20 November 2009 A soft x-ray streak tube designed for ICF
Li Gu, Qinlao Yang
Author Affiliations +
Abstract
Electron optical analysis and simulation of the streak tube is completed, which is a core component of the camera system for ICF investigation. Principles and methods of the streak tube are applied to design the tube. The tube structure and voltage parameters are obtained according to electron optical theory. Multiple important evaluation parameters are also obtained through computer simulation and numerical analysis of the model. Results reveal that the designed image tube has a time resolution better than 11ps, sweep time distortion better than 43ps and space distortion smaller than 4%. Moreover, it also has a good spatial resolution. The steak tube is fabricated, static performance is tested and experimental data is analyzed. The experimental results show that the tube has a good static performance and meet the design requirements.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Li Gu and Qinlao Yang "A soft x-ray streak tube designed for ICF", Proc. SPIE 7511, 2009 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Systems, 75111V (20 November 2009); https://doi.org/10.1117/12.838112
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Distortion

Imaging systems

Electrodes

Computing systems

Image processing

Cameras

RELATED CONTENT

Analysis of 3D scene using structured light technique
Proceedings of SPIE (October 07 2011)
Dynamic Image Generation
Proceedings of SPIE (September 01 1975)
Portable digital radiographic imager: an overview
Proceedings of SPIE (April 11 1996)

Back to Top