26 April 2007 Mid-infrared laser ablation of intraocular acrylic lenses
E. Spyratou, M. Makropoulou, C. Bacharis, A. A. Serafetinides
Author Affiliations +
Abstract
Ablation rates measurements with free-running Er:YAG laser (λ=2.94 μm) were performed in hydrophilic acrylic intraocular lenses. We studied the role of water in the laser ablation mechanisms by using hydrophilic lenses with different concentrations of H20 and D20. A mathematical model simulated the experimental results.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
E. Spyratou, M. Makropoulou, C. Bacharis, and A. A. Serafetinides "Mid-infrared laser ablation of intraocular acrylic lenses", Proc. SPIE 6535, Saratov Fall Meeting 2006: Optical Technologies in Biophysics and Medicine VIII, 653524 (26 April 2007); https://doi.org/10.1117/12.741081