Paper
3 March 2012 Dual energy CT-based characterization of x-ray attenuation properties of breast equivalent material plates
N. Geeraert, R. Klausz, P. Giudici, S. Muller, L. Cockmartin, H. Bosmans
Author Affiliations +
Abstract
Breast density is more and more considered as an important risk factor for breast cancer and several quantitative breast density evaluation methods have been proposed. The reference material for simulation of the breast attenuation properties of glandular and adipose breast tissues is manufactured by a single provider. In order to characterize the attenuation properties of these materials, measurements in Hounsfield Units (HU) have been performed using a CT-scanner. Breastequivalent plates have been imaged in different configurations (plates in and orthogonal to image planes), providing consistent results (± 1.3 HU). Breast density equivalent plates of different nominal breast density equivalences and sizes were measured, demonstrating both a good homogeneity within the plates (± 1.8 HU) and a good consistency between plates of the same nominal breast density equivalence (± 1.5 HU). In addition, dual energy CT provided mono-energetic HU from which mono-energetic linear attenuation coefficients of water and glandular and adipose equivalent materials were computed. The values for these coefficients were found in good agreement with results from literature, respectively direct mono-energetic measurements of breast samples, and computation by combining published breast tissue atomic compositions and linear attenuation coefficient tables. In conclusion, CT was found effective for the verification of the breast equivalent material, and the homogeneity and consistency of the plates were found satisfactory. Furthermore, the most recent spectral CT technology allowed demonstrating a good agreement of the attenuation properties of breastequivalent material plates with state-of-the-art knowledge of real breast tissue attenuation.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
N. Geeraert, R. Klausz, P. Giudici, S. Muller, L. Cockmartin, and H. Bosmans "Dual energy CT-based characterization of x-ray attenuation properties of breast equivalent material plates", Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83134V (3 March 2012); https://doi.org/10.1117/12.911334
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Breast

Signal attenuation

Tissues

Dual energy imaging

Breast cancer

Calibration

X-ray characterization

Back to Top