibers transmit the science light to one of the four spectrograph modules, described in Sec. 2.4. The spectrograph modules also provide a means for back-illumination, which enables the metrology camera system, described in Sec. 2.5, to measure the positions of the fibers. The relevant software and observational execution processes are described in Sec. 2.6. PFS technical first light is scheduled on Subaru in early 2018 with the start of the associated Subaru strategic program survey expected in 2019. The PFS collaboration is organized from Kavli IPMU (WPI) with PI Hitoshi Murayama and a PFS project office. Other members of the consortium include astronomers and engineers from Caltech/JPL, Princeton and JHU in the USA, LAM in France, USP/LNA in Brazil, and ASIAA in Taiwan. In 2014 January, NAOJ/Subaru formally joined the project, and MPA, Germany joined later in 2014. 2.Design and ProductionAlthough the detailed design of the instrument has been accomplished through a number of iterations, the most important initial optical parameters were based directly from the scientific case and basic technical constraints. The fiber core diameter of about was determined by the image scale at the prime focus provided through WFC and the typical target galaxy size. The numerical aperture, of the fiber, was constrained by the -ratio of the beam provided by WFC. The spectrograph -ratio of was constrained by the detector pixel size of for both the optical and near-infrared (NIR) arms. Since a large de-magnification factor is required to avoid oversampling the fiber core images, the fibers are separated into four distinct spectrograph modules in order to ensure the required imaging capability of each camera. These first-order constraints were complicated by both -ratio degradation of a fiber and WFC effects such as nontelecentricity and vignetting; together, these effects require the addition of a microlens on each fiber in the telescope focal plane to transform the input -ratio from 2.2 to 2.8. 2.1.MicrolensA glass-molded microlens, produced by Panasonic Industrial Devices Nitto, transforms the -ratio of the Subaru telescope plus WFC at prime focus into a slower -ratio of . This transformation eases the spectrograph design and also ensures an efficient light acceptance cone for each fiber. Glass molding is an attractive fabrication technique because it provides a wider selection of refractive indices than plastic molding and better uniformity of mechanical dimensions than polishing. We selected a high refractive index glass K-VC82 () for producing the 3-mm thickness microlenses with a 4.764-mm curvature-radius concave at the entrance surface (Fig. 3). A thickness of 3 mm was chosen as a tradeoff between manufacturing constraints and performance for extended targets. The measured thickness uniformity of mass-produced microlenses was within the specification of . The measured curvature radius and outer diameter of mass-produced microlenses were (1 sigma) and (1 sigma), respectively. The concave surface has been broad-band coated (reflectance between 380 nm and ) and overcoated with . The opposite flat side will be glued to a fiber. The excellent mechanical uniformity of the microlens enables passive alignment between the fiber and the microlens. We use a black zirconia fiber arm for integrating a fiber, a microlens and a fiber positioner motor shaft. 2.2.Fiber SystemThe fiber system consists of three components termed cables C, B, and A. Cable C is connected to the fiber positioners, capturing the science light in the telescope focal plane. Cable B allows this light to propagate through the telescope structure and building to a special room containing the spectrographs. Cable A is connected to the spectrographs. These cables are linked by two fiber connectors: one on the telescope spider and the other on each spectrograph module bench. This arrangement allows most of the total fiber lengths, cable B, to be permanently installed on the telescope. It permits the focal plane assembly to be removed so that other instruments can be mounted. Finally, it allows easier and safer installation of spectrograph modules and the system separability, as highlighted in Fig. 2. Furthermore, this arrangement simplifies future upgrades and flexibility; for example, a high resolution spectrograph could be realized relatively easily if desired, making use of the existing Cobra fiber positioners and all of the fixed fiber systems. Each cable is terminated with an assembly based on custom, 32-fiber, MTP connectors produced by US Conec, Ltd. On the telescope spider, cable B is connected to cable C using 22 USCONEC connectors in an assembly called the “tower connector”; four tower connectors are needed to connect all 2394 fibers. The tower connector is engineered to be particularly thin to meet challenging restrictions on size and shape at the prime focus. At the spectrograph end, cable B is connected to cable A using 12 USCONEC connectors in an assembly of eight so-called “gang connectors.” Fiber selection has been one of the key issues in the design of the fiber system. The fibers must have both excellent transmission across a wide spectral band (380–1260 nm) and low FRD properties. The project has intensively tested and evaluated fibers produced by two companies: a Japanese company Fujikura and a US company Polymicro. Two methods were used for the FRD measurements (Fig. 4). In the first method, as shown in Fig. 4(a), monochromatic light (filtered for 550 nm or He-Ne laser 633 nm) was input at the nominal PFS aperture, . In the second method, shown in Fig. 4(b), a collimated beam was input and scanned with the incident angle. Measurements showed that both fibers met system requirements for FRD and transmission. The Polymicro fibers were found to have a slightly better FRD performance. A Polymicro 50-m fiber had about 1% loss from FRD at , while a similar Fujikura 50-m fiber had about 3% loss. Fujikura fibers provide slightly better transmission: the gain depends on wavelength but is 2%–10% higher for a 50-m length. Based on the above results, we selected Polymicro fibers for cables C and A, and Fujikura fibers for cable B. Cable B is by far the longest run, so this ensures a high overall transmission. Cables A and C have tighter geometrical constraints and are, therefore, more susceptible to FRD losses making the Polymicro fiber the natural choice. In order to minimize geometrical losses at the connectors, the outer polyimide-buffer diameter of the fibers was specified as for Fujikura and for Polymicro. This ensures better center alignments between fibers at each USCONEC connector, whose hole diameter specification is . To further reduce light loss, we specified core (and clad) diameters as (), (), and (), respectively, for cables C, B, and A. This flow from a smaller core diameter to a larger core diameter () will minimize geometrical losses in a statistical way, even with slight misalignments of core centers between upstream and downstream fibers, as well as with the possibility of a few offset between the core center and buffer center. This intentional slight change of core diameters at the connectors will slightly affect the -ratio, but the effect of geometrical area matching at connectors will be more significant than that of the slight -ratio change. Both of Fujikura and Polymicro fiber productions have already been completed. To optimize uniformity of fiber image qualities, the mapping of fibers between the fiber positioner and the locations in the fiber slits has been carefully optimized. The focal plane has its best image quality near the center of the field and has a significant loss of telecentricity near the edge. Similarly, the spectrograph has better image quality near the center of the FOV. To balance these two effects, fibers from the edge of the telescopic FOV are routed to the inner location of a spectrograph slit, and fibers closer to the center of the telescopic FOV are routed to the outer location of the spectrograph slit. Such a fiber-routing pattern has been successfully designed, maintaining the modularities of fiber positioners and of spectrographs. 2.3.Fiber Positioner and Prime Focus InstrumentWe use fiber positioner units developed by JPL in partnership with New Scale Technologies. They consist of two-staged piezo-electric rotary squiggle motors arranged so as to place an individual fiber onto a target object within a particular patrol area on the focal plane. Intensive life time tests on such design-modified positioners are being carried out in 300 k cycles of clockwise plus counterclockwise rotations including hard stop events and some realistic movements at a temperature of , i.e., the most severe environment expected on Mauna Kea. Since open-loop positioning accuracy is insufficient, we carry out iterations based on the fiber position measured by a metrology camera, which is described in Sec. 2.5. Figure 5 shows an example of how the fiber position converges onto the target position for 100 randomly selected target points within the patrol area of 9.5-mm diameter. Intensive tests using 29 engineering model fiber positioners have been completed and we are now in the phase of mass production (Fig. 6). The fiber positioners are built into a module containing 57 positioners each with a microlensed fiber and the Cobra drive electronics. The total positioner system consists of 42 of these modules mounted onto the fiber-positioner optical bench, which is attached to the PFI structure. As shown in Fig. 1, the PFI is installed in Subaru’s housing structure, called prime focus unit POpt2, whose rotator provides PFI with the rotating part and the nonrotating part with respect to the telescope structure. While the nonrotating part is fixed to the telescope, rotation enables tracking target objects in the sky. A structure called the positioner frame connects the POpt2 rotator and the fiber-positioner optical bench on which fiber positioners as well as six acquisition and guide (A&G) cameras are mounted. For each of A&G cameras, we use FLI ML 4720, a frame transfer camera with pixels. Its coverage of on the sky is wide enough for providing at least one star for the A&G in a reasonable exposure time even in the lowest star-density area. Ninety-six fiducial fibers are mounted on this optical bench and provide the metrology camera with reference positions when they are artificially back-illuminated. For this purpose, the fiducial fiber illuminator is also located in the PFI rotating part. The cable wrapper ensures cables of fibers/electronics/coolant behave in a well-organized way when the rotator moves. A glass plate, called the field element, is attached to the fiber-positioner optical bench by three field element mounts. The thickness of the field element, 54 mm, roughly corresponds to the total thickness, 52 mm, of a HSC dewar window and a filter that are removed during the instrument exchange from the HSC to the PFS. The field element has an array of thin chrome-deposited dots at the surface closest to the image plane to enable better calibration. It is possible to obtain each pure fiber image or each pure spectrum on the spectrograph detectors by hiding some of fibers from calibration sources, such as a flat-field lamp and a wavelength calibration lamp. The dot size has been determined to be 1.5 mm, considering not only the geometrical obscuration at the distance of between the field element and tips of microlenses but also the open-loop accuracy of last fiber positioning. The production of the field element with dots has been completed. Calibration lamps are mounted on top of the PFI structure. To ensure the uniformity of lamp illumination, we will have a single flat-field lamp as well as wavelength calibration lamps (one for blue and another for red/near-infrared). These lamps illuminate a Lambertian flat-field screen attached at the bottom of the dome shutter. The desired irradiance pattern is obtained by using strongly aspheric plastic lenses in the illumination optics. Figure 7 summarizes all the above functions contained in the PFI. 2.4.SpectrographThe optical design of a double Schmidt-type spectrograph has been completed, with the wavelength range divided into three arms by two dichroic mirrors. Figure 8 shows one of the four such identical spectrograph modules. The slit structure at the entrance of each spectrograph module uses holes in front- and rear- thin electroformed nickel masks to define the fiber–fiber distances as well as their alignment. The arrangement is complicated by the requirement to allow for a nontelecentric slit plane. This requirement is driven by the 280-mm diameter limit on the grating fabrication. After developing prototype slit assemblies and measuring thermal effects on their stabilities, we are now completing the first final slit assembly. The production of the spectrograph optical elements is also in progress. All silica glass blanks are ready and being polished by Winlight System. Figure 9 shows an example of the precision optics required for the spectrographs. This thick optic meets our stringent requirements: radius of , a measured surface error peak-to-valley (P-V) for each beam footprint, and root mean square (RMS) surface roughness . Figure 10(a) shows one of the three prototype volume phase holographic (VPH) gratings produced by Kaiser. Although these are prototypes, they have qualities close to our specification: e.g., the RMS wavefront error for the blue VPH grating prototype was 250 nm for the 280-mm clear aperture, with a trefoil pattern as the dominant error source. We have recently identified the main cause of this trefoil pattern as a slight misalignment of optics for VPH production. This misalignment is now fixed and we are starting mass production of VPH gratings. Figure 10(b) shows an Ohara high-refractive-index prism blank made of S-LAH53 for a medium resolution grism in the red channel. Such a blank with high refractive index of and with a large size of 320-mm diameter has been successfully produced, realizing the homogeneity of P-V for the whole clear aperture when the spherical component is removed. This blank has been cut into two prisms, each of which will be glued to either side of a medium resolution VPH grating to form a medium resolution grism. The exchange between low resolution mode and medium resolution mode can be done remotely by using a slide-type exchanger of red gratings/grisms. For the red channel in each spectrograph module, we use a pair of Hamamatsu fully depleted charge-coupled devices (CCDs) with a pixel size of . This is exactly the same CCD used for the HSC. To simplify the control electronics system, mechanical interfaces, as well as operation on optical channels, a pair of -pixel Hamamatsu fully depleted CCDs is also used for the blue channel but with a thinner fully depleted region and a blue optimized coating. The depletion layer provides a smaller charge diffusion of about (1 sigma) compared with for a standard thickness of . The blue optimized coating provides a detector quantum efficiency of 57%, 74%, and 91% at 380, 400, and 500 nm, respectively, a significantly improvement over a standard coating. All the CCDs have been successfully produced. In collaboration with NAOJ Advanced Technology Center (ATC), AlN pin bases were prepared for individual optical CCDs by placing Ti pins with a positional accuracy in each of the , directions and a pin-diameter accuracy of . These pins allow accurate alignment of a pair of CCDs. For the NIR channel in each spectrograph module, a Teledyne H4RG-15 mercury-cadmium telluride device is used with the same pixel size of to the optical CCD case. The special cutoff wavelength of , as short as is feasible, suppresses the thermal background. The expected location for installing the spectrograph modules is the fourth floor of the infrared side (IR4) in the Subaru enclosure. The four spectrograph modules will lie within a single light-weighted spectrograph clean room, with thermal insulator walls to improve both temperature control and cleanliness. The temperature inside of the spectrograph clean room will be kept within . This thermal control stabilizes image quality and limits drift of image position to less than 0.2 pixel over 1 h. The optical bench for each spectrograph module is made of carbon fiber reinforced plastic (CFRP), which has a low coefficient of thermal expansion, further stabilizing the spectrograph optics configuration against residual temperature variation. The selection of CFRP has also been essential for reducing weight, as compared with stainless steel. The effects of possible vibrations have also been thoroughly investigated. For cooling the dewars and their enclosed detectors, we use Sunpower compact free-piston stirling cryocoolers. These have been selected because of cost and reliability; the mean time between failures (MTBF: the predicted elapsed time between inherent failures of a system during operation) is about 14 years. The vibration amplitude produced by the cryocooler is reduced, e.g., down to RMS level at the 60 Hz fundamental with an active damper. The project, however, has carefully designed the mechanical and optical components so that their resonance frequencies are larger than 85 Hz for all components when attached to the optical bench and are larger than the second harmonic (120 Hz) for internal modes except for the heaviest component cases, such as a grating/grism exchange mechanism. 2.5.Metrology CameraAs described in subsection 2.3, iteration is necessary to accurately position each fiber. To facilitate this iteration, the spectrograph is equipped with light emitting diodes that provide back-illumination when the spectrograph shutter is closed. These back-illuminated fibers are imaged by a metrology camera located at Cassegrain. The metrology camera is set in the common-use Cassegrain container,21,22 which has been developed in collaboration between the Kyoto tridimensional spectrograph II23,24 team and NAOJ. The container is installed with a robotic instrument exchanger Cassegrain instrument auto eXchanger for the Subaru telescope.25,26 Given the large distance between the fibers and the metrology camera, this configuration permits all fiber images to be viewed in one exposure. To validate the precision of this measurement, the “dome seeing” was measured at the Subaru telescope by using a similar configuration to back-illuminate Fiber Multi-Object Spectrograph27 fibers imaging with a commercial-based CCD camera Atik 450 set at the common-use Cassegrain container. To average out short-timescale variations in the perceived fiber positions due to “dome seeing,” an exposure time of around 1 s is optimal. Exposure times of 0.5 and 1.0 s lead to RMS image position variations of and , respectively. These variations are acceptably small compared to the final fiber positioning accuracy requirements of . The diameter of the metrology camera optics was chosen to minimize the effects of small surface deformations within the WFC optics. The optical path from the fiber plus microlens to the metrology camera is much narrower than the path from the telescope primary mirror to fiber plus microlens since the metrology camera aperture is much smaller than the primary mirror aperture (Fig. 11). This difference does not matter much if the WFC lens surface shapes are perfect, because the different paths share the same chief ray. The WFC lenses, however, have surface shape errors including high spatial frequencies around 6 mm with the P–V amplitude of 10–30 nm; these small errors are inherent to the manufacturing process that is required for the aspheric surfaces in the WFC. Such errors are allowed for the HSC imaging since the amplitude is much less than the wavelengths used. However, because the PFS metrology camera uses only a tiny portion of the WFC lenses for each fiber, the local slopes of the lenses produce significant deformation of coordinates of fibers in the focal plane when they are measured in the metrology camera coordinates. To suppress this effect down to the level of standard deviation of , an aperture diameter of 380 mm is required for the metrology camera; this diameter corresponds to the unobscured maximum aperture at Cassegrain. This large entrance pupil diameter would cause diffraction-limited images of the fibers to be undersampled, preventing accurate centroiding. To prevent this condition, the metrology camera optics were designed with a lot of spherical aberration, ensuring the point spread functions are uniform across the field and are several pixels in diameter. 2.6.Software and Execution Processes of ObservationsFor science operations, the observation preparation software parses large surveys into a series of individual observations, matches fibers to designated targets, selects appropriate guide stars, predicts observing times, and provides sequence files in a Subaru format. The PFS observation control computer (OBCP) controls the entire instrument under the Subaru observation management software Gen2. Execution of an observation begins with moving the telescope to the desired field center. While the telescope is slewing, the fiber positioning system executes commands from the OBCP to simultaneously move all fibers to their required positions with the real positions verified by the metrology system. With several iterations, the position error of each science fiber can be effectively minimized. In parallel with this process, the A&G system refines the pointing of the telescope and angle of the instrument rotator. The hexapod is commanded to move to the appropriate position to maintain the WFC alignment in the presence of flexure in the POpt2 structure. Once positioning is complete, autoguiding commences. The onsite data reduction system produces quick-look information on the completed observation so that data quality and survey progress can be monitored. The collected raw data will be transferred to and archived in the Subaru telescope archive system data archive system, which then provides data retrieval for further scientific data reduction and analysis. 3.SummaryFollowing the successful project conceptual design review and preliminary design review and further subsystem critical design reviews, PFS has now entered the construction phase. Mass production of the microlenses and fibers is complete. These two components are now being integrated, which includes gluing them in the fiber arm structure. Later, they will be integrated with each fiber positioner, shortly to enter the mass production phase, by gluing the fiber arm to the positioner motor shaft. The positioner modules will be integrated onto the positioner optical bench and then into the PFI structure. This integrated PFI system will be tested together with the metrology camera. For the spectrograph module side, all optical elements, including gratings, are in production. These optical components will be integrated with cryostats and dewars on four spectrograph optical benches. After acceptance tests of each of the PFI and spectrograph components, they will be transported to Hawaii, where the whole system finally will be tested all together: the PFI system in the POpt2 at the telescope top, spectrograph modules in a single clean room on the fourth floor IR side, and the metrology camera in the Cassegrain container. The technical first light is planned in early 2018. AcknowledgmentsWe gratefully acknowledge support from the Funding Program for World-Leading Innovative R&D on Science and Technology (FIRST) program “Subaru Measurements of Images and Redshifts (SuMIRe),” CSTP, Japan, and Fundação de Amparo a Pesquisa do Estado de São Paulo (FAPESP), Brazil. We appreciate staff members at Subaru Telescope for continuously supporting our activities. We thank NAOJ ATC staff members, particularly Tetsuo Nishino, Norio Okada, and Yukiko Kamata, for preparing AlN pin bases, and Durham University staff members for their consultancy to IPMU on the fiber system. We also acknowledge the WFMOS-B team whose accumulated efforts of many years have inspired us. This paper has been revised and updated, for the purpose of journal publication, from the PFS overview paper28 presented in an SPIE conference. ReferencesH. Sugai et al.,
“Prime Focus Spectrograph: Subaru’s future,”
Proc. SPIE, 8446 84460Y
(2012). http://dx.doi.org/10.1117/12.926954 PSISDG 0277-786X Google Scholar
S. Miyazaki,
“Hyper suprime-cam for weak gravitational lensing survey (presentation video),”
Proc. SPIE, 9143 91431Z
(2014). http://dx.doi.org/10.1117/12.2063486 PSISDG 0277-786X Google Scholar
M. Takada et al.,
“Extragalactic science, cosmology, and Galactic archaeology with the Subaru Prime Focus Spectrograph,”
Publ. Astron. Soc. Jap., 66
(1),
(2014). http://dx.doi.org/10.1093/pasj/pst019 PASJAC 0004-6264 Google Scholar
N. Takato et al.,
“Design and performance of a F/#-conversion microlens for prime focus spectrograph at Subaru telescope,”
Proc. SPIE, 9147 914765
(2014). http://dx.doi.org/10.1117/12.2056888 PSISDG 0277-786X Google Scholar
A. C. de Oliveira et al.,
“Fiber optical cable and connector system (FOCCoS) for PFS/Subaru,”
Proc. SPIE, 9151 91514G
(2014). http://dx.doi.org/10.1117/12.2056888 PSISDG 0277-786X0277-786X Google Scholar
J. B. dos Santos,
“Studying focal ratio degradation of optical fibers for Subaru's Prime Focus Spectrograph,”
Proc. SPIE, 9151 915150
(2014). http://dx.doi.org/10.1117/12.2056460 PSISDG 0277-786X Google Scholar
A. C. de Oliveira et al.,
“Slit device for FOCCoS PFS Subaru,”
Proc. SPIE, 9151 91514D
(2014). http://dx.doi.org/10.1117/12.2056400 PSISDG 0277-786X Google Scholar
A. C. de Oliveira et al.,
“Polish device for FOCCoS/PFS slit system,”
Proc. SPIE, 9151 915145
(2014). http://dx.doi.org/10.1117/12.2056047 PSISDG 0277-786X Google Scholar
A. C. de Oliveira et al.,
“Multi-fibers connectors systems for FOCCoS-PFS-Subaru,”
Proc. SPIE, 9151 915160
(2014). http://dx.doi.org/10.1117/12.2055888 PSISDG 0277-786X Google Scholar
C. D. Fisher et al.,
“Developing engineering model Cobra fiber positioners for the Subaru Telescope’s prime focus spectrometer,”
Proc. SPIE, 9151 91511Y
(2014). http://dx.doi.org/10.1117/12.2054700 PSISDG 0277-786X Google Scholar
S.-Y. Wang et al.,
“Prime focus instrument of prime focus spectrograph for Subaru telescope,”
Proc. SPIE, 9147 91475Q
(2014). http://dx.doi.org/10.1117/12.2057247 PSISDG 0277-786X Google Scholar
S. Vivès et al.,
“Current status of the spectrograph system for the SuMIRe/PFS,”
Proc. SPIE, 9147 914762
(2014). http://dx.doi.org/10.1117/12.2056401 PSISDG 0277-786X Google Scholar
S. Pascal et al.,
“Optical design of the SuMiRe/PFS Spectrograph,”
Proc. SPIE, 9147 914747
(2014). http://dx.doi.org/10.1117/12.2055738 PSISDG 0277-786X Google Scholar
F. Madec et al.,
“Integration and test activities for the SUMIRE prime focus spectrograph at LAM: first results,”
Proc. SPIE, 9147 91475Z
(2014). http://dx.doi.org/10.1117/12.2056577 PSISDG 0277-786X Google Scholar
M. Hart et al.,
“Focal plane alignment and detector characterization for the Subaru prime focus spectrograph,”
Proc. SPIE, 9154 91540V
(2014). http://dx.doi.org/10.1117/12.2057558 PSISDG 0277-786X Google Scholar
S. Hope et al.,
“CCD readout electronics for the Subaru prime focus spectrograph,”
Proc. SPIE, 9154 91542G
(2014). http://dx.doi.org/10.1117/12.2057166 PSISDG 0277-786X Google Scholar
R. H. Barkhouser et al.,
“Volume phase holographic gratings for the Subaru prime focus spectrograph: performance measurements of the prototype grating set,”
Proc. SPIE, 9147 91475X
(2014). http://dx.doi.org/10.1117/12.2057337 PSISDG 0277-786X Google Scholar
J. E. Gunn et al.,
“The near infrared camera for the Subaru prime focus spectrograph,”
Proc. SPIE, 9147 91472V
(2014). http://dx.doi.org/10.1117/12.2057136 PSISDG 0277-786X Google Scholar
S.-Y Wang et al.,
“Metrology camera system of prime focus spectrograph for Subaru telescope,”
Proc. SPIE, 9147 91475S
(2014). http://dx.doi.org/10.1117/12.2055787 PSISDG 0277-786X Google Scholar
A. C. de Oliveira et al.,
“FOCCoS for Subaru PFS,”
Proc. SPIE, 8446 84464R
(2012). http://dx.doi.org/10.1117/12.925745 PSISDG 0277-786X Google Scholar
H. Sugai et al.,
“Test observations of the Kyoto tridimensional spectrograph II at University of Hawaii 88-inch and Subaru telescopes,”
Proc. SPIE, 5492 651
–660
(2004). http://dx.doi.org/10.1117/12.550987 PSISDG 0277-786X Google Scholar
H. Sugai et al.,
“The Kyoto tridimensional spectrograph II: progress,”
Proc. SPIE, 4008 558
–569
(2000). http://dx.doi.org/10.1117/12.395514 PSISDG 0277-786X Google Scholar
H. Sugai et al.,
“The Kyoto tridimensional spectrograph II on Subaru and the University of Hawaii 88 in telescopes,”
Publ. Astron. Soc. Pac., 122 103
–118
(2010). http://dx.doi.org/10.1086/648997 PASPAU 0004-6280 Google Scholar
H. Sugai et al.,
“The Kyoto tridimensional spectrograph II,”
Proc. SPIE, 3355 665
–674
(1998). http://dx.doi.org/10.1117/12.316800 PSISDG 0277-786X Google Scholar
T. Usuda et al.,
“CIAX: Cassegrain instrument auto exchanger for the Subaru telescope,”
Proc. SPIE, 4009 141
–150
(2000). http://dx.doi.org/10.1117/12.388384 PSISDG 0277-786X Google Scholar
K. Omata et al.,
“Control of the Subaru telescope instrument exchanger system,”
Proc. SPIE, 4009 374
–385
(2000). http://dx.doi.org/10.1117/12.388409 PSISDG 0277-786X Google Scholar
M. Kimura et al.,
“Fibre multi-object spectrograph (FMOS) for the Subaru telescope,”
Publ. Astron. Soc. Jap., 62 1135
–1147
(2010). http://dx.doi.org/10.1093/pasj/62.5.1135 PASJAC 0004-6264 Google Scholar
H. Sugai et al.,
“Progress with the prime focus spectrograph for the Subaru telescope: a massively multiplexed optical and near-infrared fiber spectrograph,”
Proc. SPIE, 9147 91470T
(2014). http://dx.doi.org/10.1117/12.2054294 PSISDG 0277-786X Google Scholar
BiographyHajime Sugai received his doctor degree (astronomy) from the University of Tokyo in 1993. From 1996, as an assistant professor of Kyoto University, he researched active phenomena in galaxies and also developed Kyoto tridimensional spectrograph II, which has integral field spectrograph and Fabry-Perot modes. He has been an associate professor of Kavli IPMU (WPI), the University of Tokyo, since 2011. He has worked as the PFS project manager. |