Understanding and reducing in-orbit instrumental backgrounds are essential to achieving high sensitivity in hard x-ray astronomical observations. The observational data of the Hard X-ray Imager (HXI) onboard the Hitomi satellite provide useful information on the background components due to its multilayer configuration with different atomic numbers: the HXI consists of a stack of four layers of Si (Z = 14) detectors and one layer of cadmium telluride (CdTe) (Z = 48, 52) detector surrounded by well-type Bi4Ge3O12 active shields. Based on the observational data, the backgrounds of the top Si layer, the three underlying Si layers, and the CdTe layer are inferred to be dominated by different components, namely, low-energy electrons, albedo neutrons, and proton-induced radioactivation, respectively. Monte Carlo simulations of the in-orbit background of the HXI reproduce the observed background spectrum of each layer well, thereby quantitatively verifying the above hypothesis. In addition, we suggest the inclusion of an electron shield to reduce the background.
Hitomi (ASTRO-H) was the sixth Japanese x-ray satellite that carried instruments with exquisite energy resolution of <7 eV and broad energy coverage of 0.3 to 600 keV. The Soft Gamma-ray Detector (SGD) was the Hitomi instrument that observed the highest energy band (60 to 600 keV). The SGD design achieves a low background level by combining active shields and Compton cameras where Compton kinematics is utilized to reject backgrounds coming from outside of the field of view. A compact and highly efficient Compton camera is realized using a combination of silicon and cadmium telluride semiconductor sensors with a good energy resolution. Compton kinematics also carries information for gamma-ray polarization, making the SGD an excellent polarimeter. Following several years of development, the satellite was successfully launched on February 17, 2016. After proper functionality of the SGD components were verified, the nominal observation mode was initiated on March 24, 2016. The SGD observed the Crab Nebula for approximately two hours before the spacecraft ceased to function on March 26, 2016. We present concepts of the SGD design followed by detailed description of the instrument and its performance measured on ground and in orbit.
The hard x-ray imaging spectroscopy system of “Hitomi” x-ray observatory is composed of two sets of hard x-ray imagers (HXI) coupled with hard x-ray telescopes (HXT). With a 12-m focal length, the system provides fine (1 ′ . 7 half-power diameter) imaging spectroscopy covering about 5 to 80 keV. The HXI sensor consists of a camera, which is composed of four layers of Si and one layer of CdTe semiconductor imagers, and an active shield composed of nine Bi4Ge3O12 scintillators to provide low background. The two HXIs started observation on March 8 and 14, 2016 and were operational until 26 March. Using a Crab observation, 5 to 80 keV energy coverage and good detection efficiency were confirmed. The detector background level of 1 to 3 × 10 − 4 counts s − 1 keV − 1 cm − 2 (in detector geometrical area) at 5 to 80 keV was achieved, by cutting the high-background time-intervals, adopting sophisticated energy-dependent imager layer selection, and baffling of the cosmic x-ray background and active-shielding. This level is among the lowest of detectors working in this energy band. By comparing the effective area and the background, it was shown that the HXI had a sensitivity that is same to that of NuSTAR for point sources and 3 to 4 times better for largely extended diffuse sources.
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging spectrometer covering hard x-ray energies of 5 to 80 keV. Combined with the Hard X-ray Telescope, it enables imaging spectroscopy with an angular resolution of 1′.7 half-power diameter, in a field of view of 9′ × 9′. The main imager is composed of four layers of Si detectors and one layer of CdTe detector, stacked to cover a wide energy band up to 80 keV, surrounded by an active shield made of Bi4Ge3O12 scintillator to reduce the background. The HXI started observations 12 days before the Hitomi loss and successfully obtained data from G21.5–0.9, Crab, and blank sky. Utilizing these data, we calibrate the detector response and study properties of in-orbit background. The observed Crab spectra agree well with a powerlaw model convolved with the detector response, within 5% accuracy. We find that albedo electrons in specified orbit strongly affect the background of the Si top layer and establish a screening method to reduce it. The background level over the full field of view after all the processing and screening is as low as the preflight requirement of 1 − 3 × 10−4 counts s−1 cm−2 keV−1.
The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E > 2 keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month.
High-quality CdTe semiconductor detectors with both fine position resolution and high energy resolution hold great promise to improve measurement in various hard X-ray and gamma-ray imaging fields. ISAS/JAXA has been developing CdTe imaging detectors to meet scientific demands in latest celestial observation and severe environmental limitation (power consumption, vibration, radiation) in space for over 15 years.
The energy resolution of imaging detectors with a CdTe Schottky diode of In/CdTe/Pt or Al/CdTe/Pt contact is a highlight of our development. We can extremely reduce a leakage current of devises, meaning it allows us to supply higher bias voltage to collect charges. The 3.2cm-wide and 0.75mm-thick CdTe double-sided strip detector with a strip pitch of 250 µm has been successfully established and was mounted in the latest Japanese X-ray satellite. The energy resolution measured in the test on ground was 2.1 keV (FWHM) at 59.5 keV. The detector with much finer resolution of 60 µm is ready, and it was actually used in the FOXSI rocket mission to observe hard X-ray from the sun.
In this talk, we will focus on our research activities to apply space sensor technologies to such various imaging fields as medical imaging. Recent development of CdTe detectors, imaging module with pinhole and coded-mask collimators, and experimental study of response to hard X-rays and gamma-rays are presented. The talk also includes research of the Compton camera which has a configuration of accumulated Si and CdTe imaging detectors.
We studied a surface effect of Double-sided Si Strip Detectors (DSSDs) in order to apply it for imaging spectroscopy of X-ray photons down to 5 keV for the first time. The Japanese cosmic X-ray satellite Hitomi, launched in February 2016, is equipped with the Hard X-ray Imager (HXI), which employs the DSSDs in 5-80 keV. In such a low energy band, the surface effect is non-negligible. When interstrip regions of p-side are irradiated, the DSSD sometimes show signals with negative pulse heights, presumably caused by positive surface charges between Si and SiO2 layers.1{5 The effect modifies the X-ray response of the HXI towards its low-energy end, below ~ 10 keV. By irradiating the DSSD with uncollimated mono-energetic X-rays of different energies, we measured the fraction of the negative events to be 2% at 26.4 keV and 30% at 6.0 keV. Using an 8 keV colli- mated X-ray beam, we directly verified that the negative events originated from the interstrip gaps on the p-side where the SiO2 layers exist. The measured energy- and position- dependences can be modeled by assuming that the negative events are produced in approximately 25 μm deep and 120 μm wide interstrip regions. When the bias voltage are halved (from 350 V to 180 V), fraction of the negative events increased by a factor of ~ 1:7, qualitatively consistent with this picture.
We have developed a compact hard X-ray imaging system composed of a cadmium telluride double-sided strip detector (CdTe-DSD) and a coded mask. We investigate the imaging performance using two different coded masks with different sizes and patterns. In our system, a CdTe-DSD of pitch 250μm is used in conjunction with a coded mask is placed 70-100 mm above the detector to form a compact imaging system. We obtained an angular resolution of up to 11.8 arc min, as measured from gamma-ray lines of point-like radioactive isotope sources. This is consistent with that expected from the geometry. The energy resolution is 1.7 keV (FWHM) at 60 keV and the energy range of imaging is from 5 keV to 122 keV. These results agree very well with Monte Carlo simulations of the detector.
Hitomi X-ray observatory launched in 17 February 2016 had a hard X-ray imaging spectroscopy system made of two hard X-ray imagers (HXIs) coupled with two hard X-ray telescopes (HXTs). With 12 m focal length, they provide fine (2' half-power diameter; HPD) imaging spectroscopy at 5 to 80 keV. The HXI main imagers are made of 4 layers of Si and a CdTe semiconductor double-sided strip detectors, stacked to enhance detection efficiency as well as to enable photon interaction-depth sensing. Active shield made of 9 BGO scintillators surrounds the imager to provide with low background. Following the deployment of the Extensible Optical Bench (EOB) on 28 February, the HXI was gradually turned on. Two imagers successfully started observation on 14 March, and was operational till the incident lead to Hitomo loss, on 26 March. All detector channels, 1280 ch of imager and 11 channel of active shields and others each, worked well and showed performance consistent with those seen on ground. From the first light observation of G21.5-0.9 and the following Crab observations, 5-80 keV energy coverage and good detection efficiency were confirmed. With blank sky observations, we checked our background level. In some geomagnetic region, strong background continuum, presumably caused by trapped electron with energy ~100 keV, is seen. But by cutting the high-background time-intervals, the background became significantly lower, typically with 1-3 x 10-4 counts s-1 keV-1 cm-2 (here cm2 is shown with detector geometrical area). Above 30 keV, line and continuum emission originating from activation of CdTe was significantly seen, though the level of 1-4 x 10-4 counts s-1 keV-1 cm-2 is still comparable to those seen in NuSTAR. By comparing the effective area and background rate, preliminary analysis shows that the HXI had a statistical sensitivity similar to NuSTAR for point sources, and more than twice better for largely extended sources.
The Hitomi (ASTRO-H) mission is the sixth Japanese X-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E > 2 keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. After a successful launch on 2016 February 17, the spacecraft lost its function on 2016 March 26, but the commissioning phase for about a month provided valuable information on the on-board instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month.
The Soft Gamma-ray Detector (SGD) is one of science instruments onboard ASTRO-H (Hitomi) and features a wide energy band of 60{600 keV with low backgrounds. SGD is an instrument with a novel concept of "Narrow field-of-view" Compton camera where Compton kinematics is utilized to reject backgrounds which are inconsistent with the field-of-view defined by the active shield. After several years of developments, the flight hardware was fabricated and subjected to subsystem tests and satellite system tests. After a successful ASTRO-H (Hitomi) launch on February 17, 2016 and a critical phase operation of satellite and SGD in-orbit commissioning, the SGD operation was moved to the nominal observation mode on March 24, 2016. The Compton cameras and BGO-APD shields of SGD worked properly as designed. On March 25, 2016, the Crab nebula observation was performed, and, the observation data was successfully obtained.
The 6th Japanese X-ray satellite, ASTRO-H, is scheduled for launch in 2015. The hard X-ray focusing imaging system will observe astronomical objects with the sensitivity for detecting point sources with a brightness of 1/100,000 times fainter than the Crab nebula at > 10 keV. The Hard X-ray Imager (HXI) is a focal plane detector 12 m below the hard X-ray telescope (HXT) covering the energy range from 5 to 80 keV. The HXI is composed of a stacked Si/CdTe semiconductor detector module and surrounding BGO scintillators. The latter work as active shields for efficient reduction of background events caused by cosmic-ray particles, cosmic X-ray background, and in-orbit radiation activation. In this paper, we describe the detector system, and present current status of flight model development, and performance of HXI using an engineering model of HXI.
KEYWORDS: Signal processing, Sensors, Avalanche photodetectors, Logic, Cameras, Analog electronics, Signal detection, Digital filtering, Field programmable gate arrays, Gamma radiation
The hard X-ray imager (HXI) and soft gamma-ray detector (SGD) onboard Astro-H observe astronomical objects with high sensitivity in the hard X-ray (5−80 keV) and soft gamma-ray (40−600 keV) energy bands. To achieve this high sensitivity, background rejection is essential, and these detectors are surrounded by large and thick bismuth germinate scintillators as an active shield. We have developed adequate trigger logic for both the HXI and SGD to process signals from main detector and BGO shield simultaneously and then we optimized the trigger delay and width, with consideration of the trigger latch efficiency. The shield detector system performs well, even after it is assembled as the HXI sensor. The energy threshold maintains the same level as that observed during the prototype development phase, and the experimental room background level of the main detector is successfully reduced by our optimized trigger timing.
The Hard X-ray Imager and the Soft Gamma-ray Detector, onboard the 6th Japanese X-ray satellite ASTRO-H, aim at unprecedentedly-sensitive observations in the 5–80 keV and 40–600 keV bands, respectively. Because their main sensors are composed of a number of semi-conductor devices, which need to be operated in a temperature of –20 to –15◦C, heat generated in the sensors must be efficiently transported outwards by thermal conduction. For this purpose, we performed thermal design, with the following three steps. First, we additionally included thermally-conductive parts, copper poles and graphite sheets. Second, constructing a thermal mathematical model of the sensors, we estimated temperature distributions in thermal equilibria. Since the model had rather large uncertainties in contact thermal conductions, an accurate thermal dummy was constructed as our final step. Vacuum measurement with the dummy successfully reduced the conductance uncertainties. With these steps, we confirmed that our thermal design of the main sensors satisfies the temperature requirement.
The Soft Gamma-ray Detector (SGD) is one of observational instruments onboard the ASTRO-H, and will provide 10 times better sensitivity in 60{600 keV than the past and current observatories. The SGD utilizes similar technologies to the Hard X-ray Imager (HXI) onboard the ASTRO-H. The SGD achieves low background by constraining gamma-ray events within a narrow field-of-view by Compton kinematics, in addition to the BGO active shield. In this paper, we will present the results of various tests using engineering models and also report the flight model production and evaluations.
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. The simultaneous broad band pass, coupled with the high spectral resolution of ΔE ≤ 7 eV of the micro-calorimeter, will enable a wide variety of important science themes to be pursued. ASTRO-H is expected to provide breakthrough results in scientific areas as diverse as the large-scale structure of the Universe and its evolution, the behavior of matter in the gravitational strong field regime, the physical conditions in sites of cosmic-ray acceleration, and the distribution of dark matter in galaxy clusters at different redshifts.
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated
by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the highenergy
universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV.
These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3–12 keV with
high spectral resolution of ΔE ≦ 7 eV, enabled by a micro-calorimeter array located in the focal plane of
thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5–80 keV, located in the focal plane of
multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4–12 keV,
with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera
type soft gamma-ray detector, sensitive in the 40–600 keV band. The simultaneous broad bandpass, coupled
with high spectral resolution, will enable the pursuit of a wide variety of important science themes.
The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the
ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm × 3.2
cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of -20°C and with an
applied bias voltage of 250 V. By using two-strip events as well as one-strip events for the event reconstruction,
a good energy resolution of 2.0 keV at 59.5 keV and a sub-strip spatial resolution was achieved. The hard
X-ray and gamma-ray response of CdTe-DSDs is complex due to the properties of CdTe and the small pixel
effect. Therefore, one of the issues to investigate is the response of the CdTe-DSD. In order to investigate the
spatial dependence of the detector response, we performed fine beam scan experiments at SPring-8, a synchrotron
radiation facility. From these experiments, the depth structure of the electric field was determined as well as
properties of carriers in the detector and successfully reproduced the experimental data with simulated spectra.
ASTRO-H is the next generation JAXA X-ray satellite, intended to carry instruments with broad energy coverage and exquisite energy resolution. The Soft Gamma-ray Detector (SGD) is one of ASTRO-H instruments and will feature wide energy band (60–600 keV) at a background level 10 times better than the current instruments on orbit. The SGD is complimentary to ASTRO-H’s Hard X-ray Imager covering the energy range of 5–80 keV. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield where Compton kinematics is utilized to reject backgrounds. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and CdTe (cadmium telluride) sensors. Good energy resolution is afforded by semiconductor sensors, and it results in good background rejection capability due to better constraints on Compton kinematics. Utilization of Compton kinematics also makes the SGD sensitive to the gamma-ray polarization, opening up a new window to study properties of gamma-ray emission processes. In this paper, we will present the detailed design of the SGD and the results of the final prototype developments and evaluations. Moreover, we will also present expected performance based on the measurements with prototypes.
The Hard X-ray Imager (HXI) is one of the four detectors on board the ASTRO-H mission (6th Japanese X-ray satellite), which is scheduled to be launched in 2014. Using the hybrid structure composed of double-sided silicon strip detectors and a cadmium telluride double-sided strip detector, both with a high spatial resolution of 250 μm. Combined with the hard X-ray telescope (HXT), it consists a hard X-ray imaging spectroscopic instrument covering the energy range from 5 to 80 keV with an effective area of <300 cm2 in total at 30 keV. An energy resolution of 1–2 keV (FWHM) and lower threshold of 5 keV are both achieved with using a low noise front-end ASICs. In addition, the thick BGO active shields surrounding the main detector package is a heritage of the successful performance of the Hard X-ray Detector on board the Suzaku satellite. This feature enables the instrument to achieve an extremely good reduction of background caused by cosmic-ray particles, cosmic X-ray background, and in-orbit radiation activation. In this paper, we present the detector concept, design, latest results of the detector development, and the current status of the hardware.
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated
by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the
high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate angular
resolution. ASTRO-H covers very wide energy range from 0.3 keV to 600 keV. ASTRO-H allows a combination
of wide band X-ray spectroscopy (5-80 keV) provided by multilayer coating, focusing hard X-ray
mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-12 keV)
provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD
camera as a focal plane detector for a soft X-ray telescope (0.4-12 keV) and a non-focusing soft gamma-ray
detector (40-600 keV) . The micro-calorimeter system is developed by an international collaboration led
by ISAS/JAXA and NASA. The simultaneous broad bandpass, coupled with high spectral resolution of
ΔE ~7 eV provided by the micro-calorimeter will enable a wide variety of important science themes to be
pursued.
The Hard X-ray Imager (HXI) is one of four detectors on board the ASTRO-H mission (6th Japanese X-ray
satellite), which is scheduled to be launched in 2014. Using the hybrid structure composed of double-sided silicon
strip detectors and a cadmium telluride double-sided strip detector, the instrument fully covers the energy range
of photons collected with the hard X-ray telescope up to 80 keV with a high quantum efficiency. High spatial
resolution of 250 μm and an energy resolution of 1-2 keV (FWHM) are both achieved with low noise front-end
ASICs. In addition, the thick BGO active shields surrounding the main detector package is a heritage of the
successful performance of the Hard X-ray Detector on board the Suzaku satellite. This feature enables the
instrument to achieve an extremely high background reduction caused by cosmic-ray particles, cosmic X-ray
background, and in-orbit radiation activation. In this paper, we present the detector concept, design, latest
results of the detector development, and the current status of the hardware.
ASTRO-H is the next generation JAXA X-ray satellite, intended to carry instruments with broad energy coverage
and exquisite energy resolution. The Soft Gamma-ray Detector (SGD) is one of ASTRO-H instruments and will
feature wide energy band (40-600 keV) at a background level 10 times better than the current instruments on
orbit. SGD is complimentary to ASTRO-H's Hard X-ray Imager covering the energy range of 5-80 keV. The
SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield
where Compton kinematics is utilized to reject backgrounds. The Compton camera in the SGD is realized as
a hybrid semiconductor detector system which consists of silicon and CdTe (cadmium telluride) sensors. Good
energy resolution is afforded by semiconductor sensors, and it results in good background rejection capability due
to better constraints on Compton kinematics. Utilization of Compton kinematics also makes the SGD sensitive
to the gamma-ray polarization, opening up a new window to study properties of gamma-ray emission processes.
The ASTRO-H mission is approved by ISAS/JAXA to proceed to a detailed design phase with an expected
launch in 2014. In this paper, we present science drivers and concept of the SGD instrument followed by detailed
description of the instrument and expected performance.
We are developing imaging Cadmium Telluride (CdTe) pixel detectors optimized for astrophysical hard X-ray
applications. Our hybrid detector consist of a CdTe crystal 1mm thick and 2cm × 2cm in area with segmented
anode contacts directly bonded to a custom low-noise application specific integrated circuit (ASIC). The CdTe
sensor, fabricated by ACRORAD (Okinawa, Japan), has Schottky blocking contacts on a 605 micron pitch in a
32 × 32 array, providing low leakage current and enabling readout of the anode side. The detector is bonded
using epoxy-gold stud interconnects to a custom low noise, low power ASIC circuit developed by Caltech's
Space Radiation Laboratory. We have achieved very good energy resolution over a wide energy range (0.62keV
FWHM @ 60keV, 10.8keV FWHM @ 662keV). We observe polarization effects at room temperature, but they
are suppressed if we operate the detector at or below 0°C degree. These detectors have potential application for
future missions such as the International X-ray Observatory (IXO).
The Hard X-ray Imager (HXI) is one of three focal plane detectors on board the NeXT (New exploration X-ray
Telescope) mission, which is scheduled to be launched in 2013. By use of the hybrid structure composed of
double-sided silicon strip detectors and a cadmium telluride strip detector, it fully covers the energy range of
photons collected with the hard X-ray telescope up to 80 keV with a high quantum efficiency. High spatial
resolutions of 400 micron pitch and energy resolutions of 1-2 keV (FWMH) are at the same time achieved with
low noise front-end ASICs. In addition, thick BGO active shields compactly surrounding the main detection
part, as a heritage of the successful performance of the Hard X-ray Detector (HXD) on board Suzaku satellite,
enable to achive an extremely high background reduction for the cosmic-ray particle background and in-orbit
activation. The current status of hardware development including the design requirement, expected performance,
and technical readinesses of key technologies are summarized.
How structures of various scales formed and evolved from the early Universe up to present time is a fundamental
question of astrophysics. EDGE will trace the cosmic history of the baryons from the early generations of massive
stars by Gamma-Ray Burst (GRB) explosions, through the period of galaxy cluster formation, down to the very low
redshift Universe, when between a third and one half of the baryons are expected to reside in cosmic filaments undergoing
gravitational collapse by dark matter (the so-called warm hot intragalactic medium). In addition EDGE, with its
unprecedented capabilities, will provide key results in many important fields. These scientific goals are feasible with a
medium class mission using existing technology combined with innovative instrumental and observational capabilities
by: (a) observing with fast reaction Gamma-Ray Bursts with a high spectral resolution (R ~ 500). This enables the study
of their (star-forming) environment and the use of GRBs as back lights of large scale cosmological structures; (b)
observing and surveying extended sources (galaxy clusters, WHIM) with high sensitivity using two wide field of view
X-ray telescopes (one with a high angular resolution and the other with a high spectral resolution). The mission concept
includes four main instruments: a Wide-field Spectrometer with excellent energy resolution (3 eV at 0.6 keV), a Wide-
Field Imager with high angular resolution (HPD 15") constant over the full 1.4 degree field of view, and a Wide Field
Monitor with a FOV of 1/4 of the sky, which will trigger the fast repointing to the GRB. Extension of its energy response
up to 1 MeV will be achieved with a GRB detector with no imaging capability. This mission is proposed to ESA as part
of the Cosmic Vision call. We will briefly review the science drivers and describe in more detail the payload of this
mission.
The X-ray astronomical satellite Suzaku was successfully launched in July 2005. The onboard Wideband All-sky Monitor (WAM) is designed as the second function of the large, thick BGO anti-coincidence shields of the Hard X-ray Detectors (HXD). It views about half of the whole sky and has a geometrical area of 800 cm2 per side, with a large effective area of 400 cm2 even at 1 MeV. Hence, the WAM is expected to provide unique opportunities to detect high energy emission from GRBs and solar flares in the MeV range. In fact, the WAM has detected at least 47 GRBs, although the fine-tuning of the GRB functions is still in progress. The most impressive GRB result is the bright, hard spectrum GRB 051008, which was detected up to 1 MeV with the WAM. We will present here the in-flight performance of the HXD/WAM during the initial eight-months of operations. The in-flight energy response, spectral and timing capabilities, and in-orbit background are described in this paper.
We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe semiconductor Compton telescope are reported. The Compton telescope consists of a double-sided Si strip detector (DSSD) and CdTe pixel detectors, combined with low noise analog LSI, VA32TA. With this detector, we obtained Compton reconstructed images and spectra from line gamma-rays ranging from 81 keV up to 356 keV. The energy resolution is 3.8 keV and 7.9 keV at 122 keV and 356 keV, respectively, and the angular resolution is 9.9° and 5.7° at 122 keV and 356 keV, respectively.
KEYWORDS: Sensors, Hard x-rays, Calibration, Gamma radiation, Monte Carlo methods, Error analysis, X-ray telescopes, Coded apertures, Space telescopes, X-rays
In addition to providing the initial gamma-ray burst trigger and location, the Swift Burst Alert Telescope (BAT) will also perform an all-sky hard x-ray survey based on serendipitous pointings resulting from the study of gamma-ray bursts. BAT was designed with a very wide field-of-view (FOV) so that it can observe roughly 1/7 of the sky at any time. Since gamma-ray bursts are uniformly distributed over the sky, the final BAT survey coverage is expected to be nearly uniform. BAT's large effective area and long sky exposures will produce a 15 - 150 keV survey with up to 30 times better sensitivity than any previous hard x-ray survey (e.g. HEAO A4). Since the sensitivity of deep exposures in this energy range is systematics limited, the ultimate survey sensitivity depends on the relative sizes of the statistical and systematic errors in the data. Many careful calibration experiments were performed at NASA/Goddard Space Flight Center to better understand the BAT instrument's response to 15-150 keV gamma-rays incident from any direction within the FOV. Using radioactive sources of gamma-rays with known locations and energies, the Swift team can identify potential systematic errors in the telescope's performance and estimate the actual Swift hard x-ray survey sensitivity in flight. These calibration results will be discussed and a preliminary parameterization of the BAT instrument response will be presented. While the details of the individual BAT CZT detector response will be presented elsewhere in these proceedings, this talk will focus on the translation of the calibration experimental data into overall hard x-ray survey sensitivity.
The Burst Alert Telescope (BAT) aboard the Swift Gamma-ray Burst Explorer (scheduled for launch in January 2004) is a coded aperture telescope that includes an array of 32,768 CZT planar detectors, each 4 mm x 4 mm x 2 mm thick. The mobility-lifetime products for holes and electrons are used to characterize the charge transport properties of each detector and were measured during pre-flight calibration tests in early 2003. These values were found to vary over an order of magnitude from detector to detector. In addition to the charge transport models, other more empirical models are used to characterize the remaining components of the response of the BAT array to 15 - 150 keV gamma radiation from any direction in BAT's field-of-view (FOV). The full angular and spectral response of the array as a whole can be parameterized and the spectral response of the instrument over the range of angles and energies can thus be generated in an overall instrument response model. Here we present a preliminary instrument response model and discuss the general characteristics of the detector array. The software to generate the response matrix for BAT is currently under development.
The properties of 32k CdZnTe detectors have been studied in the
pre-flight calibration of Burst Alert Telescope (BAT) on-board the
Swift Gamma-ray Burst Explorer (scheduled for launch in January 2004).
After corrections of the linearity and the gain, the energy resolution
of summed spectrum is 7.0 keV (FWHM) at 122~keV. In order to construct
response matrices for the BAT instrument, we extracted
mobility-lifetime (μτ) products for electrons and holes in the
CdZnTe. Based on a new method applied to 57Co spectra taken at different bias voltages, μτ for electrons ranges from
5.0x10-4 to 1.0x10-2cm2V-1, while μτ for holes ranges from 1.0x10-5 to
1.7x10-4cm2V-1. We show that the distortion of the spectrum and the peak efficiency of the BAT instrument are well reproduced by the μτ database constructed in the calibration.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.