Paper
12 May 1995 Comparison of CO2 laser welding with suture technique for repair of tendons
Neven A. Popovic M.D., Frederic L. Johnstone M.D., Francis X. Kilkelly M.D., LuAnn McKinney D.V.M., Willem Pieter Van De Merwe, Allan C. Smith M.D.
Author Affiliations +
Abstract
The purpose of this study was to evaluate the efficacy, histology, and strength of laser welding in repair of sharply transected rat Achilles tendons. In 26 adult, male Sprague-Dawley rats, the severed tendons were repaired with a 7-0 nylon, modified Kessler core suture followed by either a running 9-0 nylon epitendinous suture or a circumferential CO2 laser epidendinous weld using 25% human albumin as a solder. All repairs were timed and post- operative tensile strength was analyzed with material testing equipment. In addition, histologic testing was performed on both types of repairs. The mean time to complete the epitendinous repair in the laser group was 3.5 minutes and in the suture group, 8 minutes. The mean ultimate tensile strength in 6 normal tendons was 40.9 Newtons (N) with group standard deviation of 5.2 N. When compared with normal controls, post-operatively both types of tendon repairs resulted in tensile failure at lower forces. The ultimate tensile strength for the epitendinous suture repair and the laser welds were 13% and 6% of normal controls, respectively. Twenty tendons with epidendinous suture repair had mean ultimate tensile strength of 5.4 (+/- 1.2) N, while the 17 tendons with laser wends failed at 2.6 (+/- 0.9) N. Histologic evaluation of tendons repaired with CO2 laser revealed areas of coagulation and edema on the surface of tendon edges. Post-operatively, greater tissue changes were noted in laser treated tendons than those repaired with sutures. Laser welding of epitenon is possible and can be completed faster than the suture repair. The repaired tendon surface appears smoother and less bulky after laser treatment. However, significantly decreased immediate post-operative strength was demonstrated by the use of Kruskal-Wallis one way analysis of variance and Turkey's pairwise comparison.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Neven A. Popovic M.D., Frederic L. Johnstone M.D., Francis X. Kilkelly M.D., LuAnn McKinney D.V.M., Willem Pieter Van De Merwe, and Allan C. Smith M.D. "Comparison of CO2 laser welding with suture technique for repair of tendons", Proc. SPIE 2395, Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems V, (12 May 1995); https://doi.org/10.1117/12.209138
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Laser tissue interaction

Laser welding

Carbon dioxide lasers

Control systems

Collagen

Natural surfaces

Back to Top