Paper
1 June 1990 Automatic on-line wafer stepper calibration system
Martin A. van den Brink, Hans Franken, Stefan Wittekoek, Theo Fahner
Author Affiliations +
Abstract
This paper introduces a new wafer stepper on-line calibration sensor, the Image Sensor, which refers directly to the aerial reticle image at the exposure wavelength. This sensor system is integrated with other stepper metrology systems by a so-called Image Sensor fiducial plate, which interacts simultaneously with the aerial reticle image, the Image Sensor, the TTL alignment system and the focus sensor of the stepper. An integrated software package ensures on-line regular stepper calibration, eliminating dependance on environmental, process and time parameters. Unique in this concept is the direct measurement of the consequence of wavelength drift in excimer laser steppers by measuring the aerial image deformation at the exposure wavelength. This information is used as a direct feedback to the wavelength control of the laser. Initial results of this system are presented for both UV (365 nm) and DUV (248 nm) steppers.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Martin A. van den Brink, Hans Franken, Stefan Wittekoek, and Theo Fahner "Automatic on-line wafer stepper calibration system", Proc. SPIE 1261, Integrated Circuit Metrology, Inspection, and Process Control IV, (1 June 1990); https://doi.org/10.1117/12.20056
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image sensors

Sensors

Semiconducting wafers

Metrology

Calibration

Reticles

Monochromatic aberrations

RELATED CONTENT

0.7 NA DUV step and scan system for 150 nm...
Proceedings of SPIE (July 26 1999)
Aerial image sensor for self-calibration of wafer steppers
Proceedings of SPIE (September 14 2001)
Deep UV wafer stepper with through the lens wafer to...
Proceedings of SPIE (June 01 1990)
Latent image metrology for production wafer steppers
Proceedings of SPIE (May 26 1995)
SMART SET An Integrated Approach to Stepper Set...
Proceedings of SPIE (January 02 1986)

Back to Top