Paper
7 May 1997 Integrated distortion correction and reconstruction technique for digital mosaic mammography
Vivek Swarnakar, Myoungki Jeong, Richard M. Wasserman, Eric Andres, Darold C. Wobschall
Author Affiliations +
Abstract
Investigations in the area of digital mammography have been limited by the resolution of the sensor devices employed. We have proposed a multiple camera or mosaic architecture in which adjacent sensors observe an overlapping field of view. Such a technique can deliver extremely high resolution while simultaneously maintaining a moderate cost for the resultant instrument. However, this technique's clinical efficacy will be limited by the ability to accurately and precisely reconstruct a single continuous image from multiple CCD sensors. We present an integrated algorithm which will correct distortions introduced by the camera while addressing the problem of image reconstruction or 're- stitching.' Such a technique will minimize pixel loss by limiting image re-sampling to a single incident. Custom designed calibration screens were employed for the calculation of camera distortion and intra-camera disparity. A parallel digital signal processor architecture has been developed to accelerate system performance when employing a large number of camera inputs. We present a quantitative evaluation of our reconstruction technique and an analysis with respect to similar methods of image reconstruction. We have previously constructed and presented a prototype imager for digital radiography based upon a similar sensor architecture. The algorithm presented will significantly enhance the feasibility of our multiple camera architecture for both digital radiography and mammography. We believe that such a methodology will enhance diagnostic accuracy at a moderate cost when compared with system of similar imaging resolution.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Vivek Swarnakar, Myoungki Jeong, Richard M. Wasserman, Eric Andres, and Darold C. Wobschall "Integrated distortion correction and reconstruction technique for digital mosaic mammography", Proc. SPIE 3031, Medical Imaging 1997: Image Display, (7 May 1997); https://doi.org/10.1117/12.273949
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Distortion

Digital mammography

Digital imaging

CCD image sensors

Imaging systems

Cameras

Mammography

RELATED CONTENT

Image processing techniques for digital breast imaging
Proceedings of SPIE (November 14 1996)
Highest resolution image acquisition
Proceedings of SPIE (December 29 1993)
Spatial noise suppression for LCD displays
Proceedings of SPIE (September 11 2009)

Back to Top