Wide Field Optical Spectrograph (WFOS) is the first light instrument of Thirty Meter Telescope (TMT), which will be one of the wide field spectrographs for optical spectroscopy and can probe the faintest limits. In order to reach the faintest limits provided by the aperture of TMT, WFOS is designed to have multi-object slit-based spectrograph. WFOS can observe about ~60 objects in a given exposure and cover the full wavelength range in low resolution (R~1500) observing mode. Slitless spectroscopy has been popular in space based instruments, however it is not pursued in ground based observatories due to the background contamination. Considering large plate scale of TMT and oversampling of seeing disk we will be able to extract the individual spectra from WFOS slitless observing mode. Here we present the feasibility of slitless mode of TMT-WFOS and the sensitivity limit for various field densities focusing on MilkyWay satellite galaxies. We study the background contamination due to the bright targets and the density distribution of the satellite galaxy fields.
SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) is the next-generation, diffraction-limited, thermal infrared, fully cryogenic, coronagraphic exoplanet spectrograph and imager for W.M. Keck Observatory. SCALES is fed by the Keck II Adaptive Optics bench. Both modes use common fore-optics to simplify the optical design and have individual detectors, which are JWST flight spares. The imager mode operates from 1 to 5 microns with selectable narrow- and broadband filters over a field of view 12.3 arcseconds on a side, and the integral field spectrograph mode operates from 2 to 5 microns with both low and mid spectral resolutions (R∼ 100 to R∼ 7500) over a field of view 2.15 arcseconds on a side. The diamond-turned aluminum optics, most of which are already delivered, with the rest being fabricated, provide low distortion, low wavefront error, and high throughput for all modes. The slicing unit, located behind the lenslet array, allows SCALES to reach heretofore unheard-of spatially-resolved spectral resolution for exoplanet and disc observations from the ground with a coronagraphic integral field spectrograph. The SCALES consortium includes UC Observatories, CalTech, W.M. Keck Observatory, the Indian Institute of Astrophysics, and the University of Durham, with over 40 science team members. We report on the overall design and project status during its ongoing fabrication phase, which started in early 2023.
We present a conceptual design for a fiber positioning system for multi-object high-resolution spectroscopy, designed to be compatible with the upcoming large telescopes with a wide field of view. The design incorporates multiple Atmospheric Dispersion Correctors (ADCs) and tip-tilt mirrors that receive non-telecentric input from individual targets and direct it to the ADCs. Here, we introduce a mechanical design for the fiber positioner that accommodates the optics and operates in a curved focal plane with a Radius of Curvature (R) of 3m. This mechanical design provides four degrees of freedom to access the focal volume, enhancing targeting efficiency. The proposed design and an efficient target allocation algorithm ensure a targeting efficiency of approximately 80-100% for a primary observation session. We also present a methodology for target assignment, positioning, and quantification based on sequential and Monte Carlo (MC) algorithms. This method has been tested on realistic fields with varying target densities to validate its performance.
Highly multiplexed spectroscopic surveys have changed the astronomy landscape in recent years. However, these surveys are limited to low and medium spectral resolution. High spectral resolution spectroscopy is often photon starved and will benefit from a large telescope aperture. Multiplexed high-resolution surveys require a wide field of view and a large aperture for a suitable large number of bright targets. This requirement introduces several practical difficulties, especially for large telescopes, such as the future ELTs. Some of the challenges are the need for a wide field atmospheric dispersion corrector and to deal with the curved non-telecentric focal plane. Here we present a concept of Multi-Object Spectroscopy (MOS) mode for TMT High-Resolution Optical Spectrograph (HROS), where we have designed an atmospheric dispersion corrector for individual objects that fit inside a fiber positioner. We present the ZEMAX design and the performance of the atmospheric dispersion corrector for all elevations accessible by TMT.
We present the design of SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) a new 2-5 micron coronagraphic integral field spectrograph under construction for Keck Observatory. SCALES enables low-resolution (R∼50) spectroscopy, as well as medium-resolution (R∼4,000) spectroscopy with the goal of discovering and characterizing cold exoplanets that are brightest in the thermal infrared. Additionally, SCALES has a 12x12” field-of-view imager that will be used for general adaptive optics science at Keck. We present SCALES’s specifications, its science case, its overall design, and simulations of its expected performance. Additionally, we present progress on procuring, fabricating and testing long lead-time components.
We present the current design of WFOS, a wide-field UV/optical (0.31-1.0 µm) imaging spectrograph planned for first-light on the TMT International Observatory 30 m telescope. WFOS is optimized for high sensitivity across the entire optical waveband for low-to-moderate resolution (R ∼ 1500-5000) long-slit and multi-slit spectroscopy of very faint targets over a contiguous field of view of 8′ .3×3 ′ .0 at the f/15 Nasmyth focus of TMT. A key design goal for WFOS is stability and repeatability in all observing modes, made possible by its gravity-invariant opto-mechanical structure, with a vertical rotation axis and all reconfigurable components moving only in planes defined by tiered optical benches parallel to the Nasmyth platform. WFOS’s optics include a linear ADC correcting a 9′ diameter field, including both the science FoV and 4 patrolling acquisition, guiding, and wavefront sensing camera systems; a novel 2-mirror reflective collimator allowing the science FoV to be centered on the telescope optical axis; a dichroic beamsplitter dividing the collimated beam into 2 wavelength-optimized spectrometer channels (blue: 0.31-0.56 µm; red: 0.54-1.04 µm); selectable transmissive dispersers (VPH and/or VBG) with remotely configurable grating tilt (angle of incidence) and camera articulation that enable optimization of diffraction efficiency and wavelength coverage in each channel; all-refractive, wavelength-optimized f/2 spectrograph cameras, and UV/blue and red-optimized detector systems. The predicted instrumental through put of WFOS for spectroscopy averages > 56% over the full 0.31-1 µm range, from the ADC to the detector. When combined with the 30 m TMT aperture, WFOS will realize a factor of ∼20 gain in sensitivity compared to the current state of the art on 8-10 m-class telescopes.
The Wide Field Optical Spectrograph (WFOS) is one of the first-light instruments of Thirty Meter Telescope. It is a medium resolution, multi object, wide field optical spectrograph. Since 2005 the conceptual design of the instrument has focused on a slit-mask based, grating exchange design that will be mounted at the Nasmyth focus of TMT. Based on the experience with ESI, MOSFIRE and DEIMOS for Keck we know flexure related image motion will be a major problem with such a spectrograph and a compensation system is required to mitigate these effects.
We have developed a flexure Compensation and Simulation (FCS) tool for TMT-WFOS that provides an interface to accurately simulate the effects of instrument flexure at the WFOS detector plane (e.g image shifts) using perturbation of key optical elements and also derive corrective motions to compensate the image shifts caused by instrument flexure. We are currently using the tool to do mote-carlo simulations to validate the optical design of a slit-mask concept we call Xchange-WFOS, and to optimize the flexure compensation strategy. We intend to use the tool later in the design process to predict the actual flexure by replacing the randomized inputs with the signed displacement and rotations of each element predicted by global FEA model on the instrument..
TMT’s wide field optical spectrograph is a multi-object, first-light instrument with broad continuous wavelength coverage (0.310 – 1.0 m) at a moderate spectral resolution of R = 5000. The international WFOS design team has recently completed the downselect of two design approaches: a slicer-based monolithic architecture and a fiber-based modular concept. We present here the end-to-end conceptual design for the fiber-based optical spectrograph. Included are the front-end focal reduction optics for coupling light into the fibers, the spectrograph collimator and camera optics, and the dispersive architecture for each color channel. The highly multiplexed fiber-WFOS presents a unique design challenge in keeping costs for the modular spectrographs low while maintaining performance gains afforded by the TMT, and in particular the TMT plus ground-layer adaptive optics (GLAO). A full performance analysis including predicted spectral resolution and throughput is presented for the design.
The Wide Field Optical Spectrometer (WFOS) is a seeing limited, multi-object spectrograph and first light instrument for the Thirty Meter Telescope (TMT) scheduled for first observations in 2027. The spectrograph will deliver a minimum resolution of R~5,000 over a simultaneous wavelength range of 310 nm to 1,000 nm with a multiplexing goal of between 20 and 700 targets. The WFOS team consisting of partners in China, India, Japan, and the United States has completed a trade study of two competing concepts intended to meet the design requirements derived from the WFOS detailed science case. The first of these design concepts is a traditional slit mask instrument capable of delivering R~1,000 for up to 100 simultaneous targets using 1 x 7 arc second slits, and a novel focal plane slicing method for R~5,000 on up to 20 simultaneous targets can be achieved by reformatting the 1 arc-second wide slits into three 0.3 arc-second slits projected next to each other in the spatial direction. The second concept under consideration is a highly multiplexed fiber based system utilizing a robotic fiber positioning system at the focal plane containing 700 individual collectors, and a cluster of up to 12 replicated spectrographs with a minimum resolution of R~5,000 over the full pass band. Each collecting element will contain a bundle of 19 fibers coupled to micro-lens arrays that allow for contiguous coverage of targets and adaptation of the f/15 telescope beam to f/3.2 for feeding the fiber system. This report describes the baseline WFOS design, provides an overview of the two trade study concepts, and the process used to down-select between the two options. Also included is a risk assessment regarding the known technical challenges in the selected design concept.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.