22 March 2010 Head and body CTDIw of dual-energy x-ray CT with fast-kVp switching
Author Affiliations +
Abstract
Dual-energy CT has attracted much attention in recent years. Most recently, a fast-kVp switching (FKS) dual-energy method has been presented with clinical and phantom results to demonstrate its efficacy. The purpose of our study was to quantitatively compare the CTDIW of FKS and routine CT exams under the body and head conditions. For a fair comparison, the low contrast detectability (LCD) was matched before measuring dose. In FKS protocols, an x-ray generator switch rapidly between 140kVp and 80kVp in adjacent views, and the effective tube current is around 600mA. In addition to the tube voltage and current, the flux ratio between high and low kVp is optimized by asymmetric sampling of 35%-65%. The head and body protocols further differ by the gantry speed (0.9sec/1.0sec) and type of bowtie filter (head/body). For baseline single-energy, we followed the IEC standard head and body protocols (120kV, 1sec, 5mm) but iteratively adjusted the tube current (mA) in order to match the LCD. CTDIW was measured using either a 16 cm (for head scanning) or a 32 cm (for body scanning) PMMA phantom of at least 14 cm in length. The LCD was measured using the water section of Catphan 600. To make the study repeatable, the automated statistical LCD measurement tool available on GE Discovery CT750 scanner was used in this work. The mean CTDIW for the head and body single-energy acquisitions were 57.5mGy and 29.2mGy, respectively. The LCD was measured at 0.45% and 0.42% (slice thickness=5mm, object size=3mm, central 4 images), respectively. The average CTDIW for FKS head and body scans was 70.4mGy and 33.4mGy, respectively, at the optimal monochromatic energy of 65 keV. The corresponding LCD was measured at 0.45% and 0.43%, respectively. This demonstrates that, with matching LCD, CTDIW of FKS is comparable to that of routine CT exams under head and body conditions.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Baojun Li, Girijesh Yadava, Jiang Hsieh, Naveen Chandra, and Mary Sue Kulpins "Head and body CTDIw of dual-energy x-ray CT with fast-kVp switching", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76221Y (22 March 2010); https://doi.org/10.1117/12.844314
Lens.org Logo
CITATIONS
Cited by 14 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
LCDs

Head

X-rays

X-ray computed tomography

Switching

Computed tomography

Abdomen

Back to Top