Presentation + Paper
10 April 2023 Multi-angled simultaneous biplane High-Speed Angiography (HSA) of patient-specific 3D-printed aneurysm phantoms using 1000 fps CdTe Photon-Counting Detectors (PCD’s)
Author Affiliations +
Abstract
1000 fps HSA enables visualization of flow details, which may be important in accurately guiding interventional procedures; however, single-plane imaging may lack clear visualization of vessel geometry and flow detail. The previously presented high-speed orthogonal biplane imaging may overcome these limitations but may still result in foreshortening of vessel morphology. In certain morphologies, acquiring two non-orthogonal biplane projections at multiple angles can provide better flow detail rather than a standard orthogonal biplane acquisition. Flow studies of aneurysm models were performed, where simultaneous biplane acquisitions at various angles separating the two detector views allowed for better evaluation of morphology and flow. 3D-printed, patient-specific internal carotid artery aneurysm models were imaged with various non-orthogonal angles between the two high-speed photon-counting detectors (7.5 cm x 5 cm FOV) to provide frame-correlated simultaneous 1000-fps image sequences. Fluid dynamics were visualized in multi-angled planes of each model using automated injections of iodine contrast media. The resulting dual simultaneous frame-correlated 1000-fps acquisitions from multiple planes of each aneurysm model provided improved visualization of complex aneurysm geometries and flow streamlines. Multi-angled biplane acquisitions with frame correlation allows for further understanding of aneurysm morphology and flow details: additionally, the ability to recover fluid dynamics at depth enables accurate analysis of 3D flow streamlines, and it is expected that multiple-planar views will enable better volumetric flow visualization and quantification. Such better visualization has the potential to improve interventional procedures.
Conference Presentation
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
E. Vanderbilt, X. Wu, A. Shields, S. V. Setlur Nagesh, C. Ionita, D. R. Bednarek, and S. Rudin "Multi-angled simultaneous biplane High-Speed Angiography (HSA) of patient-specific 3D-printed aneurysm phantoms using 1000 fps CdTe Photon-Counting Detectors (PCD’s)", Proc. SPIE 12468, Medical Imaging 2023: Biomedical Applications in Molecular, Structural, and Functional Imaging, 124680M (10 April 2023); https://doi.org/10.1117/12.2653136
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Aneurysms

Video

Visualization

Angiography

X-rays

Single photon detectors

X-ray detectors

Back to Top