1.IntroductionIn recent years, surface plasmon resonance (SPR) has been widely explored for various sensing applications.1–3 Among all SPR technologies, localized SPR (LSPR) of metal nanoparticles (NPs) has attracted much attention.4–8 Similar to SPR, LSPR is the collective electron oscillations of metal NPs when the incident photon frequency conforms to the oscillation frequency of conductive electrons, but its frequency can be tuned by changing the size, geometry, material, and surrounding dielectrics of the NPs. Currently, most fiber-optic SPR sensors are designed for single-channel detection,9–11 which cannot detect more than one analyte or eliminate the adverse effect caused by the changes in the refractive index (RI) of the bulk solution. Seldom do sensors have multiple sensing areas fabricated on a short section of optical fiber, which can realize multichannel detection and self-compensation.12 Various approaches have been developed for obtaining two sensing channels on a single optical fiber.13,14 For example, a dual-channel SPR probe is formed by coating a polymer layer on gold film to tune the SPR resonance wavelength approximately 100 nm.15 It uses wavelength interrogation for multiple wavelengths but cannot detect changes in the RI of the bulk solution induced by the presence or absence of biochemical molecules. A two-cascaded LSPR fiber sensor based on intensity interrogation has been demonstrated to simultaneously detect two analytes.16 However, intensity interrogation is susceptible to stability of the light source, and its fabrication process is relatively complex. Other SPR sensors based on fiber-optic bundles17 to realize multichannel detection limit the miniaturization of the sensing element, and the procedure is complex. Rapid and parallel detection in a single chip based on prism-configuration SPR and LSPR spectroscopy have been realized previously, but they always depend on complex and expensive components, which are not appropriate in practice for structure miniaturization.18–20 In this paper, we proposed a dual-channel fiber-optic sensing probe based on two sensing structures with different modulation methods (intensity and wavelength interrogation). Two unclad portions of the fiber probe are coated with gold nanoparticles (GNPs) and a sandwich configuration of Au/indium tin oxide (ITO)/Au film, respectively. By depositing a thin high-index ITO dielectric layer into the gold-sensing surface, the SPR resonance wavelength can be modulated. We can tune the transmission intensity of the intensity interrogation-based channel (Au NP channel) and resonance wavelength of the wavelength interrogation-based channel (Au/ITO/Au film channel) by modifying the surrounding RI, which creates a dual-channel hybrid intensity–wavelength-modulated SPR sensor probe. The assay time for a kind of biomolecular sample detection is less than 20 min, and it can broaden the SPR detection range of a sensor from visible to near infrared. Furthermore, the performance of the sensor is comparable with traditional SPR sensors.21,22 2.Materials and MethodsAs depicted in Fig. 1(a), light from a halogen lamp (HL-2000-FHSA, Ocean Optics, Inc.) was launched into one end of the probe. The transmission spectrum was collected by a spectrometer (HR4000, Ocean Optics, Inc.) and demodulated by a computer. We used a home-built flow cell to control the sample solution insertion and ejection. For comparison, a flow rate controlled by a peristaltic pump was selected for injecting the analytes. Figure 1(b) illustrates the schematic diagram of the two channels of the probe. The fiber probes were prepared using multimode plastic-clad silica-optical fiber (0.37 NA, core, and cladding diameter). The two end faces of probe were polished to decrease connection loss between the probe and fiber jumper. The two unclad core sections of optical fiber were cleaned with deionized water and acetone and dried with a pure gas stream. Then, the two sections were coated with 40-nm gold particles and a 35-nm 35-nm Au/10-nm ITO/15-nm Au layer, respectively. They were labeled as Channel 1 and Channel 2. In Channel 1, the self-synthesized spherical gold NPs23 were immobilized on the core of the fiber by utilizing the layer-by-layer method. The specific preparation process of Channel 1 was as follows: the core of optical fiber was first immersed in Piranha solution (a mixture consisting of seven volumes of concentrated and three volumes of 30% ) for 45 min, followed by thorough flushing with deionized water, and dried with a pure gas stream; then, a trilayer polyelectrolyte (PE) structure was selected for self-assembly of GNPs. The channel was sequentially dipped in poly(diallyldimethylammonium chloride) (strong cationic PE), poly(sodium--styrenesulfonate) (the anionic PE), and poly(allylamine hydrochloride) (PAH, weak cationic PE). The soak time for etch PE was 15 min. Finally, the GNPs stabilized by citrate were immobilized on the outermost PAH layer for 120 min to form a self-assembled monolayer. In our test, the NP self-assembled monolayer was extremely stable during the six repeated binding and regeneration conditions. In Channel 2, the Au/ITO/Au film was coated on the cleaned unclad core using the Turbo Sputter Coater (K575XD from E. M. Technologies Ltd. Ashford, Kent). 3.Results and DiscussionThe response characteristics of the RI of the dual-channel fiber-optic sensor were experimentally investigated. Figure 2(a) presents the transmission spectra of the proposed biosensor versus RIs. As the surrounding RI increases gradually, the transmission intensity of the dip A corresponding to Channel 1 decreases significantly and the dip wavelength has negligible shifts. Additionally, the wavelengths of dip B corresponding to Channel 2 increase while the surrounding RI increases from 1.3266 to 1.3683. The normalized intensity changes of Channel 1 and the wavelength shifts of Channel 2 both have a linear response to the bulk RI between 1.3266 and 1.3683, which is consistent with the range for the most common biofluids, as shown in Figs. 2(b) and 2(c). The corresponding RI sensitivities are 334.1% and for the GNPs and the Au/ITO/Au film channels, respectively. Here, RI sensitivity is defined as the change of resonant wavelength () and resonant intensity () with respect to the bulk RI changes. The resolution of the RI measurement is estimated to be and , respectively, which is defined as , where is the standard deviation of noise and is the RI sensitivity. can be calculated from the time response of the resonant dip for the fixed RI of the bulk solution. To further understand the operating principle of the dual-channel SPR sensor, Fig. 3 shows the distribution of the spatial electric field of different resonance positions caused by different resonance modes. The black dotted lines in Figs. 3(c) and 3(e) represent the boundary of the Au/ITO/Au composite and Au films, respectively. As depicted in Figs. 3(a), 3(c), and 3(e), the electric field is mostly confined and the maximum field distribution is exhibited on the surface of the NPs or metal film. Figures 3(b), 3(d), and 3(f) illustrate the transmission spectra of LSPR and SPR modes, respectively. It can be seen that the LSPR resonance dip caused by GNP absorption appears in the range of 500 to 600 nm. Simultaneously, there is an obvious dip located at the range of 600 to 1000 nm, induced by the Au/ITO/Au film channel. As shown in Figs. 3(c) and 3(e), compared with the pure gold layer SPR structure, the composited Au/ITO/Au layer structure with the same thickness shows a stronger near-field intensity enhancement (the field intensity maximum on the surface of the composited Au/ITO/Au layer structure is 3.8, whereas that of the Au layer is 3.3), which is beneficial to improve the interaction between the evanescent field and biomolecules and achieve high-precision detection. Furthermore, to avoid crosstalk between the channels (the resonance wavelengths of the different channels are located at different spectral positions), the SPR wavelengths of the channels should be able to tune over a wide range to completely separate the two channels. There are several approaches to realize the change of the operation wavelength of the SPR sensor,24,25 and some of them are too complex. In order to simplify the fabrication, a thin layer of ITO was selected to deposit between gold layers to form the sandwich configuration. As a high-RI material, the ITO coating is one of the ideal candidates to tune the operating wavelength of the SPR sensor. Fig. 3(d) shows that the SPR resonance wavelength shifts toward the longer wavelength when we use the Au/ITO/Au sandwich configuration. To further investigate the multianalyte sensing feasibility of the dual modulation (intensity and wavelength interrogation) of the dual-channel sensor, we carried out model experiments in a buffer solution to kinetically monitor the molecular recognition events. Anti-rabbit immunoglobulin G (anti-IgG) was functionalized on the GNP channel as the molecular recognition probe to specific binding with IgG, and ribonuclease B (RNase B) was fixed on the Au/ITO/Au film channel as the recognition part to specific binding with Con A. The immobilizing processes of IgG and Con A are depicted in Fig. 4. We immersed two channels in 11-mercaptoundecanoic acid () at room temperature for 12 h to self-assemble an alkanethiol monolayer on the surfaces; then the probe was immersed in an aqueous solution containing 1-ethyl-3-(3-dimethylamino-propyl) carbodiimide hydrochloride () and -hydroxysuccinimide () for 30 min at 4°C to activate the carboxyl of the alkanethiol layer. After activating, the probe was rinsed with deionized water and dried under nitrogen. Channel 1 was immersed in anti-rabbit IgG solution [ in 0.01 M phosphate-buffered saline buffer (PBS buffer, )], and Channel 2 was immersed in RNase B solution ( in 0.01 M PBS buffer, ) for 30 min to form a stable monomolecular layer, respectively. After rinsing with PBS buffer, bovine serum albumin was used to deactivate the unreacted groups on the double-channel surfaces. Finally, the functional probe was obtained and could be used for the measurement of specific biomolecular binding. The biological monitoring performance of this dual-channel fiber biosensor was evaluated based on the specific binding of IgG to anti-IgG and Con A to RNase B. IgG and Con A samples with different concentrations were prepared in a PBS buffer (). Before the samples were injected into the flow cell, the PBS buffer was introduced to establish the baseline value. The real-time response of the two channels was monitored by LabVIEW, and the experimental data were processed every 2 s. The time response of the specific biomolecular binding of the two channels is shown in Fig. 5. As a comparison, we also gave the signal changes of nonspecific binding in the other channels during IgG and Con A detection in Figs. 5(a) and 5(b). It is worth pointing out that the real-time response of nonspecific binding was almost the same for detecting molecules with different concentrations. Therefore, only one comparison curve is shown in Figs. 5(a) and 5(b). The molecular binding will cause the increase of localized RI on the NP surface. Thus, the intensity of 560-nm incident light reduced with the increase of time, then reached a steady state after 1200 s. Figure 5(a) shows that the intensity of Channel 1 decreased due to the injection of IgG, which was consistent with the fact that IgG bound specifically to anti-IgG on the sensing region surface. Using urea solution (8.0 M) to regenerate the biosensor surfaces, IgG samples with various concentrations ranging from 0.05 to (0.05, 0.1, 0.2, and ) were evaluated. The response increased with the increase of IgG concentration. However, the resonance wavelength of Channel 2 remains unchanged, which means no molecular interaction occurred in Channel 2 during IgG detection. Moreover, the response of Channel 2 also demonstrates there was no significant bulk RI change as the IgG concentration increased. Figure 5(c) shows the relationship between the intensity of Channel 1 and different concentrations of IgG samples. The normalized intensity decreased linearly with the concentration of the samples. Error bars in Fig. 5 give the variance of three repeated experiments. Subsequently, the real-time responses of the designed biosensor to Con A with different concentrations (0.05, 0.08, 0.1, 0.3, and ) were experimentally investigated. As shown in Fig. 5(b), the resonance wavelength of Channel 2 had a red-shift due to the bonding between Con A and RNase B. Likewise, the unchanged intensity of Channel 1 can also indicate there was no significant bulk RI change during the Con A detection process. The relationship between different concentrations of Con A samples and wavelength response of Channel 2 is shown in Fig. 5(d). The resonance wavelength moved toward longer wavelengths linearly as Con A concentration increased. The experiment of introducing a buffered mixture containing both IgG and Con A was also performed. The results showed similar intensity and wavelength responses as Figs. 5(a) and 5(b), except that the signal change occurred almost at the same time. Through the utilization of a reference channel, we can ensure that the measured signal change was caused by the specific binding event between analyte and corresponding recognition molecules on the sensing surface. The limits of detection were 0.05 and for the two channels, respectively. 4.ConclusionIn summary, we proposed and demonstrated a dual-channel fiber-optic biosensor using a hybrid interrogation of intensity and wavelength modulation. The intensity and wavelength modulation were generated from the SPR of GNPs and a sandwich configuration of Au/ITO/Au film, respectively. We fabricated dual-channel prototypes with a combination of GNPs and the sandwich configuration of Au/ITO/Au film. The sensing technology is completed by measuring the intensity variation and wavelength shift of the resonance dips in the transmission spectrum. In the RI range from 1.3266 to 1.3683, the corresponding sensitivities are and for the GNPs and the Au/ITO/Au film channels, respectively. We investigated the multianalyte sensing feasibility of this structure when the sensor probes are functionalized by different biological molecules and the dual channels can detect different biochemical targets simultaneously. The biochemical response demonstrates that this sensor can be used for dual-channel measurement and improve the detection efficiency. Future works will be focused on sensitivity and resolution enhancement by optimizing sensor structure and materials. AcknowledgmentsThe authors would like to thank the National Natural Science Foundation of China (61137005 and 11474043) for financial support. ReferencesA. K. Sharma et al.,
“Theoretical understanding of an alternating dielectric multilayer-based fiber optic SPR sensor and its application to gas sensing,”
New J. Phys., 10
(2), 023039
(2008). http://dx.doi.org/10.1088/1367-2630/10/2/023039 NJOPFM 1367-2630 Google Scholar
S. Franzen et al.,
“Plasmonic phenomena in indium tin oxide and ITO-Au hybrid films,”
Opt. Lett., 34
(18), 2867
–2869
(2009). http://dx.doi.org/10.1364/OL.34.002867 OPLEDP 0146-9592 Google Scholar
R. Verma et al.,
“Detection of heavy metal ions in contaminated water by surface plasmon resonance based optical fiber sensor using conducting polymer and chitosan,”
Food Chem., 166 568
–575
(2015). http://dx.doi.org/10.1016/j.foodchem.2014.06.045 Google Scholar
Z. Q. Tou et al.,
“Fiber optic refractometer based on cladding excitation of localized surface plasmon resonance,”
IEEE Photonics Technol. Lett., 25
(6), 556
–559
(2013). http://dx.doi.org/10.1109/LPT.2013.2245117 IPTLEL 1041-1135 Google Scholar
H. Y. Lin et al.,
“Tapered optical fiber sensor based on localized surface plasmon resonance,”
Opt. Express, 20
(19), 21693
–21701
(2012). http://dx.doi.org/10.1364/OE.20.021693 OPEXFF 1094-4087 Google Scholar
J. Cao et al.,
“Gold nanorod-based localized surface plasmon resonance biosensors: a review,”
Sens. Actuators, B, 195 332
–351
(2014). http://dx.doi.org/10.1016/j.snb.2014.01.056 Google Scholar
Y. B. Lin et al.,
“A reflection-based localized surface plasmon resonance fiber-optic probe for biochemical sensing,”
Biomed. Opt. Express, 2
(3), 478
–484
(2011). http://dx.doi.org/10.1364/BOE.2.000478 BOEICL 2156-7085 Google Scholar
S. Szunerits et al.,
“Sensing using localised surface plasmon resonance sensors,”
Chem. Commun., 48
(72), 8999
–9010
(2012). http://dx.doi.org/10.1039/c2cc33266c Google Scholar
J. H. Ahn et al.,
“Fiber-optic waveguide coupled surface plasmon resonance sensor,”
Opt. Express, 20
(19), 21729
–21738
(2012). http://dx.doi.org/10.1364/OE.20.021729 OPEXFF 1094-4087 Google Scholar
C. Perrotton et al.,
“Fiber optic surface plasmon resonance sensor based on wavelength modulation for hydrogen sensing,”
Opt. Express, 19
(106), A1175
–A1183
(2011). http://dx.doi.org/10.1364/OE.19.0A1175 OPEXFF 1094-4087 Google Scholar
N. Raoufi et al.,
“Fiber optic pH sensor using optimized layer-by-layer coating approach,”
IEEE Sens. J., 14
(1), 47
–54
(2014). http://dx.doi.org/10.1109/JSEN.2013.2280283 ISJEAZ 1530-437X Google Scholar
R. Verma et al.,
“A novel approach for simultaneous sensing of urea and glucose by SPR based optical fiber multianalyte sensor,”
Analyst, 139
(6), 1449
–1455
(2014). http://dx.doi.org/10.1039/c3an01983g ANLYAG 0365-4885 Google Scholar
L. X. Li et al.,
“Dual-channel fiber-optic biosensor for self-compensated refractive index measurement,”
IEEE Photonics Technol. Lett., 28
(19), 2110
–2113
(2016). http://dx.doi.org/10.1109/LPT.2016.2574337 IPTLEL 1041-1135 Google Scholar
Y. Liu et al.,
“Investigation of a capillary-based surface plasmon resonance sensor for biosensing,”
J. Lightwave Technol., 34
(17), 4036
–4042
(2016). http://dx.doi.org/10.1109/JLT.2016.2545691 JLTEDG 0733-8724 Google Scholar
W. Peng et al.,
“Investigation of dual-channel fiber-optic surface plasmon resonance sensing for biological applications,”
Opt. Lett., 30
(22), 2988
–2990
(2005). http://dx.doi.org/10.1364/OL.30.002988 OPLEDP 0146-9592 Google Scholar
H. Y. Lin et al.,
“Multiple resonance fiber-optic sensor with time division multiplexing for multianalyte detection,”
Opt. Lett., 37
(19), 3969
–3971
(2012). http://dx.doi.org/10.1364/OL.37.003969 OPLEDP 0146-9592 Google Scholar
Y. Liu et al.,
“Compact multi-channel surface plasmon resonance sensor for real-time multi-analyte biosensing,”
Opt. Express, 23
(16), 20540
–20548
(2015). http://dx.doi.org/10.1364/OE.23.020540 OPEXFF 1094-4087 Google Scholar
S. Mohseni et al.,
“Development of a label-free SPR sensor for detection of matrixmetalloproteinase-9 by antibody immobilization on carboxymethyldextran chip,”
Biosens. Bioelectron., 81 510
–516
(2016). http://dx.doi.org/10.1016/j.bios.2016.03.038 BBIOE4 0956-5663 Google Scholar
K. Tiwari et al.,
“Surface plasmon based sensor with order-of-magnitude higher sensitivity to electric field induced changes in dielectric environment at metal/nematic liquid-crystal interface,”
Sens. Actuators, A, 216 128
–135
(2014). http://dx.doi.org/10.1016/j.sna.2014.05.020 Google Scholar
K. Sathiyamoorthy,
“Modified two prism SPR sensor configurations to improve the sensitivity of measurement,”
Sens. Actuators, A, 191 73
–77
(2013). http://dx.doi.org/10.1016/j.sna.2012.11.029 Google Scholar
S. M. Chen et al.,
“Localized surface plasmon resonance-based micro-capillary biosensor,”
IEEE Photonics Technol. Lett., 28
(20), 2195
–2198
(2016). http://dx.doi.org/10.1109/LPT.2016.2582202 IPTLEL 1041-1135 Google Scholar
X. H. Zhao et al.,
“Optical fiber sensor based on surface plasmon resonance for rapid detection of avian influenza virus subtype H6: initial studies,”
J. Virol. Methods, 233 15
–22
(2016). http://dx.doi.org/10.1016/j.jviromet.2016.03.007 Google Scholar
S. F. Cheng et al.,
“Colloidal gold-modified optical fiber for chemical and biochemical sensing,”
Anal. Chem., 75
(1), 16
–21
(2003). http://dx.doi.org/10.1021/ac020310v ANCHAM 0003-2700 Google Scholar
L. L. Obando et al.,
“Tuning dynamic range and sensitivity of white-light, multimode, fiber-optic surface plasmon resonance sensors,”
Anal. Chem., 71
(22), 5116
–5122
(1999). http://dx.doi.org/10.1021/ac990470f ANCHAM 0003-2700 Google Scholar
D. Monzon-Hernandez et al.,
“Optical-fiber surface-plasmon resonance sensor with multiple resonance peaks,”
Appl. Opt., 43
(6), 1216
–1220
(2004). http://dx.doi.org/10.1364/AO.43.001216 APOPAI 0003-6935 Google Scholar
BiographyLixia Li received her BE degree in the School of Physics and Electronic Engineering from Zhengzhou University of Light Industry, Zhengzhou, China, in 2012. She is currently pursuing her PhD in optical engineering at Dalian University of Technology. Her research area is focused on fiber-optic sensors, surface plasmon resonance, and subwavelength optical design and fabrication. Xinpu Zhang received his PhD in optical engineering from the Department of Physics at Dalian University of Technology, Dalian, China, in 2016. He joined the School of Information Science and Technology at Southwest Jiaotong University as a lecturer. His research area is focused on optical fiber sensors, surface plasmon resonance, and fiber grating. Yuzhang Liang received his PhD in optical engineering from the Department of Physics at Dalian University of Technology, Dalian, China, in 2016. He is currently a postdoctor at Nanjing University. His current research interests include surface plasmon resonance and subwavelength optical design and fabrication. Jianye Guang received his BS degree in optical information science and technology from Dalian University of Technology, Dalian, China, in 2015. He is currently a postgraduate in optics engineering at the College of Physics and Optoelectronic Engineering, Dalian University of Technology. His current research interests include surface plasmon resonance and biochemical sensing. Wei Peng received her doctoral degree in optical engineering from Dalian University of Technology, Dalian, China, in 1999. After spending 4 years in the Center for Photonics Technology within the Department of Electrical Engineering at Virginia Polytechnic Institute and State University as a visiting scholar and postdoctor, she took a professor faculty position at Dalian University of Technology, China, in 2009. Currently, her research interests include fiber-optic sensors, surface plasmon resonance, and subwavelength optical design and fabrication. |