12 March 2007 The application of the principle of conserved myocardium volume in guiding automated chamber estimation in mouse cardiac imaging
Author Affiliations +
Abstract
Active contours have been used in a wide variety of image processing applications due to their ability to effectively distinguish image boundaries with limited user input. In this paper, we consider 3D gradient vector field (GVF) active surfaces and their application in the determination of the volume of the mouse heart left ventricle. The accuracy and efficacy of a 3D active surface is strongly dependent upon the selection of several parameters, corresponding to the tension and rigidity of the active surface and the weight of the GVF. However, selection of these parameters is often subjective and iterative. We observe that the volume of the cardiac muscle is, to a good approximation, conserved through the cardiac cycle. Therefore, we propose using the degree of conservation of heart muscle volume as a metric for assessing optimality of a particular set of active surface parameters. A synthetic dataset consisting of nested ellipsoids of known volume was constructed. The outer ellipsoid contracted over time to imitate a heart cycle, and the inner ellipsoid compensated to maintain constant volume. The segmentation algorithm was also investigated in vivo using B-mode data sets obtained by scanning the hearts of three separate mice. Active surfaces were initialized using a broad range of values for each of the parameters under consideration. Conservation of volume was a useful predictor of the efficacy of the model for the range of values tested for the GVF weighting parameter, though it was less effective at predicting the efficacy of the active surface tension and rigidity parameters.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christopher D. Garson, Bing Li, and John A. Hossack "The application of the principle of conserved myocardium volume in guiding automated chamber estimation in mouse cardiac imaging", Proc. SPIE 6513, Medical Imaging 2007: Ultrasonic Imaging and Signal Processing, 651312 (12 March 2007); https://doi.org/10.1117/12.716067
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Data modeling

In vivo imaging

Heart

3D modeling

Image segmentation

3D image processing

Cardiac imaging

Back to Top