18 January 2022 Sensitivity-enhanced optical sensor based on multilayer coated Fabry–Pérot interferometer
Tuo Chen, Hui-Hui Zhu, Chang Su, Zi-Wei Cao, Qiu-Shun Li, Mingyu Li
Author Affiliations +
Abstract

A high-sensitivity optical sensor based on a Fabry–Pérot interferometer (FPI) has been demonstrated. The cavity of the FPI is formed by two parallel half-reflective film-coated glass substrates with a distance of 1 mm and works as the sensing area. The interaction between the propagating wave and the analyte gives the sensing signal. High sensitivity of 1149  nm  /  RIU has been achieved for the wavelength interrogation. The Fabry–Pérot sensor can be made into a large array with multiple microfluidic channels to detect the different types of analytes. It has great potential in biochemical sensing.

© 2022 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2022/$28.00 © 2022 SPIE
Tuo Chen, Hui-Hui Zhu, Chang Su, Zi-Wei Cao, Qiu-Shun Li, and Mingyu Li "Sensitivity-enhanced optical sensor based on multilayer coated Fabry–Pérot interferometer," Optical Engineering 61(1), 017102 (18 January 2022). https://doi.org/10.1117/1.OE.61.1.017102
Received: 15 June 2021; Accepted: 27 December 2021; Published: 18 January 2022
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Glasses

Optical sensors

Interferometers

Multilayers

Waveguides

Optical engineering

RELATED CONTENT

Integrated optic device for biochemical sensing
Proceedings of SPIE (March 01 1991)
Integrated optic sensor with macro-flow cell
Proceedings of SPIE (March 02 1993)
Integrated optical difference interferometer
Proceedings of SPIE (February 13 1997)

Back to Top