Poster + Paper
9 October 2021 Time serial development of optical performance of the myopic model mouse eyes
Xueqing Ding, Rui Qiu, Fengxian Du, Tianyang Zhao, Yilei Shao, Meixiao Shen, Qiang Wu, Cuixia Dai
Author Affiliations +
Conference Poster
Abstract
Myopia is a significant cause of visual impairment which may lead to many complications. Though the mechanism of myopia is not clear, the changes of the biological parameters and the optical performance of eyes were suggested as a key mechanism. In order to investigate the mechanism of myopia, in this paper, the time serial evaluation of biological parameters was performed and the optical performance of myopic model mouse eyes were evaluated by using optical coherence tomography (OCT) and ZEMAX software. The biological parameters were compared, and the optical performance of mouse eyes were evaluated in the myopic model mouse eyes, normal control mouse eyes and atropine-treated mouse eyes. The correlation analysis of the statistics indicated that the development of myopia was significantly related to the corneal curvature radius, center corneal thickness, vitreous depth and axial length (P<0.05). The analysis of biological parameters proved that the peripheral RMS wavefront aberration of eyes played more crucial roles in the development of myopia than the center parameters, and the degree of myopia would be proofed by the hyperopic wavefront aberration. The myopic model mouse eyes had larger corneal curvature radius, thicker center corneal thickness, deeper vitreous depth and longer axial length than normal mouse eyes. The experimental results of atropine-treated eyes suggested that atropine could relieve myopia and eye enlargement via a nonaccommodative mechanism. This study provides a new method for evaluations of the optical performance of eyes and the study of myopia.
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xueqing Ding, Rui Qiu, Fengxian Du, Tianyang Zhao, Yilei Shao, Meixiao Shen, Qiang Wu, and Cuixia Dai "Time serial development of optical performance of the myopic model mouse eyes", Proc. SPIE 11900, Optics in Health Care and Biomedical Optics XI, 119002W (9 October 2021); https://doi.org/10.1117/12.2602191
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Eye models

Optical coherence tomography

Fused deposition modeling

Zemax

Eye

Wavefront aberrations

Performance modeling

Back to Top