Paper
1 January 1981 Precision Radial Velocities And Residual Problems With Reticon Arrays
B. Campbell, G. A. H. Walker, R. Johnson, T. Lester, S. Yang, J. Auman
Author Affiliations +
Abstract
A program of precision radial velocity measurements using a RL1872 F/30 Reticon as detector and absorption lines of HF for reference (see Campbell and Walker 1979) is being pursued at both CFHT and at DAO, Victoria. While the long term accuracy of the technique will depend on the ability to duplicate and control the state of the HF gas in the absorption cell, oe can achieve a velocity precision in a single observation of a strong-lined star at 10 Å/mm dispersion, of ~15 ms-1 at a s/n ~1200. This corresponds to a displacement ~2.10-2 of a 15μ diode spacing. The critical instrumental and calibration techniques are discussed, in particular the temperature stability of the array, photometric calibration of the individual diodes and the measurement of individual diode to diode spacings.
© (1981) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
B. Campbell, G. A. H. Walker, R. Johnson, T. Lester, S. Yang, and J. Auman "Precision Radial Velocities And Residual Problems With Reticon Arrays", Proc. SPIE 0290, Solid-State Imagers for Astronomy, (1 January 1981); https://doi.org/10.1117/12.965863
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Absorption

Calibration

Stars

Diodes

Spectrographs

Astronomy

Telescopes

RELATED CONTENT

Development and construction of MAROON-X
Proceedings of SPIE (August 04 2016)
Ultra-High Precision Radial Velocity Spectrometer
Proceedings of SPIE (November 16 1982)
X shooter UV to K band intermediate resolution high...
Proceedings of SPIE (June 30 2006)
ESPRESSO: the ultimate rocky exoplanets hunter for the VLT
Proceedings of SPIE (September 24 2012)

Back to Top