19 March 2014 Towards in-vivo K-edge imaging using a new semi-analytical calibration method
Carsten Schirra, Axel Thran, Heiner Daerr, Ewald Roessl, Roland Proksa
Author Affiliations +
Abstract
Flat field calibration methods are commonly used in computed tomography (CT) to correct for system imperfections. Unfortunately, they cannot be applied in energy-resolving CT when using bow-tie filters owing to spectral distortions imprinted by the filter. This work presents a novel semi-analytical calibration method for photon-counting spectral CT systems, which is applicable with a bow-tie filter in place and efficiently compensates pile-up effects at fourfold increased photon flux compared to a previously published method without degradation of image quality. The achieved reduction of the scan time enabled the first K-edge imaging in-vivo. The method employs a calibration measurement with a set of flat sheets of only a single absorber material and utilizes an analytical model to predict the expected photon counts, taking into account factors such as x-ray spectrum and detector response. From the ratios of the measured x-ray intensities and the corresponding simulated photon counts, a look-up table is generated. By use of this look-up table, measured photon-counts can be corrected yielding data in line with the analytical model. The corrected data show low pixel-to-pixel variations and pile-up effects are mitigated. Consequently, operations like material decomposition based on the same analytical model yield accurate results. The method was validated on a experimental spectral CT system equipped with a bow-tie filter in a phantom experiment and an in-vivo animal study. The level of artifacts in the resulting images is considerably lower than in images generated with a previously published method. First in-vivo K-edge images of a rabbit selectively depict vessel occlusion by an ytterbium-based thermoresponsive polymer.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Carsten Schirra, Axel Thran, Heiner Daerr, Ewald Roessl, and Roland Proksa "Towards in-vivo K-edge imaging using a new semi-analytical calibration method", Proc. SPIE 9033, Medical Imaging 2014: Physics of Medical Imaging, 90330N (19 March 2014); https://doi.org/10.1117/12.2043539
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Sensors

Data modeling

In vivo imaging

Data acquisition

X-rays

Optical filters

Back to Top