Presentation + Paper
29 March 2024 Can patient-specific acquisition protocol improve performance on defect detection task in myocardial perfusion SPECT?
Author Affiliations +
Abstract
Myocardial perfusion imaging using single-photon emission computed tomography (SPECT), or myocardial perfusion SPECT (MPS) is a widely used clinical imaging modality for the diagnosis of coronary artery disease. Current clinical protocols for acquiring and reconstructing MPS images are similar for most patients. However, for patients with outlier anatomical characteristics, such as large breasts, images acquired using conventional protocols are often sub-optimal in quality, leading to degraded diagnostic accuracy. Solutions to improve image quality for these patients outside of increased dose or total acquisition time remain challenging. Thus, there is an important need for new methodologies that can help improve the quality of the acquired images for such patients, in terms of the ability to detect myocardial perfusion defects. One approach to improving this performance is adapting the image acquisition protocol specific to each patient. Studies have shown that in MPS, different projection angles usually contain varying amounts of information for the detection task. However, current clinical protocols spend the same time at each projection angle. In this work, we evaluated whether an acquisition protocol that is optimized for each patient could improve performance on the task of defect detection on reconstructed images for patients with outlier anatomical characteristics. For this study, we first designed and implemented a personalized patient-specific protocol-optimization strategy, which we term precision SPECT (PRESPECT). This strategy integrates the theory of ideal observers with the constraints of tomographic reconstruction to optimize the acquisition time for each projection view, such that performance on the task of detecting myocardial perfusion defects is maximized. We performed a clinically realistic simulation study on patients with outlier anatomies on the task of detecting perfusion defects on various realizations of low-dose scans by an anthropomorphic channelized Hotelling observer. Our results show that using PRESPECT led to improved performance on the defect detection task for the considered patients. These results provide evidence that personalization of MPS acquisition protocol has the potential to improve defect detection performance on reconstructed images by anthropomorphic observers for patients with outlier anatomical characteristics. Thus, our findings motivate further research to design optimal patient-specific acquisition and reconstruction protocols for MPS, as well as developing similar approaches for other medical imaging modalities.
Conference Presentation
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Nu Ri Choi, Md Ashequr Rahman, Zitong Yu, Barry A. Siegel, and Abhinav K. Jha "Can patient-specific acquisition protocol improve performance on defect detection task in myocardial perfusion SPECT?", Proc. SPIE 12929, Medical Imaging 2024: Image Perception, Observer Performance, and Technology Assessment, 129290O (29 March 2024); https://doi.org/10.1117/12.3006924
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Anatomy

Defect detection

Medical image reconstruction

Information operations

Single photon emission computed tomography

Breast

Computed tomography

Back to Top