We present the fabrication of high-quality graphitic micro-wires in diamond which are conductive in nature using pulsed Bessel beams. The electrodes are created in the bulk of 500 μm thick monocrystalline CVD and HPHT diamond samples perpendicular to the sample surface without sample translation or beam scanning. The role of various beam parameters such as pulse energy and pulse duration, different crystallographic orientations of the sample and two different writing modes of the laser namely burst mode and single-pulse mode in the conductivity of such electrodes are investigated. While the morphology of the electrodes is analysed using optical microscopy, the conductivity is measured experimentally using current-voltage characterisation. Furthermore, micro-Raman spectroscopy is implemented to investigate the graphitic content of electrodes fabricated. We have observed that higher pulse duration favours better conductivity while pulse energy has an optimum value for the same. As for the crystallographic orientations, we have found that it is possible to eradicate the potential barrier in the current-voltage curves completely even for graphitic wires fabricated at low pulse energy and in the fs pulse duration regime in a (110) oriented sample in contrast to the (100) oriented-crystal case where the barrier is generally observed. Finally, in case of wires fabricated with laser bursts with femtosecond sub-pulses, the higher number of sub-pulses, lower time delay between them and longer total burst duration favours better conductivity. Through various optimisation techniques, we report resistivity values as low as 0.01 Ω cm for the Bessel beam written electrodes in diamond.
In the last two decades quartz has become a relevant material for sensing technology since it has been used for realization of various devices, such as Quartz Crystal Microbalance (QCM) or Quartz-Tuning-Fork (QTF). Micromachining of quartz can be realized through various techniques, such as diamond cutting, lithography, wet and dry etching, ion beam etching and Ultra-Short-Pulsed-Laser (USPL) processing. At the state-of-the-art USPL has been efficiently applied to quartz micromachining, e.g., for drilling and stealth dicing. In this study, the influence of the incubation effect and the repetition rate on USPL ablation threshold of quartz was systematically investigated. The multi-pulse ablation threshold of quartz was evaluated using 200 fs laser pulses at a wavelength of 1030 nm, at three different repetition rates, i.e., 0.06, 6, 60 and 200 kHz. Results show a strong decrease in the multi-pulse ablation threshold with the number of pulses N, as a consequence of the effect of incubation during the fs-laser ablation. Conversely, the influence of the repetition rate on incubation is negligible in the investigated frequency range. A saturation of the threshold fluence value occurs at number of pulses N > 100 and this trend is well fitted by an exponential incubation model. Using such a model, the single-pulse ablation threshold value and the incubation coefficient for quartz have been estimated. This investigation represents a first step towards the micro- and nano-texturing of quartz crystal for tailoring its mechanical, electrical, and optical properties.
Development of new lab-on-a-chip (LoC) devices requires an optimization phase in which it could be necessary to continuously modify the architecture and geometry. However, this is only possible if easy, controllable fabrication methods and low-cost materials are available. For this reason, rapid prototyping approaches for the fabrication of polymeric LoC are on the rise, as they allow high degrees of precision and flexibility. Here, we describe the fabrication platform of polymeric microfluidic devices, from the design (CAD) to the proof-ofconcept application as LoC for biological applications. The fabrication procedure is mainly based on fs-laser micromachining techniques. The ability of femtosecond (fs)-laser pulses to produce localized modification of the materials, thereby avoiding either debris, recast layers or unsought thermal affected zones, without restriction of the substrate materials, makes this technology particularly suitable for microfluidic device fabrication. In our work, fs-laser has been also possibly combined with other techniques, without the need for the expensive masks and facilities required by the lithographic process. The LoC devices have been realized in polymethyl methacrylate (PMMA), a low cost and biocompatible material. The fs-based smart fabrication platform has been exploited in the fabrication of disposable LoC devices for particles manipulation. In particular, a serpentine microchannel able to distinguish cancer from non-cancer cells without labeling and a fully inertial sorting 3D device have been fabricated and tested.
We report on an experimental and theoretical investigation on the laser ablation of silicon with THz bursts of fs pulses. Craters were generated by varying the burst features, i.e., the number of pulses and the intra-burst repetition rate, and compared to those obtained in Normal Pulse Mode (NPM). A general reduction of the thermal load was observed using bursts, though with a lower ablation rate. In fact, shallower craters were obtained when increasing the number of pulses and reducing the intra-burst repetition rates at fixed processing time and burst energy. However, for bursts at 2 THz, some combinations of process parameters allowed a higher specific ablation rate compared to NPM. Simulations based on the numerical solution of the density-dependent two temperature model showed that bursts with more pulses or with lower intra-burst repetition rates lead to a lower final temperature, thus supporting the experimental findings. This is ascribed to changes of the reflectivity dependent on the number of pulses. Accordingly, different amounts of energy are transferred from the laser pulse to the sample, which also leads to changes in specific ablation rates. The origin of such a behavior was found to be the non-linear absorption processes, especially the two-photon absorption.
Utilization of parts made by combining dissimilar materials, such as different polymers, metals, or semiconductor to polymers, are nowadays highly demanded for the fabrication of electronic, electromechanical, medical micro-devices, and analytical systems (e.g., lab-on-chip). Techniques for joining such hybrid micro-devices, generally based on gluing or thermal processes, remain a challenging task presenting some drawbacks, such as deterioration and contamination of the substrates. Ultrashort laser welding is a non-contact and flexible technique to precisely weld similar and dissimilar materials. In this case, the only constrain is that the upper substrate is transparent to the laser wavelength. This technique has been demonstrated both for welding polymers and polymers to metallic substrates, but never for joining polymers to silicon. In this work, we report on direct femtosecond laser welding of Poly(methyl methacrylate) (PMMA) and silicon. The laser welding was performed in ambient air by focusing ultrashort laser pulses at high repetition rate at the interface between the two, being PMMA transparent to the laser wavelength. A mechanical homogenous pressure was applied on the sandwiched substrates during all the laser process. The Si-PMMA weld strength was evaluated as a function of the laser and processing parameters, e.g., repetition rate, scan speed, and the overlap between adjacent scan lines.
Many surfaces in nature, e.g. lotus leaf, exhibit superhydrophobicity. Some of the most attractive applications of these surfaces are based on their self-cleaning properties and anti-icing capability. Many strategies are used by researchers to replicate these natural phenomena on metallic substrates. Among them, short/ultrashort pulsed laser technologies can functionalize surfaces with micro/nano-textures enabling strong water-repellent properties and low adhesiveness, which represent a promising solution to anti-icing properties. In this work, several patterns of micro-structures were textured by femtosecond laser on metallic materials of aeronautic and aerospace interest. The wettability properties of the surfaces were investigated in terms of water contact angle (CA) under different ambient conditions. The reversibility of the sample superhydrophobicity after exposure to a highly humid environment was studied. Water-dripping tests were carried out at subzero temperature finding that, while the untreated samples were covered with ice, no frozen spot was observed on the superhydrophobic textured surfaces.
In this work, we report on a single-pass method for cutting 250-μm thick Z-cut quartz plates using 200 fs laser pulses at the wavelength of 1030 nm. In particular, we delve into the influence of the process parameters, i.e. laser repetition rate, scan speed and pulse energy, on the generation of a controlled stress-induced fracture which ultimately leads to the final cut. Processing above a certain threshold pulse energy caused significant damage, resulting in poor quality cuts. Whereas, a correct combination of these parameters led to a flat and almost defect-free cut edges, in a single pass.
In this work, we report on the fabrication of laser induced periodic surface structures (LIPSS) on stainless steel, using bursts of 200 fs sub-pulses at a wavelength of 1030 nm. A cascade of birefringent crystals was used to generate the bursts with tunable number of sub-pulses and intra-burst delays varying between 1.5 ps and 24 ps. Being such a delay shorter than the typical electron-lattice relaxation time in metals, the sub-pulses impinge on the sample surface when the material is still in a transient state after excitation from the first sub-pulse, thus allowing peculiar structures to be generated depending on the burst features. We obtained 1-D and 2-D periodic surface structures and investigated the influence of number of sub-pulses and polarization on their morphology. In particular, when bursts composed by all-aligned linearly polarized sub-pulses were used, 1-D LIPSS were obtained with different periodicity and depths depending on the number of sub-pulses. Bursts with crossed linear polarization or circular polarization sub-pulses produced 2-D LIPSS with morphology varying from triangular structures arranged in hexagonal lattice to pillar-like ordered or disordered structures depending on the bursts features. In most cases these structures exhibit a superhydrophobic behavior, as assessed by static contact angle measurements, which is achieved after a time of exposition to laboratory air. By XPS analysis we investigated the chemical variations occurring on the surfaces over this time.
Inertial microfluidic particles sorting represents a critical task in many areas of biology, biotechnology, and medicine, including the isolation from blood of rare target cell populations, like e.g. circulating tumor cells (CTCs) and circulating fetal cells (CFCs). Usually, cell sorter microfluidic devices are fabricated by PDMS soft lithography, which is the most widespread micromanufacturing platform enabling to cost-effectively produce Lab-on-a-Chip with resolution in the nanometer scale. However, this technology presents some drawbacks: (i) due to PDMS softness, especially for high-pressure flows, the microfluidic behavior may change along the devices, leading to ambiguous results; (ii) soft-lithography allows to pattern structures on just one side of the chip thus limiting the affordable geometries to enhance the throughput of target particles. In this work, we develop a PMMA continuous size-based inertial microfluidic sorter by femtosecond laser microfabrication (FLM). The device design includes contracting and expanding channels (microchambers) provided with siphoning outlets on the backside of the chip. Since FLM technology is in principle applicable to any type of polymer, we chose PMMA, which is a biocompatible and transparent thermoplastic polymer much stiffer than PDMS. FLM allows machining the microfluidic network on both sides of the chip, making it possible the parallelization of the sorting process. In addition, thanks to the FLM flexibility, we easily varied the chambers number and the collecting strategy (at different flow rates) in order to define a device layout maximizing the trapping efficiency and throughput.
We report on an experimental study of the incubation effect during irradiation of stainless steel targets with bursts of femtosecond laser pulses at 1030 nm wavelength and 100 kHz repetition rate. The bursts were generated by splitting the pristine 650-fs laser pulses using an array of birefringent crystals which provided time separations between sub-pulses in the range from 1.5 ps to 24 ps. We measured the threshold fluence in Burst Mode, finding that it strongly depends on the bursts features. The comparison with Normal Pulse Mode revealed that the existing models introduced to explain the incubation effect during irradiation with trains of undivided pulses has to be adapted to describe incubation during Burst Mode processing. In fact, those models assume that the threshold fluence has a unique value for each number of impinging pulses in NPM, while in case of BM we observed different values of threshold fluence for fixed amount of sub-pulses but different pulse splitting. Therefore, the incubation factor coefficient depends on the burst features. It was found that incubation effect is higher in BM than NPM and that it increases with the number of sub-pulses and for shorter time delays within the burst. Two-Temperature-Model simulations in case of single pulses and bursts of up to 4 sub-pulses were performed to understand the experimental results.
We present a cost-effective and highly-portable plastic prototype that can be interfaced with a cell phone to implement an optofluidic imaging cytometry platform. It is based on a PMMA microfluidic chip that fits inside an opto-mechanical platform fabricated by a 3D printer. The fluorescence excitation and imaging is performed using the LED and the CMOS from the cell phone increasing the compactness of the system. A custom developed application is used to analyze the images and provide a value of particle concentration.
Microfluidic optical stretchers are valuable optofluidic devices for studying single cell mechanical properties. These usually consist of a single microfluidic channel where cells, with dimensions ranging from 5 to 20 μm are trapped and manipulated through optical forces induced by two counter-propagating laser beams. Recently, monolithic optical stretchers have been directly fabricated in fused silica by femtosecond laser micromachining (FLM). Such a technology allows writing in a single step in the substrate volume both the microfluidic channel and the optical waveguides with a high degree of precision and flexibility. However, this method is very slow and cannot be applied to cheaper materials like polymers. Therefore, novel technological platforms are needed to boost the production of such devices on a mass scale.
In this work, we propose integration of FLM with micro-injection moulding (μIM) as a novel route towards the cost-effective and flexible manufacturing of polymeric Lab-on-a-Chip (LOC) devices. In particular, we have fabricated and assembled a polymethylmethacrylate (PMMA) microfluidic optical stretcher by exploiting firstly FLM to manufacture a metallic mould prototype with reconfigurable inserts. Afterwards, such mould was employed for the production, through μIM, of the two PMMA thin plates composing the device. The microchannel with reservoirs and lodgings for the optical fibers delivering the laser radiation for cell trapping were reproduced on one plate, while the other included access holes to the channel. The device was assembled by direct fs-laser welding, ensuring sealing of the channel and avoiding thermal deformation and/or contamination.
We report on an experimental investigation of ultrafast laser ablation of silicon with bursts of pulses. The pristine 1030nm-wavelength 200-fs pulses were split into bursts of up to 16 sub-pulses with time separation ranging from 0.5ps to 4080ps. The total ablation threshold fluence was measured depending on the burst features, finding that it strongly increases with the number of sub-pulses for longer sub-pulse delays, while a slowly increasing trend is observed for shorter separation time. The ablation depth per burst follows two different trends according to the time separation between the sub-pulses, as well as the total threshold fluence. For delays shorter than 4ps it decreases with the number of pulses, while for time separations longer than 510ps, deeper craters were achieved by increasing the number of subpulses in the burst, probably due to a change of the effective penetration depth.
Femtosecond-pulsed laser welding of transparent materials on a micrometer scale is a versatile tool for the fabrication and assembly of electronic, electromechanical, and especially biomedical micro-devices. In this paper, we report on microwelding of two transparent layers of polymethyl methacrylate (PMMA) with femtosecond laser pulses at 1030 nm in the MHz regime. We aim at exploiting localized heat accumulation to weld the two layers without any preprocessing of the sample and any intermediate absorbing media, by focusing fs-laser pulses at the interface.
The modifications produced by the focused laser beam into the bulk material have been firstly investigated depending on the laser process parameters aiming to produce continuous melting. Results have been evaluated based on heat accumulation models. Finally, fs-laser welding of PMMA samples have been successfully demonstrated and tested by leakage tests for application in direct laser assembly of microfluidic devices.
Surface micro-texturing has been widely theoretically and experimentally demonstrated to be beneficial to friction
reduction in sliding contacts under lubricated regimes. Several microscopic mechanisms have been assessed to concur to
this macroscopic effect. In particular, the micro-textures act as lubricant reservoirs, as well as traps for debris.
Furthermore, they may produce a local reduction of the shear stress coupled with a stable hydrodynamic pressure
between the lubricated sliding surfaces. All these mechanisms are strongly dependent both on the micro-texturing
geometry and on the operating conditions.
Among the various micro-machining techniques, laser ablation with ultrashort pulses is an emerging technology to
fabricate surface textures, thanks to the intrinsic property of laser light to be tightly focused and the high flexibility and
precision achievable. In addition, when using sub-ps pulses, the thermal damage on the workpiece is negligible and the
laser surface textures (LST) are not affected by burrs, cracks or resolidified melted droplets, detrimental to the frictional
properties.
In this work several LST geometries have been fabricated by fs-laser ablation of steel surfaces, varying the diameter,
depth and spacing of micro-dimples squared patterns. We compared their frictional performance with a reference nontextured
sample, on a range of sliding velocities from the mixed lubrication to the hydrodynamic regime. The measured
Stribeck curves data show that the depth and diameter of the microholes have a huge influence in determining the
amount of friction reduction at the interface. Different theoretical interpretations to explain the experimental findings are
also provided.
Surface hardening with discrete laser spot treatment is an interesting solution since the adoption of a single pulse allows the treatment of different surface geometries avoiding the effect of back tempering. The aim of this work is to find a suitable process window in which operate to get best results in terms of hardness, diameter and depth of the treated region. A single pulse out of a fiber laser source impinging on a bearing hypereutectoid steel was used using different power values, pulse energy and defocussing distances, in order to get the optimal process parameters. The dimensions of the hardened zone and its hardness were then acquired and related to the laser process parameters, to the prior microstructure of the steel (spheroidized and tempered after oil quenching) and to the roughness on the specimen before the laser treatment. Experimental results highlighted that both the surface condition (in terms of roughness) and the initial steel microstructure have a great influence on the achieved hardness values and on the dimension of the laser hardened layer. The pulse energy and power strongly affected the dimension of the hardened layer, too.
We demonstrated a sensing technique for in-line ablation rate detection using a quantum cascade laser (QCL) under external optical feedback. The design of the QCL-based diagnostic system allowed to monitor the voltage modulation at the laser terminals induced by fast dynamics in the ablation process. Real-time detection of the ablation front velocity as well as in-situ investigations of the surface temperature were provided. Experimental results on fast ablation rates per pulse correlate well with the theoretical prediction. The detection range was demonstrated to be limited only by the QCL-probe emission wavelength, which is scalable up to the THz spectral region.
The recent development of ultrafast laser ablation technology in precision micromachining has dramatically increased
the demand for reliable and real-time detection systems to characterize the material removal process. In particular, the
laser percussion drilling of metals is lacking of non-invasive techniques able to monitor into the depth the spatial- and
time-dependent evolution all through the ablation process. To understand the physical interaction between bulk material
and high-energy light beam, accurate in-situ measurements of process parameters such as the penetration depth and the
removal rate are crucial. We report on direct real time measurements of the ablation front displacement and the removal
rate during ultrafast laser percussion drilling of metals by implementing a contactless sensing technique based on optical
feedback interferometry. High aspect ratio micro-holes were drilled onto steel plates with different thermal properties
(AISI 1095 and AISI 301) and Aluminum samples using 120-ps/110-kHz pulses delivered by a microchip laser fiber
amplifier. Percussion drilling experiments have been performed by coaxially aligning the diode laser probe beam with
the ablating laser. The displacement of the penetration front was instantaneously measured during the process with a
resolution of 0.41 μm by analyzing the sawtooth-like induced modulation of the interferometric signal out of the detector
system.
In-process monitoring and feedback control are fundamental actions for stable and good quality laser welding process. In
particular, penetration depth is one of the most critical features to be monitored. In this research, overlap welding of
stainless steel is investigated to stably reproduce a fixed penetration depth using both CO2 and Nd:YAG lasers. Plasma
electron temperatures of Fe(I) and Cr(I) are evaluated as in process monitoring using the measurement of intensities of
emission lines with fast spectrometers. The sensor system is calibrated using a quantitative relationship between electron
temperature and penetration depth in different welding conditions. Finally closed loop control of the weld penetration
depth is implemented by acquiring the electron temperature value and by adjusting the laser power to maintain a pre-set
penetration depth. A PI controller is successfully used to stabilize the electron temperature around the set point
corresponding to the right penetration depth starting from a wrong value of any initial laser power different than the set
point. Optical inspection of the weld surface and macroscopic analyses of cross sections verify the results obtained with
the proposed closed-loop system based on a spectroscopic controller and confirms the reliability of our system.
Direct real-time measurements of the penetration depth during laser micromachining has been demonstrated by
developing a novel ablation sensor based on laser diode feedback interferometry. Percussion drilling experiments have
been performed by focusing a 120-ps pulsed fiber laser onto metallic targets with different thermal conductivity. In-situ
monitoring of the material removal rate was achieved by coaxially aligning the beam probe with the ablating laser. The
displacement of the ablation front was revealed with sub-micrometric resolution by analyzing the sawtooth-like induced
modulation of the interferometric signal out of the detector system.
We present an experimental study of the drilling of metal targets with ultrashort laser pulses with pulse durations from
800 fs to 19 ps at repetition rates up to 1 MHz, average powers up to 70 Watts, using an Ytterbium-doped fiber CPA
system. Particle shielding and heat accumulation have been found to influence the drilling efficiency at high repetition
rates. Particle shielding causes an increase in the number of pulses for breakthrough. It occurs at a few hundred kHz,
depending on the pulse energy and duration. The heat accumulation effect is noticed at higher repetition rates. Although
it overbalances the particle shielding thus making the drilling process faster, heat accumulation is responsible for the
formation of a large amount of molten material that limits the hole quality. The variations of the pulse duration reveal
that heat accumulation starts at higher repetition rates for shorter pulse lengths. This is in agreement with the observed
higher ablation efficiency with shorter pulse duration. Thus, the shorter pulses might be advantageous if highest
precision and processing speed is required.
We report the realization of an evanescently coupled laser-written type II array in χ-cut Lithium niobate. Certain
processing parameters allow evanescent fields to extend beyond the regions of damage, while still increasing the
index sufficiently to guide light. An array consisting of eleven coupled waveguides was fabricated. Coupling
was evaluated by observing discrete diffraction patterns of single waveguide excitations at various array sites.
Homogeneous coupling was verified within the array, while the outermost guides are slightly detuned due to
being formed by just one damage structure.
Aluminum alloys are interesting in many and many industrial applications, from the classical aircraft industry to rail and road vehicles manufacturing (High Speed Train, Car Structure and Body). Recently much more attention for Aluminum Alloys, 5000 and 6000 Series, has been carried out by Shipbuilding Industry, especially for using in the H.S.L.C. (High Speed Light Craft). Therefore the aim of this experimental work has been to study, develop and test a reproducible CO2 laser welding procedure and technique of four specific alloys, that is AA 5083, AA 5383, AA 5059 (Al-Mg Alloys), and AA 6082 (Al-Mg-Si Alloy). Different techniques, methodologies, covering gases, nozzles, focusing lenses and mirrors, welding speed range, laser power range (1000 and 2500 W) have been carefully experimented. The melted zones properties have been evaluated by cross sections, and some visual inspections by a NIKON LUCIA Imaging System correlating each experimental test, results and evaluations to the adopted process parameters and to the thermo-physical properties of the tested alloys.
In this work we present an innovative optical sensor for on- line and non-intrusive welding process monitoring. It is based on the spectroscopic analysis of the optical VIS emission of the welding plasma plume generated in the laser- metal interaction zone. Plasma electron temperature has been measured for different chemical species composing the plume. Temperature signal evolution has been recorded and analyzed during several CO2-laser welding processes, under variable operating conditions. We have developed a suitable software able to real time detect a wide range of weld defects like crater formation, lack of fusion, excessive penetration, seam oxidation. The same spectroscopic approach has been applied for electric arc welding process monitoring. We assembled our optical sensor in a torch for manual Gas Tungsten Arc Welding procedures and tested the prototype in a manufacturing industry production line. Even in this case we found a clear correlation between the signal behavior and the welded joint quality.
An optical monitoring system for the welding process has been developed; it is based on the study of the optical emission of the welding plasma plume, created during the welding of stainless steels and other iron-based materials. In the first approach a continuous wave CO2 laser of 2500-Watt maximum power, available at the INFM Research Unit labs in Bari University, has been used as welding source. A detailed spectroscopic study of the visible and UV welding plasma emission has been carried out; many transition lines corresponding to the elements composing the material to be welded have been found. By means of an appropriate selection of these lines and suitable algorithms, the electronic temperature of the plasma plume has been calculated and its evolution recorded as a function of several welding parameters. The behavior of the registered signal has resulted to be correlated to the welded joint quality. These findings have allowed to design and assemble a portable, non-intrusive and real-time welding quality optical sensor which has been successfully tested for laser welding of metals in different geometrical configurations; it has been capable of detecting a wide range of weld defects normally occurring during industrial laser metal-working. This sensor has also been tested in arc welding industrial processes (TIG) with promising results.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.