20 May 2005 Wavelength comparison study for bioaerosol detection
Steven D. Campbell, David P. Tremblay, Freddie Daver, Daniel Cousins
Author Affiliations +
Abstract
This paper reports on an investigation into optimal excitation and emission wavelengths for bioaerosol detection. Excitation/Emission Matrix (EEM) fluorescence data were gathered for a variety of materials, including biowarfare (BW) simulants, cell constituents, growth media and known interferents. These data were used to investigate multi-wavelength discrimination algorithms using pattern classification techniques. The results suggest that using two excitation wavelengths and narrower emission bands can improve discrimination between BW agents and interferents.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steven D. Campbell, David P. Tremblay, Freddie Daver, and Daniel Cousins "Wavelength comparison study for bioaerosol detection", Proc. SPIE 5778, Sensors, and Command, Control, Communications, and Intelligence (C3I) Technologies for Homeland Security and Homeland Defense IV, (20 May 2005); https://doi.org/10.1117/12.610998