1.IntroductionIn the last few years, there has been increasing research interest in polarized light propagation in biological tissues. Most tissues are fibrous. Characterization of such structurally anisotropic turbid media has been the subject of some recent works using Monte Carlo simulation.1–4 In those studies, Mueller matrix served as a powerful tool to obtain pathological information on biological samples5–8 and evaluate the validity of tissue models and simulations. Antonelli et al.2 proposed a Monte Carlo model including large and small spherical scatterers in a single layer above the Lambertian substrate to explain the experimental backscattering Mueller matrix images of colon tissues. Wood et al.4 presented a Monte Carlo model for birefringent, optically active, multiply scattering media to describe the propagation of polarized light in biological tissues. Wang and Wang9 proposed a sphere birefringence model (SBM) which contains spherical particles randomly suspended in linearly birefringent media. The scattering property of the medium is isotropic, and birefringence is the only source of anisotropy. Recently, we proposed a sphere–cylinder scattering model (SCSM) to characterize the anisotropic scattering property of fibrous tissues such as bulk skeletal muscles.10,11 In that model, the anisotropy of the fibrous tissues is entirely attributed to the scattering of cylindrical scatterers. However, for complicated tissues, both cylindrical scatterers and the birefringence effect may coexist and contribute to anisotropic phenomena. In this paper, we present a new model containing both contributions and confirm its validity by comparing the simulations with experimental results. We start from SCSM and construct the sphere–cylinder birefringence model (SCBM) by adding a birefringent medium around the spherical and cylindrical scatterers. The Monte Carlo program for SCSM12 is also modified for SCBM. We use the new program to simulate the backscattering Mueller matrix patterns of a sphere–cylinder birefringence medium and analyze the influence of birefringence on the patterns. Comparisons to the experimental backscattering Mueller matrix patterns of skeletal muscle show that SCBM results in better agreement than SCSM and SBM, which verifies the assumption on the two sources of tissue anisotropy and demonstrates that SCBM is a more general model to characterize fibrous tissues such as skeletal muscle. 2.Method: Monte Carlo Simulation2.1.SCBM for Anisotropic MediaAs shown in Fig. 1, SCBM approximates the anisotropic turbid medium to a mixture of solid spherical and infinitely long cylindrical scatterers embedded in a linearly birefringent medium. In this work, we assume that the surrounding medium is a uniaxial material with its extraordinary axis being along the direction of the cylinders.9 Parameters for the scatterers are the same as those for the SCSM.11 They include number densities and sizes of both the spheres and cylinders, and the mean value and standard deviation of the angular distribution for the cylinders. Parameters for the surrounding medium include the value and axis direction of birefringence. Both the cylindrical orientation and the axis direction of birefringence can be adjusted in the three-dimensional (3-D) space. SCBM reduces to SCSM if the birefringence is set to zero, or to SBM if the scattering coefficient of the cylinders is set to zero. 2.2.Monte Carlo AlgorithmThe Monte Carlo program for SCBM was developed based on the polarization-sensitive SCSM program,12 which tracks the trajectory and polarization state of photons. In the SCSM program, after each scattering event, the photon moves along a new direction determined by the Mie theory13,14 and may lose part of its energy because of the absorption. A statistical method was designed to determine whether the photon is scattered by the cylinders or the spherical particles. The simulation process continues until the photon is completely absorbed or moves out of detection range. For SCBM, as the polarized photons transmit in the anisotropic medium, they alternately experience the transmission process in the birefringent medium and the scattering process by the spherical or infinitely long cylindrical scatterers. The Monte Carlo program for SCBM was also developed based on the polarization-sensitive SCSM program12 and the SBM program,9 which describes the detailed algorithm of the birefringence module. In SCBM, we assumed that the birefringence effect is the property of the surrounding medium and does not affect the scattering phase function, but the birefringence does alter the polarization states of the photons as they propagate between two successive scattering events.9,15 We added a new module to the SCSM Monte Carlo program to calculate the effects of birefringence. In SCSM, the polarization states of the photons are altered by scattering only. If the medium around the scatterers is birefringent, a scattered photon undergoes retardation between successive scatterings. The new module calculates the changes of Stokes vector due to the birefringent medium: where is the Mueller matrix of the standard retarder and is the rotational matrix. can be expressed by where is the retardation, which can be obtained by where is the transport path length between two successive scattering events, is the average refractive index, is the wavelength of light, and is the difference in refractive indices expressed by where is the angle between the propagation direction of the photon () and the extraordinary axis (). The birefringence value is defined by , where and are the refractive indices along the extraordinary and ordinary axes, respectively. can be expressed by where is the rotational angle expressed as where is the projection of the ordinary axis onto the Stokes plane.2.3.Validity Test: Comparison with SBMThe SCBM becomes SBM if the scattering coefficient of cylinders is set to zero. To test the validity of the new module, we set the scattering coefficient of the cylinders to zero in the SCBM program and compared the simulated Mueller matrix patterns with previously published results of SBM.16 Figure 2 shows the simulation results of both models using the same set of parameters for the spheres and birefringent medium.16 For the spheres, the diameter is 0.46 μm and the scattering coefficient is . The average refractive index of the birefringent surrounding medium is 1.34, and its extraordinary axis is along the horizontal axis. The maximum retardation at the transport length distance is calculated by .16 In Fig. 2(a)–2(d), the birefringence value takes 0, , , and , corresponding to , 0.1, 0.5, and 3, respectively. Figure 2 shows a good agreement between the simulation results of SCBM and SBM. 2.4.Validity Test: Comparison with Mueller Matrix Experiments2.4.1.Experiment setupFigure 3 shows a typical experimental setup for backscattering Mueller matrix measurement.10 A polarized He-Ne laser () is used as the light source. A quarter-wave plate (QW1) and a linear polarizer P1 control the incident polarization. The incident light reaches the sample through a small hole at the center of the mirror (), which is tilted at 45 deg to the incident beam. The mirror directs the backscattered light from the sample toward the camera through a quarter-wave plate (QW2) and a linear polarizer (P2). The backscattered light is imaged by a 14-bit CCD camera (Canon APS-C). A laboratory reference frame is defined such that both the muscle fiber orientation and the vertical linear polarization direction are along the axis. In the experiments, six different polarization states were used for both incidence and detection: horizontal linear (), vertical linear (), 45-deg linear (), 135-deg linear (), right circular (), and left circular (). A total of 36 reflectance images were captured with different combinations of the six incidence and detection polarization states. The Mueller matrix was calculated from these images: For convenience, each reflectance image is indexed by two capital letters: the first letter represents the incidence polarization state and the second letter represents the detection polarization state. For example, HV represents a reflectance image of horizontally polarized () incidence and vertically polarized () detection.2.4.2.Model sample for SCBMIn our previous work,10 we demonstrated that a sample with polystyrene microspheres and well-aligned silk fibers immersed in water can be used as the model sample of SCSM. Meanwhile, other groups have reported of the model sample for SBM, which includes spherical scatterers embedded in a linearly birefringence medium.4 The SBM sample consisted of polystyrene microspheres immersed in a polymer hydrogel called polyacrylamide. During the experiments, the polyacrylamide sample was strained via extension to create birefringence along the direction of strain. In our sample developed for SCBM, scattering is produced through the addition of polystyrene microspheres and silk fibers before the polymerization of the polyacrylamide, and birefringence is produced through the straining of the polyacrylamide. The fabrication process of the polyacrylamide has been described in detail in the previous publication.4 In addition, the direction of both the strain (the extraordinary axis of birefringence) and direction of silk fibers, the scattering coefficient of spherical scatterers, and the birefringence value can be adjusted in our sample. In this paper, the sample is a three-layered medium consisting of a slab of well-aligned silk fibers along the axis and polystyrene microspheres submerged in the hydrogel. The first and third layers are 5-mm-thick hydrogel containing 0.2-μm-diameter polystyrene microspheres (International Laboratory). The refractive indices of the microspheres and polyacrylamide are 1.59 and 1.39, respectively.4 The scattering coefficients are determined by the concentration of the microspheres. The second layer contains only well-aligned silk fibers (provided by Guangxi Institute of Supervision and Testing on Product Quality). The thickness of the silk fiber slab is 1 mm, and the refractive index is 1.56. The diameter of the silk fiber, which contains a substructure, is taken as 1.5 μm, and the scattering coefficient of the silk layer is estimated as (Ref. 11). To discriminate the anisotropy due to the birefringence effect of the surrounding medium and the scattering by aligned cylinders, we aligned the silk fibers along the axis and the direction of strain (the extraordinary axis of birefringence) along the 45-deg angle axis on the plane. The polyacrylamide sample was strained with the extension of 5 mm (the maximum extension is 6 mm), and the difference in refractive indices was about (Ref. 4). 2.5.Results from the Experiment and SCBM SimulationsUsing the new program based on SCBM, we simulated the experimental results of the sample. All the parameters used in the simulation matched the experiments. As shown in Fig. 4, the simulated result using SCBM agrees well with the experimental result of the strained microsphere-silk polyacrylamide. Although Fig. 4(a) and 4(b) are still different quantitatively, the characteristic features in the two sets of Mueller matrix elements are very similar. The detailed analysis about the effect of birefringence on the backscattering Mueller matrix is given in the following section. 3.Discussion3.1.Comparison with the Simulations of SCSMThe characteristic features of the Mueller matrix of sphere scattering media have been reported previously by other groups.17,18 For the isotropic scattering media, the Mueller matrix has diagonal symmetry properties. The and elements are always blanks. The patterns of and are both circular. The element is quatrefoil, and its intensity distributions along the and axes are nearly the same. The element has a symmetric cross-like pattern with almost identical intensity distribution along the and axes. There are several pairs of elements of similar intensity patterns but different rotations. For example, can be obtained by rotating by 45 deg, and the same relation applies to the , , and pairs. In our previous paper,11 the Mueller matrix patterns of the sphere–cylinder scattering medium were described in detail. According to the Mie scattering theory for infinitely long cylinders,13,14 polarization-maintaining photons tend to be scattered in the direction perpendicular to the cylindrical scatterers (i.e., the axis in Fig. 4). Therefore the intensity distributions of all the Mueller matrix elements around the axis are higher than those around the axis. For example, has the typical rhombus profile with an elongation along the axis. and have similar shapes of quatrefoils, but the intensity along the axis is higher than that along the axis. The total intensity distributions of the and elements are weaker than those of the and elements. The element still shows a cross-like pattern, but the intensity along the axis is higher than that along the axis. The total intensity distribution and size of the element are weaker than those of the element. Compared to the sphere–cylinder scattering medium, the characteristic features of the Mueller matrix elements for the sphere–cylinder birefringence medium are very different. Monte Carlo–simulated backscattering Mueller matrix patterns of SCSM and SCBM are shown in Fig. 5. The Mueller matrix elements have been normalized to the element to compensate for the radial decay of intensity. The extraordinary axis of the birefringent medium is along the axis in the laboratory frame. For easier comparison, parameters of the scatterers are the same as those in Ref. 11: The diameters of spheres and cylinders are 0.2 and 1.5 μm, and their refractive indices are 1.59 and 1.56, respectively. The refractive index of the surrounding medium is 1.33. The cylinders are aligned in the plane, and their orientations fluctuate around the axis following a Gaussian distribution with a standard deviation of 10 deg half width. The scattering coefficients of spheres and cylinders are 10 and , respectively. In SCBM, since the birefringence value of tissues ranges from to (Ref. 19), we set to 0, , , and . Figure 5 shows the influence of linear birefringence on the spatial intensity distributions of the backscattering Mueller matrix elements. The detailed features are summarized as follows: (1) The has the same typical rhombus profile as that in SCSM. Linear birefringence does not affect the element, which relates only to unpolarized light intensity. (2) The and elements have the same shapes of quatrefoils, and the also has the same cross-like pattern, as those in the SCSM simulations. For the present configuration, where both the extraordinary axis and the cylindrical scatterers are along the vertical () direction, , , and are hardly affected by linear birefringence. This is because the Mueller matrix patterns represent mainly contributions from the polarization-maintaining photons. These elements relate only to the horizontal (0 deg) and vertical (90 deg) polarization components, which are either parallel or perpendicular to the extraordinary axis and subject to minimal effects due to the birefringent medium. (3) The intensity distributions of the , , , , , , and elements are sensitive to birefringence , since circular or 45-deg and 135-deg linear polarization states are affected by retardation due to birefringence. As increases, the , , , and patterns stay in the same shape but shrink in size. The shapes of the and patterns change to quatrefoils stretched along the axis. (4) The ), , and patterns have similar shapes to those of , , and , respectively, but the contrasts are different. The transformation between circular and linear polarization states in the turbid medium is enhanced by linear birefringence.9 3.2.Effects of the Value and Orientation of Birefringence on the Mueller Matrix PatternsIn Fig. 6, we compare the different responses of and to changes in the birefringence value while keeping both the extraordinary axis and the cylindrical scatterers along the axis in the laboratory frame. As the value of birefringence increases, the total intensity of remains almost the same, but the intensity decreases rapidly and approaches zero when exceeds . One may use to detect the presence of birefringence. As increases, the intensity of the , , , , and Mueller matrix elements quickly decrease to zero, and the terms related to 0-deg or 90-deg linear polarization (, ) remain almost the same. These phenomena are consistent with the simulation results of SBM (see Fig. 9 in Ref. 9), in which the degree of polarization (DOP) of diffusely reflected light does not change significantly with when the incident light is in horizontal (0 deg) or vertical (90 deg) polarization, but does decrease fast and approaches zero with increasing if the incident light is 45-deg linear polarization or circle polarization. The decrease of DOP means more recorded photons are depolarized and the Mueller matrix loses their features. The intensity of the , , , , , and elements will first increase then quickly decrease to zero as increases from zero. This is also consistent with the simulation results of SBM (see Fig. 4 in Ref. 16). In the above simulations, the extraordinary axis of birefringence has been set parallel to the orientation of the cylindrical scatterers, and to the axis of the laboratory frame. We may also assume that the two directions are different and simulate the Mueller matrix patterns for different orientation of the extraordinary axis. As shown in a previous work,11 the long axis of the pattern is always perpendicular to the direction of the fibers. For simplification, we set the direction of the cylindrical scatterers along the axis in the laboratory frame and the extraordinary axis of birefringence in the plane. All the patterns except for the display asymmetric behavior, as shown in Fig. 4(b). A further study indicates that is the most sensitive to the angle mismatch. As shown in Fig. 7, we changed the extraordinary axis from the axis to axis at intervals of 15 deg in the simulations while keeping the other parameters the same as in Fig. 5(c). The pattern has a cross-like shape when the extraordinary axis is parallel or perpendicular to the cylinders, but is distorted when neither the fast axis nor the slow axis of birefringence matches the fiber orientation. Therefore, the pattern may serve as an indicator for the mismatch between the directions of the birefringence axis and the fiber orientation. In real biological tissues, the birefringence axis may vary in the 3-D space. The corresponding features can also be simulated using the current SCBM program. 3.3.Comparison with Experimental Results on Skeletal MusclesIn a previous paper,10 we demonstrated that SCSM can be used to characterize the structural and optical properties of skeletal muscle. The Mueller matrix elements of both skeletal muscles and a model sample containing polystyrene microspheres and silk fibers show very similar features. However, more careful examinations reveal inconsistency between the experimentally obtained and the simulated results. For example, the third row and the third column of the simulated Mueller matrix using SCSM display clear patterns that are not apparent in the experimental results of skeletal muscle. Simulations using SCBM show that this discrepancy is due to the birefringence effect. In the present work, the skeletal muscle samples are fresh bovine sternomandibularis muscle excised from the animals 2 h after slaughtering. The Mueller matrix elements of the skeletal muscle were compared with the simulations using SCBM, SCSM, and SBM as shown in Fig. 8. The following parameters are used in the SCBM. The extraordinary axis of the birefringent surrounding medium and the direction of the muscle fibers are both along the axis. The birefringence value is (Ref. 20). The diameters of the spheres and infinitely long cylinders are 0.2 and 1.5 μm, respectively, and the refractive indices of scatterers are both 1.4. The average refractive index of the surrounding medium is taken as 1.33. The standard deviation of angular distribution of the cylinders is 10 deg. Using the previous published results10 as a reference, the ratio of the scattering coefficients of spheres and cylinders is set at to give the best match between the shapes of the experimental and simulated images. The total scattering coefficients along the axis is , which is close to the scattering coefficient of the skeletal muscle.10 In the SCSM, the birefringence value is set to zero, and in the SBM, the scattering coefficient of cylinders is set to zero. The other parameters are the same as those in the SCBM. Compared with the experiments, simulations of the three anisotropic models (SCBM, SCSM, and SBM) had respective similarities and differences. The characteristic features in the Mueller matrix patterns of anisotropic turbid media showed contributions by both optical anisotropy due to birefringence and scattering anisotropy due to cylindrical scatterers. As shown in Fig. 8, for the Mueller matrix elements of a muscle sample, has the typical rhombus shape, and has a cross-like pattern with the dominant distribution along the axis. The simulations using SCBM and SCSM regenerated similar features in these two elements. However, simulations using SBM resulted in totally different shapes. The pattern is centrosymmetric and has a symmetric cross-like pattern with identical intensity distributions along the and axes. Thus one has to include cylindrical scatterers in the model to regenerate these characteristic features in and of anisotropic tissues. These features of , , , and are due to the anisotropy of the cylinders, since the polarization-maintaining photons tend to be scattered to the direction perpendicular to the cylindrical scatterers (the axis).11 On the other hand, the third and fourth rows and columns of the experimentally obtained Mueller matrix for the muscle samples show only weak patterns. Simulations using both SCBM and SBM regenerated such features, but simulations using SCSM resulted in much clearer patterns, for example clear quatrefoils for the and elements. More detailed simulations using SCBM showed that the birefringence effect is responsible for smoothing out the distinctive features in the third and fourth rows and columns of the Mueller matrix elements. The above analysis proves that simulations using SCBM result in better agreements with the experiments than SCSM and SBM. It should be pointed out that the Mueller matrix elements related to the third and fourth rows and columns do not show good agreements between the skeletal muscle experiments [Fig. 8(a) and also Ref. 7] and the SCBM simulations [Fig. 8(b)]. Simulation shows that these elements are all weak and noisy when birefringence exists, as shown in Fig. 8(b) and 8(d). The corresponding experimental patterns also display noisy and irregular patterns,7 which may also contain measurement errors and inhomogeneity effects of the tissue sample. One has to consider contributions from both the cylindrical scatterers and the birefringence effect to explain the characteristic features of polarized photons scattering in complicated anisotropic turbid media such as skeletal muscles. These two terms on tissue anisotropy are perhaps corresponding to the anisotropy of form defined by the tissue microstructure and the anisotropy of material controlled by intrinsic anisotropic character of metabolic molecules.20 In addition, all the experimentally obtained elements showed cross-like patterns without distortion. From the above analysis in Sec. 3.2, we conclude that the extraordinary axis of the birefringent media is parallel to the direction of the fibrous structures in all the samples we have measured, including the skeletal muscles. This may be a hint that the two come from the same origin. 4.ConclusionBased on the sphere–cylinder scattering model (SCSM), a sphere–cylinder birefringence model (SCBM) was developed by adding birefringence to the medium surrounding the scatterers. The Monte Carlo program for SCSM was also revised for SCBM to take into account the birefringence effects. The characteristics due to birefringence were examined by comparisons between the simulated backscattering Mueller matrix patterns using both SCSM and SCBM. It was found that the third and fourth rows and columns of the Mueller matrix elements no longer had distinctive patterns when the birefringence exceeded a certain value. These matrix elements may serve as good indicators of strong birefringence. If the extraordinary axis is not parallel to the orientation of the cylinders and the axis, all the Mueller matrix elements except will be distorted. These matrix elements can be used to detect the mismatch between the extraordinary axis and the orientation of the fibrous structure. Finally we compared the experimental results of a skeletal muscle sample with the simulations using the different tissue models, i.e., SCBM, SCSM, SBM, and the simulations from the SCBM can reveal the characteristic features of the Mueller matrix patterns of anisotropic tissues such as muscles better than those from SCSM and SBM. The good agreement between the experiments and the simulations using SCBM confirms that for fibrous biological tissues, both optical anisotropy, such as birefringence, and scattering anisotropy contribute to the anisotropy of fibrous tissues. The experimental results also prove that the extraordinary axis of anisotropy and the orientation of fibrous structure are always in parallel for the muscles, which may hint that the two are interrelated. AcknowledgmentsThis work has been supported by National Natural Science Foundation of China (NSFC) grants 10974114, 11174178, and 41106034 and Open Fund of Key Laboratory of Optoelectronic Information and Sensing Technologies of Guangdong Higher Education Institutes, Jinan University. ReferencesM. R. Antonelliet al.,
“Mueller matrix imaging of human colon tissue for cancer diagnostics: how Monte Carlo modeling can help in the interpretation of experimental data,”
Opt. Express, 18
(10), 10200
–10208
(2010). http://dx.doi.org/10.1364/OE.18.010200 OPEXFF 1094-4087 Google Scholar
M. R. Antonelliet al.,
“Impact of model parameters on Monte Carlo simulations of backscattering Mueller matrix images of colon tissue,”
Biomed. Opt. Express, 2
(7), 1836
–1851
(2011). http://dx.doi.org/10.1364/BOE.2.001836 BOEICL 2156-7085 Google Scholar
Y. Denget al.,
“Numerical study of the effects of scatterer sizes and distributions on multiple backscattered intensity patterns of polarized light,”
Opt. Lett., 33
(1), 77
–79
(2008). http://dx.doi.org/10.1364/OL.33.000077 OPLEDP 0146-9592 Google Scholar
M. F. G. WoodX. GuoI. A. Vitkin,
“Polarized light propagation in multiply scattering media exhibiting both linear birefringence and optical activity: Monte Carlo model and experimental methodology,”
J. Biomed. Opt., 12
(1), 014029
(2007). http://dx.doi.org/10.1117/1.2434980 JBOPFO 1083-3668 Google Scholar
M. H. Smithet al.,
“Mueller matrix imaging polarimetry in dermatology,”
Proc. SPIE, 3911 210
–216
(2000). http://dx.doi.org/10.1117/12.384904 PSISDG 0277-786X Google Scholar
J. M. BuenoM. C. W. Campbell,
“Confocal scanning laser ophthalmoscopy improvement by use of Mueller-matrix polarimetry,”
Opt. Lett., 27
(10), 830
–832
(2002). http://dx.doi.org/10.1364/OL.27.000830 OPLEDP 0146-9592 Google Scholar
X. LiJ. C. RanasinghesagaraG. Yao,
“Polarization-sensitive reflectance imaging in skeletal muscle,”
Opt. Express, 16
(13), 9927
–9935
(2008). http://dx.doi.org/10.1364/OE.16.009927 OPEXFF 1094-4087 Google Scholar
A. Pierangeloet al.,
“Ex-vivo characterization of human colon cancer by mueller polarimetric imaging,”
Opt. Express, 19
(2), 1582
–1593
(2011). http://dx.doi.org/10.1364/OE.19.001582 OPEXFF 1094-4087 Google Scholar
X. WangL. V. Wang,
“Propagation of polarized light in birefringent turbid media: a Monte Carlo study,”
J. Biomed. Opt., 7
(3), 279
–290
(2002). http://dx.doi.org/10.1117/1.1483315 JBOPFO 1083-3668 Google Scholar
H. Heet al.,
“Application of sphere–cylinder scattering model to skeletal muscle,”
Opt. Express, 18
(14), 15104
–15112
(2010). http://dx.doi.org/10.1364/OE.18.015104 OPEXFF 1094-4087 Google Scholar
H. Heet al.,
“Two dimensional backscattering Mueller matrix of sphere–cylinder scattering medium,”
Opt. Lett., 35
(14), 2323
–2325
(2010). http://dx.doi.org/10.1364/OL.35.002323 OPLEDP 0146-9592 Google Scholar
T. Yunet al.,
“Monte Carlo simulation of polarized photon scattering in anisotropic media,”
Opt. Express, 17
(19), 16590
–16602
(2009). http://dx.doi.org/10.1364/OE.17.016590 OPEXFF 1094-4087 Google Scholar
C. F. BohrenD. R. Huffman,
“Absorption and scattering of light by small particles,”
Absorption and Scattering by a SphereA Potpourri of Particles, 83194
–113208 John Wiley and Sons, New York
(1983). Google Scholar
A. KienleF. ForsterR. Hibst,
“Anisotropy of light propagation in biological tissue,”
Opt. Lett., 29
(22), 2617
–2619
(2004). http://dx.doi.org/10.1364/OL.29.002617 OPLEDP 0146-9592 Google Scholar
M. ŠormazT. StammP. Jenny,
“Influence of linear birefringence in the computation of scattering phase functions,”
J. Biomed. Opt., 15
(5),
–055010
(2010). http://dx.doi.org/10.1117/1.3503475 JBOPFO 1083-3668 Google Scholar
C. Baravianet al.,
“Birefringence determination in turbid media,”
Phys. Rev. E, 75
(3), 032501
(2007). http://dx.doi.org/10.1103/PhysRevE.75.032501 PLEEE8 1063-651X Google Scholar
A. Hielscheret al.,
“Diffuse backscattering Mueller matrices of highly scattering media,”
Opt. Express, 1
(13), 441
–453
(1997). http://dx.doi.org/10.1364/OE.1.000441 OPEXFF 1094-4087 Google Scholar
Y. Denget al.,
“Characterization of backscattering Mueller matrix patterns of highly scattering media with triple scattering assumption,”
Opt. Express, 15
(15), 9672
–9680
(2007). http://dx.doi.org/10.1364/OE.15.009672 OPEXFF 1094-4087 Google Scholar
J. J. Pasquesiet al.,
“In vivo detection of exercised-induced ultrastructural changes in genetically-altered murine skeletal muscle using polarization-sensitive optical coherence tomography,”
Opt. Express, 14
(4), 1547
–1556
(2006). http://dx.doi.org/10.1364/OE.14.001547 OPEXFF 1094-4087 Google Scholar
V. V. TuchinL. V. WangD. A. Zimnyakov,
“Tissue structure and optical models,”
Optical Polarization in Biomedical Applications, 7
–28 Springer, New York
(2006). Google Scholar
|