22 March 2010 Low dose, low noise, and high resolution volume of interest (VOI) imaging in C-arm flat-detector CT
Author Affiliations +
Abstract
The high flexibility of C-arm flat-detector computed tomography (FDCT) is used in a volume of interest (VOI) imaging method to handle the challenges of increasing spatial resolution, reducing noise and saving dose. A low-dose overview scan of the object and a high-dose scan of an arbitrary VOI are combined. The first scan is adequate for orientation to select the VOI and the second scan assures high image quality in the VOI. The combination is based on a forward projection of the reconstructed overview volume and the measured VOI data in the raw data domain. Differences in the projection values are matched before a standard Feldkamp-type reconstruction is performed. In simulations, spatial resolution, noise and contrast detectability were evaluated. Measurements of an anthropomorphic phantom were used to validate the proposed method for realistic application. In Monte Carlo dose simulations the dose reduction potential was investigated. By combination of the two scans an image is generated which covers the whole object and provides the actual VOI at high image quality. Spatial resolution was increased whereas noise was decreased from outside to inside the VOI, e.g. for the simulations from 0.8 lp/mm to 3.0 lp/mm and from 39 HU to 18 HU, respectively. Simultaneously, the cumulative dose for this two-scan procedure was significantly reduced in comparison to a conventional high dose scan, e.g. for the performed simulations and measurements by about 95 %. The proposed VOI approach offers significant benefits with respect to high-resolution and low-contrast imaging of a VOI at reduced dose.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel Kolditz, Yiannis Kyriakou, and Willi A. Kalender "Low dose, low noise, and high resolution volume of interest (VOI) imaging in C-arm flat-detector CT", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 762226 (22 March 2010); https://doi.org/10.1117/12.844129
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

Monte Carlo methods

Spatial resolution

Computed tomography

Sensors

Image resolution

Data acquisition

Back to Top