6 May 2004 Assessment of breast lesions on stereoscopic and monoscopic digital specimen mammograms: an ROC study
Heang-Ping Chan, Mitch M. Goodsitt, Mark A. Helvie, Lubomir M. Hadjiiski, Justin T. Lydick, Marilyn A. Roubidoux, Janet E. Bailey, Alexis Nees, Caroline E. Blane, Joseph Shen, Michelle Foster, Berkman Sahiner
Author Affiliations +
Abstract
An ROC study was conducted to evaluate the usefulness of assessing breast lesion characteristics with stereomammography. Stereoscopic image pairs of 158 breast biopsy tissue specimens were acquired with a GE digital mammography system. Two stereo image pairs were taken at 1.8X magnification geometry and at approximately orthogonal orientations for each specimen. Display software was developed for a high resolution MegaScan CRT monitor driven by a DOME stereo display board. The specimens contained either a mass, microcalcifications, both, or normal tissue. About 40% of the specimens were found to contain malignancy by pathological analysis. Five MQSA radiologists participated in the observer performance experiment. The two views of each specimen were read independently and were separated by a large number of other specimen images to reduce any effects of memorization. Each observer read 316 specimen images in a systematically randomized order. The observer first read the monoscopic image and entered his/her assessment in terms of the confidence ratings on the presence of microcalcifications and/or masses, margin clearance, BI-RADS assessment, and the likelihood of malignancy. The corresponding stereoscopic images were then displayed on the same monitor and were viewed through stereoscopic LCD glasses. The observer was free to change the ratings in every category after stereoscopic reading. The ratings of the observers were analyzed by ROC methodology. For the 5 MQSA radiologists, the average Az value for estimation of the likelihood of malignancy of the lesions improved from 0.70 for monoscopic viewing to 0.72 (p<0.05) after stereoscopic viewing, and the average Az value for the presence of microcalcifications improved from 0.94 to 0.95 (p<0.05). The Az value for the presence of masses improved from 0.80 to 0.82 after stereoscopic viewing, but the difference fell short of statistical significance (p=0.08). The visual assessment of margin clearance was found to have very low correlation with pathological analysis. This study demonstrates the potential of using stereomammography to improve the detection and characterization of mammographic lesions.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Heang-Ping Chan, Mitch M. Goodsitt, Mark A. Helvie, Lubomir M. Hadjiiski, Justin T. Lydick, Marilyn A. Roubidoux, Janet E. Bailey, Alexis Nees, Caroline E. Blane, Joseph Shen, Michelle Foster, and Berkman Sahiner "Assessment of breast lesions on stereoscopic and monoscopic digital specimen mammograms: an ROC study", Proc. SPIE 5368, Medical Imaging 2004: Physics of Medical Imaging, (6 May 2004); https://doi.org/10.1117/12.535998
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Breast

Mammography

Digital imaging

Digital mammography

LCDs

Radiography

Back to Top