A novel optical scene simulation method is proposed in this paper which is designed for evaluating intelligent driving systems incorporating large-array flash lidars as the 3D detector. A 3D scene is first decomposed into discrete time slice patterns and displayed on a spatial light modulator. An integrated imaging system is then used to reconstruct all time slice patterns in space into a 3D scene. We have developed a 3D lidar scene simulator with a spatial resolution of 640×512 and a distance simulation range from 0.5 meters to 32 meters, achieving a distance simulation resolution of 15mm. The method proposed in this article can significantly reduce the time and space requirements for the end-of-line testing of lidar products on automated production lines and provides an effective approach for comprehensive performance evaluation in the field of intelligent driving systems.
Broadband light absorbers are attractive for their applications in photodetection and thermal detectors. Metal-black coatings have been experimentally proven to have broadband light absorption characteristic. A large area and broadband gold-black coating was fabricated by a low-cost but effective sputtering process. The gold-black films exhibited reduced reflection of 4.81%, 2.48% and 1.93% for sputtering pressure of 50, 65 and 80 Pa in 300-800 nm spectral range, and their size reached 4- inches. A three-dimensional nanocone-like array model was proposed for the gold-black films. Then, the nanocone array of this model was embedded with many gold nanoparticles due to the rough surface of the gold-black films. The results indicated this proposed model of nanocone-like array embedded with nanoparticles can be a good tool to design broadband gold-black absorbers.
In response to the current increasing demand for calibration of low-temperature infrared radiation sources with a large dynamic range, this paper studies a calibration method for low-temperature infrared radiation sources with a temperature range of 100-450K. The improvement of the signal-to-noise ratio of the input signal by related detection techniques is analyzed. Developed a radiation calibration device, also called a radiometer, analyzed the calibration and measurement process of the radiometer, and established a corresponding mathematical model. The experimental results show that the minimum radiation intensity that can be measured by the radiometer is 2.47×10-12 W, and the response rate of the radiometer is 102878.38 V/W. Use the calibrated radiometer to measure the target simulator. The source and contribution of the uncertainty of the radiometer in the measurement process are analyzed.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.