Paper
17 September 1999 Analysis of the equivalence of four models in OCT simulation
Jiansong Gao, Ping Xue, Tao Yuan, Lei Wang, Die Yan Chen
Author Affiliations +
Proceedings Volume 3863, 1999 International Conference on Biomedical Optics; (1999) https://doi.org/10.1117/12.364396
Event: International Symposium on Biomedical Optics, 1999, Wuhan, China
Abstract
Monte Carlo method is employed to simulate optical path-length- resolved reflectance from samples in optical coherence tomography. Four different models are often used in such simulations to treat the scattering and absorption process. This paper presents a detailed probability analysis on the equivalence of the four different models under certain conditions. We found that the photon's statistical contributions after the same times of scattering are equal in these four models.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.