Paper
18 July 2000 X-ray imaging spectrometers for Astro-E: ground calibration in the soft x-ray range
Kiyoshi Hayashida, Shunji Kitamoto, Emi Miyata, Hiroshi Tsunemi, Kumi Yoshita, Takayoshi Kohmura, Kouji Mori, Kazunori Katayama, Haruyoshi Katayama, Makoto Shouho, Motoari Ohta, Tadayasu Dotani, Masanobu Ozaki, Katsuji Koyama, Hisamitsu Awaki, Takeshi G. Tsuru, George R. Ricker Jr., Mark W. Bautz, Richard F. Foster, Steven E. Kissel
Author Affiliations +
Abstract
Soft X-ray response of X-ray Imaging Spectrometers (XIS) for the Astro-E satellite is measured with a grating spectrometer system at Osaka. First, relation between incident X-ray energy and output pulse height peak (E-PH relation) is examined with an SX grating. It is found that jump in the E-PH relation around Si-K edge is at most 2.7 eV. Second, quantum efficiency (QE) of the XIS in 0.4 - 2.2 keV range is measured relatively to the reference CCD of which absolute QE was calibrated with a gas proportional counter. The QE is fitted with a model in which CCD gate structures are considered. Systematic error on the QE results is estimated by referring an independent measurement. Third, tuning and improvement of the response function is performed. We employ six components to reproduce the response profile of the XIS. In this paper, improvement of one component which is originated in the events absorbed in the channel-stop is presented. Nevertheless, Astro-E was lost due to the launch failure. We overview the XIS project in its flight model phase, modified points of the design, problems and solutions etc., in order to be utilized in a possible recovery of the satellite.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kiyoshi Hayashida, Shunji Kitamoto, Emi Miyata, Hiroshi Tsunemi, Kumi Yoshita, Takayoshi Kohmura, Kouji Mori, Kazunori Katayama, Haruyoshi Katayama, Makoto Shouho, Motoari Ohta, Tadayasu Dotani, Masanobu Ozaki, Katsuji Koyama, Hisamitsu Awaki, Takeshi G. Tsuru, George R. Ricker Jr., Mark W. Bautz, Richard F. Foster, and Steven E. Kissel "X-ray imaging spectrometers for Astro-E: ground calibration in the soft x-ray range", Proc. SPIE 4012, X-Ray Optics, Instruments, and Missions III, (18 July 2000); https://doi.org/10.1117/12.391548
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Charge-coupled devices

Quantum efficiency

Calibration

Fermium

Frequency modulation

Spectrometers

RELATED CONTENT

Soft X-ray Imager (SXI) onboard ASTRO-H
Proceedings of SPIE (July 29 2014)
In-orbit performance of SXT aboard AstroSat
Proceedings of SPIE (July 18 2016)
Soft x ray response of x ray CCD camera XIS...
Proceedings of SPIE (October 11 2004)
Soft x ray response of the prototype CCD camera (XIS)...
Proceedings of SPIE (November 10 1998)
Soft x-ray imager (SXI) onboard ASTRO-H
Proceedings of SPIE (September 17 2012)
Flight CCD selection for the x ray CCD camera of...
Proceedings of SPIE (February 03 2004)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)

Back to Top