19 May 1999 Improved quantitative MR thermometry using a 1.5-T scanner to monitor cooled applicator systems during laser-induced interstitial thermotherapy (LITT)
Harald Busse, Margarethe Rassek, Andreas Grust, Thomas Kahn M.D., Hans-Joachim Schwarzmaier M.D.
Author Affiliations +
Proceedings Volume 3594, Thermal Treatment of Tissue with Image Guidance; (1999) https://doi.org/10.1117/12.348739
Event: BiOS '99 International Biomedical Optics Symposium, 1999, San Jose, CA, United States
Abstract
Cooled LITT applicator systems are known to induce complex temperature patterns. Typical for such devices, the temperature maxima are often shifted away from the applicator into the tissue. Therefore, an adequate temperature monitoring is essential. This, however, has not yet been realized for many of the latest MRI systems. We have implemented an improved MR thermometry system using a gradient echo pulse sequence (5 mm slice, FOV 230 mm, TR/TE equals 80/26 ms, matrix 192 X 256) on a 1.5 T scanner (Magnetron Vision, Siemens, Erlangen, Germany). The recorded temperature expansion during laser irradiation of bovine liver was used as a model setup for LITT. A commercially available water-cooled applicator system (Microdome light guide, Huettinger, Umkirch, Germany, in combination with the Power Catheter, Somatex, Berlin, Germany) was used for the delivery of the Nd:YAG laser radiation ((lambda) equals 1064 nm, cw, 15.5 W, Dornier 4060N, Germering, Germany) and tissue cooling, respectively. MR phase images were recorded every 30 seconds alternating in axial and radial orientation. The temperature distributions were calculated using the proton resonance frequency method. A sensitivity factor of 0.0097 ppm/ degree(s)C has been determined independently by a comparison with fluorooptic temperature measurements. The temperature accuracy of a single pixel (0.9 mm square) during 10 min laser irradiation of bovine liver tissue was found to be (-1.7 +/- 1.4) degree(s)C. The final lesion size diameters after 6 min laser irradiation (15 mm X 26 mm) were found to be in good agreement with the dimensions of the 60 degree(s)C isotherm of the respective 2D temperature map. This indicates that the implemented MR thermometry might be an essential tool for therapy control of interstitial laser treatment with cooled applicator systems.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Harald Busse, Margarethe Rassek, Andreas Grust, Thomas Kahn M.D., and Hans-Joachim Schwarzmaier M.D. "Improved quantitative MR thermometry using a 1.5-T scanner to monitor cooled applicator systems during laser-induced interstitial thermotherapy (LITT)", Proc. SPIE 3594, Thermal Treatment of Tissue with Image Guidance, (19 May 1999); https://doi.org/10.1117/12.348739
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Temperature metrology

Thermometry

Magnetic resonance imaging

Laser irradiation

Liver

Tissues

Scanners

Back to Top