Paper
28 July 1994 Performance and use of paracorporeal fiber optic blood gas sensors
Roy C. Martin D.V.M., Stephen F. Malin, Daniel J. Bartnik, Anne Schilling, Steven C. Furlong
Author Affiliations +
Proceedings Volume 2131, Biomedical Fiber Optic Instrumentation; (1994) https://doi.org/10.1117/12.180740
Event: OE/LASE '94, 1994, Los Angeles, CA, United States
Abstract
The SensiCathTM arterial blood gas (ABG) monitoring system allows rapid blood gas and pH measurements using fiber optic sensors in a paracorporeal device. The paracorporeal device location allows blood to be withdrawn from a vascular access, measured and returned to a patient, without direct handling and blood loss associated with traditional sampling techniques. The disposable device contains three fiber optic sensors and one temperature sensor. The sensors are monitored using a three-channel, solid-state instrument of minimal size and weight. Measurements of pH, pCO2, and pO2 are made at the point of care, on demand, with results available in 60 seconds. Calibration is performed using two prepackaged, sterile, nontoxic, nonpyrogenic solutions. The paracorporeal location allows access for calibration before or during patient utilization, and for quality assurance checks at any time during use. Laboratory data are presented which assess precision and accuracy of the SensiCath system by comparing its performance measured against tonometered gases and a calibrated pH glass electrode. In vivo animal data using a rabbit model indicate the SensiCath system performance is compared against two independent standard blood gas analyzers. The clinical utility of the SensiCath system incorporated into standard arterial lines is discussed.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Roy C. Martin D.V.M., Stephen F. Malin, Daniel J. Bartnik, Anne Schilling, and Steven C. Furlong "Performance and use of paracorporeal fiber optic blood gas sensors", Proc. SPIE 2131, Biomedical Fiber Optic Instrumentation, (28 July 1994); https://doi.org/10.1117/12.180740
Lens.org Logo
CITATIONS
Cited by 31 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Blood

Sensors

Calibration

Animal model studies

Fiber optics sensors

Statistical analysis

Gas sensors

RELATED CONTENT

Field testing of a portable fiber optic chemical sensor
Proceedings of SPIE (January 19 1995)
IR fiber optic evanescent field sensors for gas monitoring
Proceedings of SPIE (September 29 1995)
Fiber optic plethysmography
Proceedings of SPIE (August 01 1992)
Continuous blood gas monitoring in femoral arteries
Proceedings of SPIE (May 08 1995)

Back to Top