Presentation + Paper
5 March 2021 Biomimetic 3D-printed fluorescence angiography phantoms for evaluation of neurosurgical microscopes
Author Affiliations +
Abstract
Cerebral saccular aneurysms represent a life-threatening condition that typically requires surgical intervention, often accomplished with a clip ligation approach across the aneurysm neck. Fluorescent angiography (FA) with indocyanine green (ICG) - a technique commonly used in neurosurgery – can be utilized to ensure that the neck of the aneurysm is fully ligated, while the adjacent vessels remain patent after clip placement. However, there is currently a lack of standardized performance test methods for surgical microscopes with FA capability. We have developed a 3D-printed, biomimetic aneurysm phantom with the potential to facilitate development and evaluation of these critical surgical instruments. Digital models of the Circle of Willis vasculature, including the multimodal imaging-based detailed anatomical (MIDA) model of the head and neck and a public domain model of a basilar tip aneurysm, were combined to generate a modular aneurysm phantom system. This system includes a basilar artery aneurysm and posterior communicator artery aneurysm phantoms. Non-fluorescent phantom components representing surrounding tissue were derived from the MIDA model. A stereolithography printer was used to create a solid vascular phantom from a custom turbid photopolymer doped with ICGsimulating dye. Feature sizes of printed components were found to be within 2.5% of digital models. Using a custom fluorescence imaging system, we were able to clearly visualize vessels and aneurysms amongst non-fluorescent background structures in the model. The methods for fabrication of a biomimetic neurovascular phantom incorporating realistic pathology have the potential to facilitate development, standardized bench testing and clinical training for intraoperative FA systems.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David Burgos, Bennett Blumenkopf, and Joshua Pfefer "Biomimetic 3D-printed fluorescence angiography phantoms for evaluation of neurosurgical microscopes", Proc. SPIE 11633, Design and Quality for Biomedical Technologies XIV, 1163309 (5 March 2021); https://doi.org/10.1117/12.2579357
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Angiography

Biomimetics

Microscopes

Aneurysms

Luminescence

3D modeling

3D printing

Back to Top