The Cherenkov Telescope Array (CTA) is the major ground-based gamma-ray observatory under construction. The CTA South observatory is foreseen to consist of Large-, Medium-, and Small-sized imaging atmospheric Cherenkov telescopes (IACTs). The innovative Schwarzschild-Couder Telescope (SCT) is a candidate IACT and a proposed major U.S. contribution for the Medium-sized, 10m aperture telescopes for CTA. The SCT is designed to simultaneously achieve 8 degrees field of view and high imaging resolution with unprecedented 11,328 pixels camera by implementing novel, aplanatic, segmented dual-mirror optics and compact silicon photomultiplier detectors. This presentation will provide an overview of the SCT program in the U.S. including the construction of a full-scale prototype instrument by an international consortium of scientists with the focus on the alignment of the segmented primary and secondary mirrors and the ongoing upgrade of the camera to full scale.
The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a dual-mirror optics design that reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors. The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68-deg field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application-specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera that will fully populate the focal plane is in progress. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04 deg. Here, we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status, and first light.
The Cherenkov Telescope Array (CTA) is the next-generation ground-based observatory for very-high-energy gamma rays. One candidate design for CTA's medium-sized telescopes consists of the Schwarzschild-Couder Telescope (SCT), featuring innovative dual-mirror optics. The SCT project has built and is currently operating a 9.7-m prototype SCT (pSCT) at the Fred Lawrence Whipple Observatory (FLWO); such optical design enables the use of a compact camera with state-of-the art silicon photomultiplier detectors. A partially-equipped camera has recently successfully detected the Crab Nebula with a statistical significance of 8.6 standard deviations. A funded upgrade of the pSCT focal plane sensors and electronics is currently ongoing, which will bring the total number of channels from 1600 to 11328 and the telescope field of view from about 2.7° to 8° . In this work, we will describe the technical and scientific performance of the pSCT.
The novel 9.7m Schwarzschild-Couder Telescope (SCT), utilizing aspheric dual-mirror optical system, has been constructed as a prototype medium size x-ray telescope for the Cherenkov Telescope Array (CTA) observatory. The prototype SCT (pSCT) is designed to achieve simultaneously the wide (≥ 8°) field of view and the superior imaging resolution (0.067 per pixel) to significantly improve scientific capabilities of the observatory in conducting the sky surveys, the follow-up observations of multi-messenger transients with poorly known initial localization and the morphology studies of x-ray sources with angular extent. In this submission, we describe the hardware and software implementations of the telescope optical system as well as the methods specifically developed to align its complex optical system, in which both primary and secondary mirrors are segmented. The pSCT has detected Crab Nebula in June 2020 during ongoing commissioning, which was delayed due to worldwide pandemic and is not yet completed. Verification of pSCT performance is continuing and further improvement of optical alignment is anticipated.
For the first time in the history of ground-based y-ray astronomy, the on-axis performance of the dual mirror, aspheric, aplanatic Schwarzschild-Couder optical system has been demonstrated in a 9:7-m aperture imaging atmospheric Cherenkov telescope. The novel design of the prototype Schwarzschild-Couder Telescope (pSCT) is motivated by the need of the next-generation Cherenkov Telescope Array (CTA) observatory to have the ability to perform wide (≥8°) field-of-view observations simultaneously with superior imaging of atmospheric cascades (resolution of 0:067 per pixel or better). The pSCT design, if implemented in the CTA installation, has the potential to improve significantly both the x-ray angular resolution and the off-axis sensitivity of the observatory, reaching nearly the theoretical limit of the technique and thereby making a major impact on the CTA observatory sky survey programs, follow-up observations of multi-messenger transients with poorly known initial localization, as well as on the spatially resolved spectroscopic studies of extended x-ray sources. This contribution reports on the initial alignment procedures and point-spread-function results for the challenging segmented aspheric primary and secondary mirrors of the pSCT.
The first prototype of the Schwarzschild Couder Medium Size Telescope (pSCT) proposed for the CTA observatory has been installed in 2018 at the Fred Lawrence Whipple Observatory. The pSCT camera is composed of 25 modules with 64 channels each, covering only a small portion of the full focal plane of the telescope. The Italian Institute of Nuclear Physics (INFN) has developed and characterized in collaboration with Fondazione Bruno Kessler (FBK) a new generation of Silicon Photomultipliers (SiPMs) sensitive to the Near Ultraviolet wavelengths, based on the High Density technology (NUV-HD devices). The latest generation of 6×6 mm2 SiPMs (called NUV-HD3) have been used to equip a subsection of 9 out of 25 modules of the pSCT camera. An upgrade of this camera is foreseen between 2019 and 2020 using the same sensors, aiming to equip the full focal plane with 177 modules, for a total of more than 11000 pixels. We will present a full characterization of the performance of these devices, highlighting why they are suitable for Cherenkov light detection. An overview on the overall behavior of the installed sensors will be also given, providing information on the uniformity of the sensors and of the performance of the camera.
The Italian Institute of Nuclear Physics is currently involved in the development of a prototype for a camera based on Silicon Photomultipliers (SiPMs) for the Cherenkov Telescope Array (CTA), a new generation of telescopes for ground{based gamma{ray astronomy. In recent years, SiPMs have proven to be highly suitable devices for applications where high sensitivity to low{intensity light and fast responses are required. Among their many advantages are their low operational voltage when compared with classical photomultiplier tubes, mechanical robustness, and increased photo{detection efficiency (PDE). Moreover, due to the possibility of operating them during bright moonlight, SiPMs can therefore considerably increase telescope duty cycle.
Here we present a full characterization of a particular type of SiPM produced in Italy by the Fondazione Bruno Kessler, which is suitable for Cherenkov light detection in the Near-Ultraviolet (NUV). This device is a High{Density (HD) NUV SiPM, based on a micro cell of 40 μm × 40 μm and with an area of 6×6 mm2, providing low levels of dark noise and high PDE peaking in the NUV band. NUV-HD SiPMs will be arranged in a matrix of 8×8 single units to become part of the focal plane of the Schwarzschild-Couder Telescope prototype for CTA. An update on recent tests of the front-end electronics based on signal sampling with the TARGET-7 chip will be given as well.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.