Open Access
1 September 2010 Heart wall velocimetry and exogenous contrast-based cardiac flow imaging in Drosophila melanogaster using Doppler optical coherence tomography
Author Affiliations +
Abstract
Drosophila melanogaster (fruit fly) is a central organism in biology and is becoming increasingly important in the cardiovascular sciences. Prior work in optical imaging of the D. melanogaster heart has focused on static and dynamic structural anatomy. In the study, it is demonstrated that Doppler optical coherence tomography can quantify dynamic heart wall velocity and hemolymph flow in adult D. melanogaster. Since hemolymph is optically transparent, a novel exogenous contrast technique is demonstrated to increase the backscatter-based intracardiac Doppler flow signal. The results presented here open up new possibilities for functional cardiovascular phenotyping of normal and mutant D. melanogaster.

1.

Introduction

Over the past decade, there has been considerable growth in the literature focusing on the cardiovascular biology of Drosophila melanogaster. In particular, this research has focused on cardiovascular development1 and on using D. mela-nogaster as a model for human cardiovascular disease.2 Two main categories of innovations have driven this research. First, genetic and genomic technologies continue to increase in sophistication. Examples include the availability of deletion collections with high-resolution genomic coverage3 and gene expression microarrays.4 Second, there are a growing number of nonimaging and imaging technologies that allow for qualitative and quantitative assessment of D. melanogaster heart function. These techniques range from invasive point measurements of heart electrical activity5 to direct optical imaging of dynamic heart anatomy.5, 6, 7, 8, 9

Structural optical coherence tomography (OCT) has been previously employed to investigate the dynamic heart function of D. melanogaster.6, 7, 10 This work builds on prior experience with OCT in vertebrate cardiovascular embryonic imaging.11, 12, 13, 14, 15, 16, 17, 18, 19 In addition to focusing on static and dynamic heart anatomy, some of these vertebrate studies imaged blood flow using Doppler OCT.12, 15, 18 The scattering-related Doppler signal exploited in these studies was generated by endogenous scatterers, i.e., red blood cells. D. melanogaster, however, relies on an extensive tracheal system for oxygen delivery20, 21 and, therefore, does not have red blood cells in its circulatory fluid or hemolymph. In fact, the adult hemolymph is relatively transparent when imaged using OCT.6, 7 Therefore, exogenous agents are required to perform Doppler-based flow imaging. Being able to perform flow imaging would be useful for detailed phenotyping of normal and mutant D. melanogaster cardiovascular physiology. In addition, flow imaging has the potential to study flow reversal (Fig. 1 ). Flow reversal is a normal occurrence in D. melanogaster and occurs when the heart switches from anterograde contractions to retrograde contractions or vice versa.22 The specific physiological role of flow reversal in D. melanogaster is incompletely understood and, as such, is an active area of investigation.23 In particular, it is unclear whether heartbeat reversal in D. melanogaster drives shifts in hemolymph volume between body segments to influence tracheal ventilation as it does in insects such as adult butterflies.23 Prior research efforts into the mechanisms behind and physiologic role of flow reversal have focused on heart wall motion22, 23, 24 and not directly on flow itself.

Fig. 1

Schematic of the heart (h) and proximal aorta (ao) in adult D. melanogaster.30 Direction of hemolymph inflow through ostia (o) and outflow through the aorta (ao) is indicated by the dashed gray arrows. The heart is located in the abdomen, and the aorta originates near the junction of the abdomen and thorax. OCT imaging in this study focused on the conical chamber (cc), the most anterior portion of the heart. An anterograde beat is characterized by posterior-to-anterior contraction of the heart, while a retrograde beat is characterized by anterior-to-posterior contraction of the heart.

056020_1_053005jbo1.jpg

In addition to providing information regarding cardiovascular flow, Doppler-based imaging can provide information about heart wall motion. In clinical cardiology, heart wall velocimetry using ultrasound imaging25 can be used obtain information about systolic and diastolic function.26 Doppler wall velocimetry using OCT may therefore provide similar information in the imaging of small cardiovascular systems such as D. melanogaster and developing embryos. In this study, we demonstrate the feasibility of using Doppler OCT for quantitatively studying cardiac flow and wall motion in adult D. melanogaster. Two sets of results are presented here. First, B- and M-mode Doppler OCT were used to perform heart wall velocimetry in wild-type adult D. melanogaster hearts. Second, intracardiac Doppler OCT flow imaging was achieved by introducing scattering polystyrene microspheres into the open circulation using a novel microinjection technique.

2.

Methods

2.1.

D. melanogaster Culture, Anesthesia, and Immobilization

Flies (OreR) were raised at 24°C and fed an instant food media (Carolina Biological Supply Company, Burlington, North Carolina). For contrast injection and imaging, flies were anesthetized with FlyNap (Carolina Biological Supply Company). FlyNap is a volatile mixture of triethylamine (50%), ethanol (25%), and fragrance (25%). After anesthesia, flies were immobilized by taping their wings to a glass slide.

2.2.

OCT System and Imaging

OCT imaging focused on the conical chamber of the heart (Fig. 1). The principles and operation of the phase-sensitive OCT system used has been previously described.27 Briefly, this optical frequency domain–type OCT system employed a swept laser source with a semiconductor optical amplifier gain medium and a scanning polygon-based wavelength filter. The system operates at a center wavelength of 1300nm and has an axial resolution of 10μm in air. Imaging was performed at A-line rates of 10kHz . The sample arm optics have a predicted lateral resolution of 16μm .

This OCT system tracks the phase-sensitive time-domain signal by calculating the change between successive A-scans in the phase of the fast Fourier transform of the wave number–domain spectral interferogram. As previously described,27, 28 swept laser sources with a mechanical wavelength-tuning element have an intrinsic source of phase instability in that each sweep of the laser has a slightly different starting wave number. In order to correct for this, the phase of an independent stationary sample mirror was recorded in order to establish a zero-phase point when calculating the phase difference on successive A-scans.27 Doppler shifts (fd) were converted to velocity (v) using the usual Doppler equation [ fd=2vcos(θ)nνc ; θ , Doppler angle; n , tissue optical index; ν , optical frequency; c , free-space vacuum speed of light].

2.3.

Exogenous Contrast

A novel microinjection technique was used to visualize intracardiac flow (Fig. 2 ; Video 1 ). Using a micropipette puller, glass capillary tubes (outer diameter 1mm ) were tapered and then cleaved on a rough surface to a final tip outer diameter of 100μm . Next, 830-nm red polystyrene beads (Bangs Laboratories, Fishers, Indiana) were diluted 3:1 with normal saline. The contrast solution was formulated immediately prior to injection. Particle uniformity was ensured by thoroughly mixing the solution by repeated intake into and ejection from a micropipette tip over the course of 1min . Injections were performed under a standard stereomicroscope. After manually introducing a contrast agent-filled micropipette into the thorax, contrast was injected by applying 3psi of pressure applied over 30ms using a nitrogen-based pressure injection system. Exogenous injection was performed using light stereomicroscopy guidance. OCT imaging was performed a few minutes after injection.

Fig. 2

Intraluminal Doppler OCT imaging using exogenous scattering contrast agents. Panel (a) is a still frame taken from Video 1 and shows the microinjection technique. Panel (b) is a structural OCT image of the heart during systole a few minutes after injection of contrast agent into the thorax. Panel (c) has the Doppler OCT image superimposed on the structural OCT image. The Doppler angle is estimated to be 110deg . Also clearly seen in panel (c) is the Doppler signal generated by the ventral wall.

056020_1_053005jbo2.jpg

Video 1

Injection of exogeneous scattering contrast particles. The first 15s of the video show microinjection of the particles into the thorax. The last 3s focus on the heart of the same animal after injection. The heart can be readily identified by red particles that have adhered to its lumen. (Color online only.) (QuickTime, 3.26 MB) .

056020_1_053005jbov1.jpg
10.1117/1.3503418.1

2.4.

Image Processing

Images were acquired using custom-designed LabView (National Instruments, Austin, Texas) software. MATLAB (MathWorks, Natick, Massachusetts) and ImageJ29 were used for advanced processing. Doppler signal from areas of low backscatter intensity (e.g., air, transparent fluid) was rejected based on pixel intensity in structural images.

3.

Results

Figure 3 shows B-mode structural and Doppler OCT images as the heart completes one cycle of contraction (i.e., systole) and relaxation (i.e., diastole). An anterograde (i.e., posterior to anterior) beat22 is shown. Prior to contraction, there was no organized Doppler signal from the heart wall. During systole, the Doppler signal on the ventral wall clearly traveled from the posterior to anterior aspect of the heart chamber. Futhermore, prior to discernable change in heart chamber diameter, a positive Doppler signal was detected from the posterior aspect of the ventral heart wall. Peak ventral wall velocity in Fig. 2 was 1μmms (1mms) . It was assumed that wall motion was parallel to the direction of sample arm OCT beam propagation. Given a measured dorsal–ventral diastolic diameter of 100μm in this individual fly, the wall velocity normalized to chamber diameter was 10 chamber diameters per second. During systole, the Doppler signals from the ventral and dorsal walls had opposite signs, indicating that the heart wall was moving oppositely. During diastole, the direction of heart wall relaxation was also in a posterior-to-anterior direction. The magnitude of the ventral wall’s Doppler signal during diastole was slightly less than the magnitude during systole.

Fig. 3

High temporal resolution structural and Doppler OCT imaging (40 frames per second) of dynamic anatomy and heart wall velocity during an anterograde (posterior-to-anterior) heart beat in D. melanogaster. Also note that the lumen during systole generated very little backscatter-related signal, and as a consequence, there is essentially no flow-related Doppler signal.

056020_1_053005jbo3.jpg

Figure 4 shows an M-mode structural and Doppler OCT image of the heart during systole. By using M-mode imaging at an A-scan rate of 10kHz , measurement of wall velocity was obtained in the millisecond regime. The time-varying ventral and dorsal heart wall velocities during systole are plotted. The ventral wall velocity magnitude was slightly larger than that of the dorsal wall velocity. The integrated velocities for each wall corresponded to the total measured change in dorsal–ventral chamber diameter. The total measured change corresponds to the difference between the manually measured end-diastolic diameter (EDD) and the end-systolic diameter (ESD) of the heart lumen along the dorsal–ventral axis.

Fig. 4

Dorsal and ventral heart wall velocity (left panel) during systole as measured using M-mode Doppler OCT (lower-right panel). These representative velocity curves were obtained by plotting the maximum (ventral wall) or minimum (dorsal wall) wall velocity at each time point (i.e., M-mode line) from a manual region of interest drawn on each heart wall. Red curves are ventral data, and blue curves are dorsal data. Solid curves represent velocity data, while dashed curves represent displacement (i.e., integrated velocity) data. The upper-right panel shows the equations governing change in chamber diameter measured using structural OCT and calculation of displacement using Doppler velocimetry data. The structural OCT image is shadowed over the Doppler M-mode image. The red/blue (i.e., positive/negative Doppler shift) color map used here is distinct from that used in the other figures and has a very limited dynamic range in order to accentuate the sign, as opposed to the magnitude, of the Doppler shift. EDD, end-diastolic diameter; ESD, end-systolic diameter; vv(t) , time-varying ventral wall velocity; vD(t) , time-varying dorsal wall velocity.

056020_1_053005jbo4.jpg

As discussed earlier and as evident from Figs. 3 and 4, adult D. melanogaster hemolymph is essentially transparent. Its transparency is related to its low fractional particle volume (i.e., percent volume of a fluid mixture that is a cell or another kind of particle). The fractional particle volume can in principle be increased by introduction of microparticles into the circulatory flow. Since hemolymph in the extracellular–extravascular space (e.g., hemocoel) flows into the heart via ostia (Fig. 1), any particle injected into the extracellular–extravascular space should flow into the heart, provided that the particle is smaller than the ostia diameter. Since ostia in the adult D. melanogaster have a diameter of 10μm (Ref. 30), microparticles should readily pass into the heart. This was confirmed experimentally (Fig. 2; Video 1). Video 1 is a 15-fps video recording of microparticle microinjection. After introduction of the micropipette into the thorax and injection of the particles, a “blush” of red was seen at the presumed location of the heart just posterior to the thorax–abdomen junction. The distribution and flow of particles appeared directed and not isotropic. After several seconds, the blush cleared. Zooming in on the heart, there was a faint red outline of the heart due to microparticles sticking presumably to the lumen of the heart. As a secondary confirmation of this mode of contrast delivery in the adult D. melanogaster cardiovascular system, red dye (McCormick and Company, Sparks, Maryland) injected into the thorax localized to the heart as observed on video microscopy (Video 2 ).

Video 2

Thoracic injection of an absorptive red dye. Immediately after injection, a “blush” of dye can be seen in the heart. (QuickTime, 670 KB) .

056020_1_053005jbov2.jpg
10.1117/1.3503418.2

Structural OCT imaging, performed a few minutes after injection, showed significant intracardiac backscatter signal (Fig. 2), demonstrating that OCT can detect backscatter from a steady-state concentration of microparticles, long after the color of the microparticle is no longer visible in the hemolymph by light microscopy. This backscatter signal enabled intraluminal flow imaging using Doppler OCT. The presence of Doppler signal of significant magnitude corresponded with the onset of wall motion as indicated by wall Doppler signal. The flow-related Doppler signal during systole had a negative sign, indicating an anterograde (i.e., posterior-to-anterior) flow. For comparison, note the relative absence of OCT Doppler signal in the heart lumen in the absence of exogenous contrast (Figs. 3 and 4). Overall, seven OCT-confirmed and one video microscopy–confirmed injections of microparticles were successfully completed.

Figure 5 shows an extended M-mode recording that demonstrates the phenomenon of cardiac reversal.22 During cardiac reversal, the direction of the heart contractions reverse. Over the course of the 2.16-s M-mode image in Fig. 5, the heart transitioned from anterograde contraction to asystole to retrograde (i.e., anterior-to-posterior) contractions. As in Fig. 2, flow generated by anterograde contractions generated a Doppler shift with a negative sign. During asystole, there was no significant intraluminal or heat wall Doppler signal. During retrograde contractions, the flow-generated Doppler shift had a positive sign, indicating anterior-to-posterior flow. These results indicate that flow direction can be determined with a one-dimensional spatial flow measurement, whereas heart wall Doppler imaging requires a two-dimensional Doppler measurement (Fig. 3). Figure 5 shows the first systolic event after the 1.375-s asystolic period, while Fig. 5 is a plot of the midline intraluminal flow velocity taken over a narrow rectangular region of interest, with each time point representing an average over the spatial dimension of the region of interest. Rapid flow acceleration on the order of 0.1μmms2 (2μmms20ms) could be estimated from the flow profile.

Fig. 5

Intracardiac M-mode Doppler flow imaging several minutes after the injection of exogenous contrast material. Panel (a) shows an extended M-mode recording that captures cardiac reversal. Flow related to anterograde beats generated a negative Doppler shift, while flow related to retrograde beats generated a positive Doppler shift. Systole (s) was determined by the presence of a positive Doppler shift on the ventral heart wall. Panel (b) shows the first retrograde systolic event after asystole, while panel (c) shows the midline velocity profile from (b). Both (a) and (b) have a height of 250μm .

056020_1_053005jbo5.jpg

Formal survival studies after microinjection were not performed. However, in our initial experience with eight flies with imaging-confirmed injection of a scattering contrast agent, flies would live for a few to several hours after injection of the polystyrene microspheres.

4.

Discussion

The proof-of-principle results shown here represent the first use of Doppler OCT to quantify cardiovascular function in the adult D. melanogaster. Heart wall velocimetry is readily accomplished in the millisecond regime. This is important because the time constant of cardiovascular mechanics are on the order of milliseconds. The open circulatory physiology of this animal is exploited to deliver, in a straightforward manner, scattering contrast agents into the heart, thereby enabling Doppler OCT flow imaging. Moreover, during an anterograde beat, ventral heart wall and intraluminal Doppler signal are readily distinguished from each other.

Doppler OCT thus has the potential to enhance the use of adult D. melanogaster as a model of cardiovascular disease. Prior imaging studies have relied on phenotypes (e.g., heart rate, fractional shortening) derived from direct observation and from dynamic structural heart parameters (e.g., end-diastolic and end-systolic diameters).5, 6, 9, 10 Through phase-sensitive detection and processing, the repertoire of cardiovascular phenotypes for genetic screens can be expanded to include heart wall velocity and intracardiac flow velocity. Future work on contrast imaging will address three limitations in the present study. First, anesthesia may have direct cardiac effects, and our work has shifted to the prepupal stage when the organism is immobile and anesthesia is not required for cardiac imaging. Second, the increased fractional particle volume of contrast-enhanced hemolymph can increase the hemolymph viscosity. Therefore, future work will focus on minimizing the injected volume of contrast agent while maintaining sufficient backscatter signal for Doppler imaging. Third, intraluminal and heart wall Doppler signal can be difficult to distinguish when they are of the same sign. Differentiation between the two could potentially be made based on the standard deviation of the Doppler signal.31

In this and prior7 studies, the heart wall speckle pattern is relatively static when the heart is at rest but varies rapidly during contraction and relaxation. Such variations in speckle influences the signal-to-noise ratio of the heart wall Doppler signal.32 Although spatial and temporal averaging can improve the signal-to-noise ratio in this context, such prominent variations in speckle can be potentially utilized for heart wall elastography using previously described methods (see, for example, Ref. 33).

In addition to its importance in the study of heart development and human cardiovascular disease, D. melanogaster is of biologic interest because it has an open circulation. Open circulations are of evolutionary and physiologic interest. Given that open circulatory dynamics are not as well defined as those of closed circulation, and given a growing appreciation and understanding of the complexity and diversity of open circulations (see, for example, Ref. 23), Doppler OCT in D. melanogaster may have broad interest in biology.

Acknowledgments

This work was generously supported by the Frederick H. Lovejoy Fund, Children’s Hospital Boston (MAC) and by an American Medical Association Foundation Seed Grant (MAC). We additionally acknowledge funding support from NIH R01HL076398 and NIH R01CA103769 (development of the imaging system) and from the Department of Defense Air Force Office of Scientific Research, Medical Free Electron Laser Program FA9550-04-1-0079.

References

1. 

Y. Tao and R. A. Schulz, “Heart development in Drosophila,” Semin Cell Dev. Biol., 18 (1), 3 –15 (2007). https://doi.org/10.1016/j.semcdb.2006.12.001 1084-9521 Google Scholar

2. 

E. Bier and R. Bodmer, “Drosophila, an emerging model for cardiac disease,” Gene, 342 (1), 1 –11 (2004). https://doi.org/10.1016/j.gene.2004.07.018 0378-1119 Google Scholar

3. 

A. L. Parks, K. R. Cook, M. Belvin, N. A. Dompe, R. Fawcett, K. Huppert, L. R. Tan, C. G. Winter, K. P. Bogart, J. E. Deal, M. E. Deal-Herr, D. Grant, M. Marcinko, W. Y. Miyazaki, S. Robertson, K. J. Shaw, M. Tabios, V. Vysotskaia, L. Zhao, R. S. Andrade, K. A. Edgar, E. Howie, K. Killpack, B. Milash, A. Norton, D. Thao, K. Whittaker, M. A. Winner, L. Friedman, J. Margolis, M. A. Singer, C. Kopczynski, D. Curtis, T. C. Kaufman, G. D. Plowman, G. Duyk, and H. L. Francis-Lang, “Systematic generation of high-resolution deletion coverage of the Drosophila melanogaster genome,” Nat. Genet., 36 (3), 288 –292 (2004). https://doi.org/10.1038/ng1312 1061-4036 Google Scholar

4. 

B. Zeitouni, S. Senatore, D. Severac, C. Aknin, M. Semeriva, and L. Perrin, “Signalling pathways involved in adult heart formation revealed by gene expression profiling in Drosophila,” PLoS Genet, 3 (10), 1907 –1921 (2007). https://doi.org/10.1371/journal.pgen.0030174 Google Scholar

5. 

K. Ocorr, N. L. Reeves, R. J. Wessells, M. Fink, H. S. Chen, T. Akasaka, S. Yasuda, J. M. Metzger, W. Giles, J. W. Posakony, and R. Bodmer, “KCNQ potassium channel mutations cause cardiac arrhythmias in Drosophila that mimic the effects of aging,” Proc. Natl. Acad. Sci. U.S.A., 104 (10), 3943 –3948 (2007). https://doi.org/10.1073/pnas.0609278104 0027-8424 Google Scholar

6. 

M. J. Wolf, H. Amrein, J. A. Izatt, M. A. Choma, M. C. Reedy, and H. A. Rockman, “Drosophila as a model for the identification of genes causing adult human heart disease,” Proc. Natl. Acad. Sci. U.S.A., 103 (5), 1394 –1399 (2006). https://doi.org/10.1073/pnas.0507359103 0027-8424 Google Scholar

7. 

M. A. Choma, S. D. Izatt, R. J. Wessells, R. Bodmer, and J. A. Izatt, “In vivo imaging of the adult Drosophila melanogaster heart with real-time optical coherence tomography,” Circulation, 114 (2), E35 –E36 (2006). https://doi.org/10.1161/CIRCULATIONAHA.105.593541 0009-7322 Google Scholar

8. 

B. Monier, M. Astier, M. Semeriva, and L. Perrin, “Steroid-dependent modification of Hox function drives myocyte reprogramming in the Drosophila heart,” Development, 132 (23), 5283 –5293 (2005). https://doi.org/10.1242/dev.02091 0950-1991 Google Scholar

9. 

K. A. Ocorr, T. Crawley, G. Gibson, and R. Bodmer, “Genetic variation for cardiac dysfunction in Drosophila,” PLoS ONE, 2 (7), e601 (2007). https://doi.org/10.1371/journal.pone.0000601 1932-6203 Google Scholar

10. 

M. J. Allikian, G. Bhabha, P. Dospoy, A. Heydemann, P. Ryder, J. U. Earley, M. J. Wolf, H. A. Rockman, and E. M. McNally, “Reduced life span with heart and muscle dysfunction in Drosophila sarcoglycan mutants,” Hum. Mol. Genet., 16 (23), 2933 –2943 (2007). https://doi.org/10.1093/hmg/ddm254 0964-6906 Google Scholar

11. 

S. A. Boppart, G. J. Tearney, B. E. Bouma, J. F. Southern, M. E. Brezinski, and J. G. Fujimoto, “Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography,” Proc. Natl. Acad. Sci. U.S.A., 94 (9), 4256 –4261 (1997). https://doi.org/10.1073/pnas.94.9.4256 0027-8424 Google Scholar

12. 

S. Yazdanfar, M. D. Kulkarni, and J. A. Izatt, “High-resolution imaging of in vivo cardiac dynamics using color Doppler optical coherence tomography,” Opt. Express, 1 (13), 424 –431 (1997). https://doi.org/10.1364/OE.1.000424 1094-4087 Google Scholar

13. 

T. M. Yelbuz, M. A. Choma, L. Thrane, M. L. Kirby, and J. A. Izatt, “Optical coherence tomography—a new high-resolution imaging technology to study cardiac development in chick embryos,” Circulation, 106 (22), 2771 –2774 (2002). https://doi.org/10.1161/01.CIR.0000042672.51054.7B 0009-7322 Google Scholar

14. 

M. W. Jenkins, D. C. Adler, M. Gargesha, R. Huber, F. Rothenberg, J. Belding, M. Watanabe, D. L. Wilson, J. G. Fujimoto, and A. M. Rollins, “Ultrahigh-speed optical coherence tomography imaging and visualization of the embryonic avian heart using a buffered Fourier domain mode locked laser,” Opt. Express, 15 (10), 6251 –6267 (2007). https://doi.org/10.1364/OE.15.006251 1094-4087 Google Scholar

15. 

A. Mariampillai, B. A. Standish, N. R. Munce, C. Randall, G. Liu, J. Y. Jiang, A. E. Cable, I. A. Vitkin, and V. X. D. Yang, “Doppler optical cardiogram gated 2D color flow imaging at 1000fps and 4D in vivo visualization of embryonic heart at 45fps on a swept source OCT system,” Opt. Express, 15 (4), 1627 –1638 (2007). https://doi.org/10.1364/OE.15.001627 1094-4087 Google Scholar

16. 

M. W. Jenkins, F. Rothenberg, D. Roy, V. P. Nikolski, Z. Hu, M. Watanabe, D. L. Wilson, I. R. Efimov, and A. M. Rollins, “4D embryonic cardiography using gated optical coherence tomography,” Opt. Express, 14 (2), 736 –748 (2006). https://doi.org/10.1364/OPEX.14.000736 1094-4087 Google Scholar

17. 

M. W. Jenkins, P. Patel, H. Y. Deng, M. M. Montano, M. Watanabe, and A. M. Rollins, “Phenotyping transgenic embryonic murine hearts using optical coherence tomography,” Appl. Opt., 46 (10), 1776 –1781 (2007). https://doi.org/10.1364/AO.46.001776 0003-6935 Google Scholar

18. 

A. M. Davis, F. G. Rothenberg, N. Shepherd, and J. A. Izatt, “In vivo spectral domain optical coherence tomography volumetric imaging and spectral Doppler velocimetry of early stage embryonic chicken heart development,” J. Opt. Soc. Am. A, 25 (12), 3134 –3143 (2008). https://doi.org/10.1364/JOSAA.25.003134 0740-3232 Google Scholar

19. 

R. Yelin, D. Yelin, W.-Y. Oh, S. H. Yun, C. Boudoux, B. J. Vakoc, B. E. Bouma, and G. J. Tearney, “Multimodality optical imaging of embryonic heart microstructure,” J. Biomed. Opt., 12 (6), 064021 (2007). https://doi.org/10.1117/1.2822904 1083-3668 Google Scholar

20. 

J. H. Law and M. A. Wells, “Insects as biochemical models,” J. Biol. Chem., 264 (28), 16335 –16338 (1989). 0021-9258 Google Scholar

21. 

T. Burmester and T. Hankeln, “The respiratory proteins of insects,” J. Insect Physiol., 53 (4), 285 –294 (2007). https://doi.org/10.1016/j.jinsphys.2006.12.006 0022-1910 Google Scholar

22. 

D. Dulcis and R. B. Levine, “Innervation of the heart of the adult fruit fly, Drosophila melanogaster,” J. Comp. Neurol., 465 (4), 560 –578 (2003). https://doi.org/10.1002/cne.10869 0021-9967 Google Scholar

23. 

L. T. Wasserthal, “Drosophila flies combine periodic heartbeat reversal with a circulation in the anterior body mediated by a newly discovered anterior pair of ostial valves and ‘venous’ channels,” J. Exp. Biol., 210 (Pt 21), 3707 –3719 (2007). https://doi.org/10.1242/jeb.007864 0022-0949 Google Scholar

24. 

D. Dulcis and R. B. Levine, “Glutamatergic innervation of the heart initiates retrograde contractions in adult Drosophila melanogaster,” J. Neurosci., 25 (2), 271 –280 (2005). https://doi.org/10.1523/JNEUROSCI.2906-04.2005 0270-6474 Google Scholar

25. 

K. Isaaz, A. Thompson, G. Ethevenot, J. L. Cloez, B. Brembilla, and C. Pernot, “Doppler echocardiographic measurement of low-velocity motion of the left ventricular posterior wall,” Am. J. Cardiol., 64 (1), 66 –75 (1989). https://doi.org/10.1016/0002-9149(89)90655-3 0002-9149 Google Scholar

26. 

N. R. Van de Veire, J. De Sutter, J. J. Bax, and J. R. Roelandt, “Technological advances in tissue Doppler imaging echocardiography,” Heart (Br. Cardiac Soc.), 94 (8), 1065 –1074 (2008). Google Scholar

27. 

B. J. Vakoc, S. H. Yun, J. F. de Boer, G. J. Tearney, and B. E. Bouma, “Phase-resolved optical frequency domain imaging,” Opt. Express, 13 (14), 5483 –5493 (2005). https://doi.org/10.1364/OPEX.13.005483 1094-4087 Google Scholar

28. 

M. A. Choma, A. K. Ellerbee, C. Yang, T. L. Creazzo, and J. A. Izatt, “Spectral-domain phase microscopy,” Opt. Lett., 30 (10), 1162 –1164 (2005). https://doi.org/10.1364/OL.30.001162 0146-9592 Google Scholar

29. 

W. S. Rasband, ImageJ, (2009) Google Scholar

30. 

N. J. Curtis, J. M. Ringo, and H. B. Dowse, “Morphology of the pupal heart, adult heart, and associated tissues in the fruit fly, Drosophila melanogaster,” J. Morphol., 240 (3), 225 –235 (1999). https://doi.org/10.1002/(SICI)1097-4687(199906)240:3<225::AID-JMOR2>3.0.CO;2-V 0362-2525 Google Scholar

31. 

Y. H. Zhao, Z. P. Chen, C. Saxer, Q. M. Shen, S. H. Xiang, J. F. de Boer, and J. S. Nelson, “Doppler standard deviation imaging for clinical monitoring of in vivo human skin blood flow,” Opt. Lett., 25 (18), 1358 –1360 (2000). https://doi.org/10.1364/OL.25.001358 0146-9592 Google Scholar

32. 

M. A. Choma, A. K. Ellerbee, S. Yazdanfar, and J. A. Izatt, “Doppler flow imaging of cytoplasmic streaming using spectral domain phase microscopy,” J. Biomed. Opt., 11 (2), 024014 (2006). https://doi.org/10.1117/1.2193167 1083-3668 Google Scholar

33. 

J. M. Schmitt, “OCT elastography: imaging microscopic deformation and strain of tissue,” Opt. Express, 3 (6), 199 –211 (1998). https://doi.org/10.1364/OE.3.000199 1094-4087 Google Scholar
©(2010) Society of Photo-Optical Instrumentation Engineers (SPIE)
Michael A. Choma M.D., Melissa J. Suter, Benjamin J. Vakoc, Brett E. Bouma, and Gary J. Tearney "Heart wall velocimetry and exogenous contrast-based cardiac flow imaging in Drosophila melanogaster using Doppler optical coherence tomography," Journal of Biomedical Optics 15(5), 056020 (1 September 2010). https://doi.org/10.1117/1.3503418
Published: 1 September 2010
Lens.org Logo
CITATIONS
Cited by 25 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Heart

Doppler effect

Optical coherence tomography

Doppler tomography

Velocimetry

Particles

Video

Back to Top