Non-contact is the only way used in real-time measurement of object surface temperature at dynamic state. Pyroelectric crystal material is heat-variable detector that is sensitive to temperature difference, but when temperature of detected object is close to or equal to that of ambient temperature, noise coefficient of using pyroelectric crystal material to measure difference is very prominent, so measurement accuracy can be reduced or measurement meaning is lost. This paper puts forward temperature difference compare method using precise refrigeration temperature as reference. Measurement of detected temperature at normal temperature using this method can not only overcome low SNR (Signal Noise Ratio) problem caused by small measurement temperature difference, but also compensate measurement error caused by ambient temperature changes. Based on measuring temperature characteristics of pyroelectric material, it is generally required that high SNR can be acquired only when temperature difference between refrigeration reference temperature and detected object temperature is more than 3°C.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kebao Xu, Xiaojun Ju, Ping Zhu, and Juncheng Wang "Real-time running workpiece temperature measurement at room temperature with refrigeration reference", Proc. SPIE 6280, Third International Symposium on Precision Mechanical Measurements, 62803S (13 October 2006); https://doi.org/10.1117/12.716336
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Temperature metrology

Crystals

Infrared radiation

Signal detection

Thermography

Signal to noise ratio

Infrared detectors

RELATED CONTENT

Infrared thermography processing using Markov-PCA algorithm
Proceedings of SPIE (December 18 2014)
Infrared in the next millennium: detected thermal contrast
Proceedings of SPIE (November 16 2000)
Industrial Limitations Of Infrared Detectors
Proceedings of SPIE (December 17 1979)
Influence of thermal radiations in infrared optical systems
Proceedings of SPIE (February 10 2005)
Pyroelectrics In A Harsh Environment
Proceedings of SPIE (August 15 1988)

Back to Top