27 October 2018 Study on the influence of optical absorption on polarization characterization of tissues
Yunfei Wang, Yu Huang, Nan Zeng, Yihong Guo, Yonghong He, Hui Ma
Author Affiliations +
Abstract
Absorption effect is a basic optical phenomenon and an important feature in tissue imaging and characterization. Based on our Monte Carlo simulation on the anisotropic tissue model (sphere-cylinder birefringence model), combined with our experiments of tissue phantoms, we demonstrate the influence of absorption effect on Mueller matrix and particularly on depolarization, linear retardance, and diattenuation parameters. The simulation and experimental results show a good consistency on the suppressed depolarization and scatterering induced retardance, and the enhanced diattenuation caused by the absorption, and also indicate the birefringence induced retardance insensitive to the absorption. Study of the phase function of different incident polarized lights and the distribution of scattering number gives a preliminary explanation about the above results.

1.

Introduction

Light scattering and absorbing are two main processes of the interaction between light and biological tissues. Generally, the scattering in most of biological tissues can degrade the penetration depth and the image contrast using optical methods. Compared with other techniques, polarization imaging can suppress contributions from multiple scattered photons, and improve the imaging quality for superficial tissues. Moreover, multidimensional description-based Stokes vectors or Mueller matrices can expand the potential of tissue characterization.

Since Bickel confirmed the effectiveness to extract useful information from biological materials by combining polarization and light scattering,1 many polarization parameters (differential polarization,2 the degree of polarization,3,4 Mueller matrix,58 etc.) and polarization scattering models (sphere-birefringence model9 and sphere-cylinder-scattering model1012) have been put forward to describe the distinctive pathological features. However, for certain biological tissues containing pigment like melanin or chromatophores like chloroplast, the inherent absorbing effect in ambient media or on scatterers make the polarized light propagation in such absorptive media different.

For the absorption effect in ambient media, Li et al. proposed a skin model containing a top isotropic layer, a bottom anisotropic layer, and an absorbing medium to explain the contrast mechanism of polarization imaging for melanoma.13 Dmitry et al. proposed an approximate expression to describe the dependence of the degree of residual linear polarization on the absorption of scattering media.14 Swami et al. studied how the absorption of the scattering medium containing spherical scatterers and absorbing medium affects the depolarization.15 For absorption on the scatterers, Kienle et al. considered the imaginary part of the scatterers’ complex refractive index for multiple scattering of polarized light propagation in turbid media, and evaluated the whole angle-dependent Mueller matrix by comparing results of polarization sensitive radiative transfer solution with Maxwell theory.16 Mishchenko et al. employed the numerically exact superposition T-matrix method to demonstrate that the increasing absorption of particles diminishes and nearly extinguishes certain optical effects such as depolarization and coherent backscattering.13

Our previous work has developed an optical scattering model called the sphere-cylinder-birefringence model (SCBM) to simulate and simplify complicate and anisotropic biological tissues.12 Two sets of polarization parameters extracted from the Mueller matrix transformation and Mueller matrix polar decomposition (MMPD) techniques have been used to test this model and explain some pathological changes.1621 However, considering the possible absorption in real biological tissues, it is necessary to include the absorbing effect in this model and explore the consequent change of these polarization parameters. This paper studies the absorption in ambient media and the induced impact on polarization parameters; absorption on the scatterers will be discussed in our further research. A Monte Carlo program was used to trace the polarization status of polarized photons scattered by the spheres and cylinders and propagating in a medium including absorption and birefringent effects. Experiments were carried out on forward scattering Mueller matrix measurements of samples containing polystyrene microspheres, well-aligned glass fibers, and absorbing ink solution. Both experiments and simulation results indicate how the absorption effect during the light transmission affects the MMPD parameters.

2.

Theory

2.1.

Monte Carlo Simulation and SCBM

MMPD proposed by Lu-Chipman can quantitatively decompose the measured Mueller matrix into the product of three factors to determine its diattenuation, retardance, and depolarization21

Eq. (1)

M=MΔMRMD.

The matrices MΔ, MR, and MD represent the polarization parameters of depolarization, retardance, and diattenuation, respectively. The value of diattenuation D could be calculated from MD matrix as follows:

Eq. (2)

D=1m11(m122+m132+m142).

The depolarization coefficient Δ could be determined from the elements of matrix MΔ:

Eq. (3)

Δ=1|tr(MΔ)1|3.

The last MMPD parameter retardance R could be calculated from MR and is divided into two types of retardance, the linear retardance δ and the circular retardance ψ, which in other words is called optical activity:

Eq. (4)

R=cos1[tr(MR)21],

Eq. (5)

δ=cos1{[MR(2,2)+MR(3,3)]2+[M(3,2)MR(2,3)]21},

Eq. (6)

ψ=tan1[MR(3,2)MR(2,3)MR(2,2)+MR(3,3)].

2.2.

Monte Carlo Simulation and SCBM

A Monte Carlo simulation program was used to track and record the polarization status of photons propagating in anisotropic scattering media with optical absorption. This simulation program is on the basis of our previously proposed sphere-cylinder birefringence model (SCBM), which describes the anisotropic media like biological tissues as a mixture consisting of spherical and cylindrical scatterers, corresponding to the microstructural and optical properties of cells and fibrous tissues in organism.12 Here, we introduce the absorption effect in the intercellular substance and make it adjustable in this model. Other parameters in this model can also be adjustable to simulate different types of tissue samples. For scatterers, the variable parameters include the sizes, refractive indices, scattering coefficients of spheres and cylinders, and the orientation angular distribution of cylinders. For the surrounding medium, the variable parameters include thickness, refractive index, absorbing coefficient or birefringence, dichroism, and optical activity coefficient.

We calculate the scattering coefficients of spheres based on the known concentration, sphere size, and refractive index according to Mie theory. For the case of a cylinder, the scattering coefficient is not only related to the density, diameter, and refractive index but also varies with incident polarization status and the angle between the direction of incident photon and the cylinder. During calculations, we should first determine this angle according to the spatial orientation of the cylinder and the propagation direction of the photon, and then follow the theory of polarized photon scattering at an infinitely long cylinder, which has been demonstrated in detail in Ref. 13. The scattering coefficient of a microsphere is a constant once its size and refractive index are set. However, the scattering coefficient of cylinders μs,cyl varies with the angle ζ between the direction of incident photon and the cylinder:11,22

Eq. (7)

μs,cyl(ζ)=Qsca(ζ)·d·CA,
where d and CA are the diameter and density of the cylinders. Qsca is the scattering efficiency of a single cylinder. It is a function of the angle ζ and the polarization state of the incident photon. In the program, we first determine ζ according to the spatial orientation of the cylinder and the propagation direction of the photon. The efficiency Qsca can be calculated using the analytic solution of the Maxwell equation.11,23

2.3.

Experiment Setup

The experiment setup for forward scattering Mueller matrix measurement is shown in Fig. 2. A 3-W LED is used as the light source with its center wavelength of 650 nm. After beam expansion and collimation, the incident light passes through a set of a linear polarizer and quarter wave plate and could be modulated into six types of polarization states: horizontal linear (H), vertical linear (V), 45-deg linear (P), 135-deg linear (M), and right/left circular (R/L). The scattering light exiting from samples is examined by the analyzer, which is also a set of quarter wave plate and linear polarizer, and finally is collected by a lens and recorded by a CCD (Q-imaging Retiga Exi, 12-bit). For each incident polarization state, six components of the forward scattering light are detected through the analyzer. The Mueller matrix can be calculated through the 36 raw images accordingly:

Eq. (8)

M=(m11m12m13m14m21m22m23m24m31m32m33m34m41m42m43m44)=12(HH+HV+VH+VVHH+HVVHVVPH+PVMPMMHHHV+VHVVHHHVVH+VVPHPVMHMVHPHM+VPVMHPHMVP+VMPPPMMP+MMVR+HRLLRLVL+HRHLVRML+PRPLMRRH+RVLHLVRHRVLH+LVRPRMLP+LMRR+LLLRRL).

In Eq. (8), the first letter of Mueller elements represents input polarization state, and the second letter represents the states of polarization analyzer. In experiments, we define a reference coordinate system with its x axis parallel to the optical platform and y axis perpendicular to it. As shown in Figs. 1 and 2, the surface of sample is set to xy plane, and the incident light passes through the sample along z axis.

Fig. 1

Schematic of SCBM.

JBO_23_12_121609_f001.png

Fig. 2

The forward scattering Mueller matrix measurement setup schematic. LED, light source; L1, L2: lenses; P1, P2: lenses; QW1, QW2: quarter wave plate, the sample position corresponding to Fig. 1 is shown in the dashed frame.

JBO_23_12_121609_f002.png

The measured anisotropic and absorbing samples contain polystyrene microspheres and well-aligned glass fibers immersed in absorbing ink solution. The diameter and refractive index of polystyrene microspheres are 1  μm and 1.59, respectively. The glass fibers, with the diameter of 10  μm and the refractive index of 1.547, are arranged in alignment and wrapped neatly around the metal frame, which is immersed in the middle of the ink solution. The ink solution is configurable for concentration and is filled in a 5  cm×0.5  cm×3  cm cuvette. Different concentrations of ink solution represent different absorbing coefficients. The MMPD method is used to characterize the polarization properties of samples and investigate the influence of the absorption effect on corresponding parameters.

3.

Results and Discussion

To study the change of full polarization information with the increasing absorption effect, all Mueller matrix elements are simulated using our Monte Carlo polarization scattering simulation program and SBM anisotropic tissue model. Figure 3 shows the spatial distribution spectrum patterns of all Mueller elements. Here, different color curves represent different absorption coefficients. The vertical axes of the subplots represent the analyzed polarized intensity, whose unit is equal to the calculated photon number during the polarized light scattering process. The lateral axis is the spatial location of photon emission, whose value represents the pixel sequence number of the simulated detection plane where the incident spot center is on pixel 100.

Fig. 3

Spatial distribution patterns of Mueller elements under different optical absorptions based on Monte Carlo simulations of SCBM: (a) SCBM with a sphere-cylinder ratio of 10:50; (b) SCBM with a sphere-cylinder ratio of 30:30; and (c) normalized patterns of (a).

JBO_23_12_121609_f003.png

Figures 3(a) and 3(b) show two SCBM models with a sphere-cylinder ratio of 10:50 and 30:30, respectively, and Fig. 3(c) shows normalized processed patterns using the same model as Fig. 3(a). We focus on the optical absorption induced polarization characterization for an anisotropic medium. The proportion of cylindrical scatterers is a typical factor to describe the tissue anisotropy according to our previous work,4 so we study the influence of the anisotropy of scattering media using the two cases of different sphere-cylinder ratios [Figs. 3(a) and 3(b)]. Furthermore, in Fig. 3(c), by normalization, we remove the scattered intensity change due to absorption and make the polarization-related phenomena clear.

From this figure, we can see that most of the elements can be influenced by the interstitial absorption except for m13, m14, m31, and m41, and the tissue model with a high anisotropy will be affected more by comparison of Figs. 3(a) and 3(b). After normalization, we can see that the relative change of nondiagonal elements with the increasing absorption is not so obvious, and the value of diagonal elements on all the spatial locations can be uniformly decreased gradually by absorption. Generally, the additional absorption phenomena in tissue models can cause the scattering intensity change of light with different incident polarization states, implying diattenuation behavior during the light scattering. Also, the apparent change of diagonal elements and the m34 and m43 indicate the influence of absorption on depolarization and phase retardance processes.

In our previous study, we pointed out that, for SCBM, spherical scatterers only contribute to depolarization, but cylindrical scatterers contribute to diattenuation, depolarization, and partial retardance (the rest comes from birefringence of the medium).21 Now we consider the influence of the absorbing coefficient of the surrounding medium by MMPD parameters. Figures 4(a)4(c) show simulation results, respectively, of the diattenuation, depolarization, and linear retardance with the increasing absorption. In this SCBM, the diameters of spheres and cylinders are 1 and 10  μm, their refractive indices are 1.59 and 1.547. The birefringence of the ambient medium remains 2×106. Considering various tissue anisotropy, we simulated three models marked by different colors in Fig. 4 with different ratios of spherical scattering coefficient and cylindrical scattering coefficient: 0:60, 10:50, and 30:30, respectively. Figures 4(b) and 4(c) clearly point out the negative correlation between the depolarization and the linear retardance parameters with the absorption coefficient. On the contrary, the diattenuation values due to cylinders show a positive correlation with absorption. Moreover, the enhanced diattenuation and the weakened retardance seem more obvious for the scattering model with a higher anisotropy. We use polystyrene microspheres and glass fibers to mimic spherical and cylindrical scatterers for the experimental verification, shown in Figs. 4(d)4(f). When preparing the polyacrylamide gel, for the stability of the gelation process, we can employ only diluted ink solution to introduce the absorption effect of the surrounding media. As for glass fibers, we wrap them in alignment around a metal frame and then immerse them in the middle of the microsphere solution containing the ink solution. Compared with simulations, the linear retardance is smaller because we cannot simultaneously introduce absorption and birefringence into the surrounding medium in experiments. However, the results still reveal the similar regularity that the increasing absorption enhances the diattenuation but depresses retardance and depolarization.

Fig. 4

MMPD results: (a)–(c) Monte Carlo simulation of SCBM and (d)–(f) experiments of sphere-cylinder scattering model.

JBO_23_12_121609_f004.png

For SCBM, we also can modify the tissue anisotropy by the spatial orientation distribution of cylinders. We assume that the orientation of cylindrical scatterers follows a Gaussian distribution function and the FWHM of this function can be used to describe the order of alignment. A bigger FWHM means a more disordered distribution of cylinders, which can significantly reduce the anisotropy of system. So we can simulate the influence on MMPD characters of the absorption coefficient with different orientation distributions of cylinders, as shown in Figs. 5(a)5(c), where the FWHM of the cylinder distribution function is set to 5 deg, 10 deg, and 20 deg, and their main orientations are along with the direction of x axis shown in Fig. 1. The scattering coefficients of spheres and cylinders are, respectively, 10 and 50  cm1. Their diameters are, respectively, 1 and 10  μm. The birefringence of ambient medium is set to 2×106. Similarly with Fig. 4, for one thing, these results confirm again that the absorption effect in the ambient medium can surely enhance the diattenuation but reduce depolarization and linear retardance. For another, the influence of the optical absorption effect also varies with different degrees of tissue anisotropy. In Figs. 5(a) and 5(c), the change of diattenuation and linear retardance is clearer for the red line with the smallest FWHM value meaning a more orderly arrangement of cylinders. In order to exclude the distinctiveness of the above simulation results on absorption caused by the main orientation angle of cylinders, we set other three different orientation angles in the following simulations. As shown in Figs. 5(d)5(f), the red, green, and blue lines, respectively, represent the simulation with the main orientation angle of 0 deg, 30 deg, and 45 deg between the axial direction of cylinders and x axis. It can be seen that the qualitative impact of absorption effects on decomposition parameters remains the same.

Fig. 5

MMPD results: (a)–(c) Monte Carlo simulation of SCBM with different FWHM of cylinder orientation distribution function while the main orientation remains the direction of x axis. (d)–(f) Monte Carlo simulation of SCBM with different main orientation angles of cylinders while the FWHM of the orientation distribution function remains 5 deg.

JBO_23_12_121609_f005.png

Next, we consider another anisotropic factor in our SCBM tissue model, i.e., the birefringence effect in the ambient medium. As shown in Fig. 6, we change the absorption coefficient in our SCBM models with different birefringence of 0, 2×106, 4×106 colored with red, green, blue markers in sequence. The diameters of spheres and cylinders are, respectively, 1 and 10  μm, and the scattering coefficient of spheres and cylinders are, respectively, 10 and 50  cm1. The FWHM of cylinder orientation distribution function remains 5 deg. Here the red line with Δn=0 shows the linear retardance totally produced by cylinder scattering; the retardance difference among different color results originates from the birefringence induced retardance. Consistent with the above figures, the optical absorption can cause decreased retardance, however, the parallel colored lines in Fig. 6 imply that the influence of absorption on retardance parameter is independent with the birefringence effect in the surrounding medium, and the decrease of the shown retardance curves is due to the depressed scattering process by absorption.

Fig. 6

MMPD results of SCBM with different birefringence in ambient medium.

JBO_23_12_121609_f006.png

Combined with the above three figures, we can find that the additional optical absorption do have impact on polarization processes and apparently depress the depolarization and linear retardance, however, enhance the biattenuation. By comparison, the influence of absorption varies with the degree of scattering anisotropy in the simulated tissue models and SCBM models with more cylindrical elements or a highly ordered orientation seem sensitive to the optical absorption. The existence of birefringence and the main orientation angle do not affect how MMPD parameters change with the absorption coefficient, and conversely the optical absorption cannot change the contribution of birefringence on tissue anisotropy.

The following discussions try to explain the impact of absorption effect in ambient medium on scattering induced diattenuation, depolarization, and linear retardance. First, for diattenuation, we start from its definition as

Eq. (9)

D=(m122+m132+m142)m11.

In SCBM, when the orientation of the cylinder is set along x axis, we can approximate D as the following expression considering the value of matrix element m13 and m14 are much smaller than that of m12:

Eq. (10)

D=|m12|m11=|HIVI|HI+VI.

Here “HI” represents the intensity of scattered light in the case of the horizontal polarized incident light, and “VI” represents the intensity of scattered light in the case of the vertical polarized incident light. Using one set of the above data as an example, in which the scattering coefficients of spheres and cylinders are 10 and 50  cm1, the FWHM of cylinders orientation distribution function is 5 deg, and the birefringence of ambient medium is 2×106, we investigate how the |HIVI|/(HI+VI) vary with the absorption coefficient. As shown in Fig. 7(a), |HIVI|/(HI+VI) show the same changing trend as the red line in Fig. 5(a), which confirms that D reflects the scattering difference for two orthogonal linear polarization incidences in this model, like Fig. 7(b). Theoretically for isotropic scattering media without irregular scatterers and optical anisotropy, the scattered photon behaviors of orthogonal linear polarization incidence light are equal. However, the existence of anisotropic factors in the tissue model, like cylindrical scatterers, can cause polarization response during scattering sensitive to the incident polarization status. As shown in Fig. 7(c), we can see that the phase function of cylinder depends on the polarization state of incident light. When the scattering angle ranges from 0 deg to 45 deg, the horizontal polarized light has nearly the same phase function as the vertical polarized light. While when the scattering angle ranges from 45 deg to 90 deg, the phase function of the horizontal polarized light is clearly bigger than that of the vertical polarized light, thus indicating a bigger lateral scattering possibility for horizontal polarized incident light. Correspondingly during the scattering process, the horizontal polarized incident light may undergo more lateral scattering steps and has a longer optical path when scattered by cylindrical scatterers. As a consequence, the scattered behavior of horizontal polarized light will be more affected than the vertical polarized light by the absorption effect in the ambient medium, which leads to the enhanced difference of HI and VI and finally produces a bigger diattenuation.

Fig. 7

(a) and (b) The function of |HIVI|/(HI+VI) and HI/VI with absorption coefficient and (c) the scattering phase function of cylinder.

JBO_23_12_121609_f007.png

In order to explain the impact of absorption on scattering induced depolarization and linear retardance, we analyze the photon behaviors in SCBM with various absorption extents shown in Fig. 8. As we can see, the enhanced absorption depresses the multiscattered photons more and thus results in decreased total scattering numbers. For the absorption effect in the surrounding media, the absorption can cause additional light attenuation between one and the next scattering event. So the multiple scattered photons mean more absorption probability and show a clearly declined proportion with the increase of the absorption setting value. For the SCBM tissue model and the forward detection scheme, not only is the depolarization phenomena related to the multiple scattering, but also the phase retardance is contributed by the scattering of anisotropic cylinders, so the depressed multiple scattering by absorption can produce a lower depolarization and retardance.

Fig. 8

The distribution of the scattering number of the forward scattering photons.

JBO_23_12_121609_f008.png

Finally, we pay attention to the cylindrical scatterers with the special orientation angles not on the surface plane, as shown in Fig. 9. It can be seen that the change trend of diattenuation and depolarization items [Figs. 9(a) and 9(b)] seems similar to Fig. 5. So, the discussion about the influence of optical absorption on these two processes is still valid even for the fibrous microstructures not perpendicular to the incident light and not on the surface plane. However, as shown in Fig. 9(c), the phase retardance increases along with the increasing absorption. These simulation results seem different from the case of cylinders perpendicular to incident light, but actually, we can provide an explanation based on our previous research.24 Concretely, the total retardance depends on the coupling of two parts of retardances, respectively, from birefringence and cylindrical scatterers, closely related to the interception angle between the orientation of birefringence and cylinders. Based on the above results and discussions in this paper, the cylinder induced retardance can be decreased due to the reduced scattering times by absorption. But for the case of Figs. 9(a)9(c), the main orientation angle of cylinders is on xz plane and the interception angle from the birefringence axis (x axis) is equal to 90 deg, where the retardance induced by birefringence and cylinders will cancel each other first, as demonstrated in Ref. 24. It means that even less contribution from cylinders could restrain such canceling out between different retardance sources and cause the enhanced total retardance, which can explain the increased simulated retardance in Fig. 9(c) in this paper with the increasing optical absorption.

Fig. 9

MMPD results: (a)–(c) Monte Carlo simulation of SCBM with different orientation angles on xz plane and (d) schematic diagram of SCBM model.

JBO_23_12_121609_f009.png

4.

Conclusion

In this paper, we focus on the influence of absorption effect on Mueller matrix. By Monte Carlo simulation on our previously proposed SCBM and forward scattering experiments on phantoms containing polystyrene microspheres, well-aligned glass fibers, and ink solution, we analyze the changing trend of Mueller matrix and MMPD parameters with the absorption coefficient. Both simulation and experiment results can indicate that optical absorption in the medium can cause an enhanced diattenuation evaluation and reduce the scattering induced depolarization and linear retardance. The increasing diattenuation can be explained by the different scattering phase functions of cylindrical scatterers for horizontal polarized incident light and vertical polarized incident light. The weakened depolarization and linear retardance should be due to the decrease of multiple scattering photons. However, the linear retardance caused by the intrinsic birefringence in the medium is insensitive to the absorption effect. These simulations and experiments imply that optical absorption affects the change regularity of polarization state of polarized light in tissues, and also show possible potential of polarization parameters used in tissue characterization involving absorption effect.

Disclosures

The authors have no relevant financial interests in this article and no potential conflicts of interest to disclose.

Acknowledgments

This work was supported by the National Key R&D Program of China (Nos. 2016YFC0208600 and 2016YFF0103000) and the National Natural Science Foundation of China (NSFC) (No. 41475125).

References

1. 

W. S. Bickel et al, “Application of polarization effects in light scattering: a new biophysical tool,” Proc. Natl. Acad. Sci. U.S.A., 73 (2), 486 –490 (1976). https://doi.org/10.1073/pnas.73.2.486 Google Scholar

2. 

R. R. Anderson, “Polarized light examination and photography of the skin,” Arch. Dermatol., 127 (7), 1000 –1005 (1991). https://doi.org/10.1001/archderm.1991.01680060074007 Google Scholar

3. 

S. L. Jacques, J. R. Roman and K. Lee, “Imaging superficial tissues with polarized light,” Lasers Surg. Med., 26 (2), 119 –129 (2000). https://doi.org/10.1002/(ISSN)1096-9101 LSMEDI 0196-8092 Google Scholar

4. 

S. L. Jacques, J. C. Ramella-Roman and K. Lee, “Imaging skin pathology with polarized light,” J. Biomed. Opt., 7 (3), 329 –340 (2002). https://doi.org/10.1117/1.1484498 JBOPFO 1083-3668 Google Scholar

5. 

N. Ghosh and I. A. Vitkin, “Tissue polarimetry: concepts, challenges, applications, and outlook,” J. Biomed. Opt., 16 (11), 110801 (2011). https://doi.org/10.1117/1.3652896 JBOPFO 1083-3668 Google Scholar

6. 

B. D. Cameron, Y. Li and A. Nezhuvingal, “Determination of optical scattering properties in turbid media using Mueller matrix imaging,” J. Biomed. Opt., 11 (5), 054031 (2006). https://doi.org/10.1117/1.2363347 JBOPFO 1083-3668 Google Scholar

7. 

T. Novikova et al, “The origins of polarimetric image contrast between healthy and cancerous human colon tissue,” Appl. Phys. Lett., 102 (24), 241103 (2013). https://doi.org/10.1063/1.4811414 APPLAB 0003-6951 Google Scholar

8. 

Y. A. Ushenko et al, “Muellermatrix diagnostics of optical properties of polycrystalline networks of human blood plasma,” Opt. Spectrosc., 112 (6), 884 –892 (2012). https://doi.org/10.1134/S0030400X12050232 OPSUA3 0030-400X Google Scholar

9. 

L. H. Wang, S. L. Jacques and L. Zheng, “Monte Carlo modeling of photon transport in multilayered tissues,” Comput. Methods Programs Biomed., 47 131 –146 (1995). https://doi.org/10.1016/0169-2607(95)01640-F CMPBEK 0169-2607 Google Scholar

10. 

H. He et al, “Two-dimensional backscattering Mueller matrix of sphere-cylinder scattering medium,” Opt. Lett., 35 (14), 2323 –2325 (2010). https://doi.org/10.1364/OL.35.002323 OPLEDP 0146-9592 Google Scholar

11. 

T. Yun et al, “Monte Carlo simulation of polarized photon scattering in anisotropic media,” Opt. Express, 17 (19), 16590 –16602 (2009). https://doi.org/10.1364/OE.17.016590 OPEXFF 1094-4087 Google Scholar

12. 

E. Du et al, “Two-dimensional backscattering Mueller matrix of sphere-cylinder birefringence media,” J. Biomed. Opt., 17 (12), 126016 (2012). https://doi.org/10.1117/1.JBO.17.12.126016 JBOPFO 1083-3668 Google Scholar

13. 

D. Li et al., “Influence of absorption in linear polarization imaging of melanoma tissues,” J. Innovative Opt. Health Sci., 7 1450009 (2014). https://doi.org/10.1142/S1793545814500096 Google Scholar

14. 

D. N. Agafonov et al., “Influence of absorption on residual polarization of backscattered linearly polarized light,” Int. Soc. Opt. Photonics, 166 –172 (2002). https://doi.org/10.1117/12.469007 Google Scholar

15. 

M. K. Swami et al., “Mueller matrix measurements on absorbing turbid medium,” Appl. Opt., 49 (18), 3458 –3464 (2010). https://doi.org/10.1364/AO.49.003458 APOPAI 0003-6935 Google Scholar

16. 

A. Hohmann et al., “Multiple scattering of polarized light: influence of absorption,” Physics in medicine and biology, 59 (11), 2583 –2597 (2014). https://doi.org/10.1088/0031-9155/59/11/2583 PHMBA7 0031-9155 Google Scholar

17. 

M. I. Mishchenko, L. Liu and J. W. Hovenier, “Effects of absorption on multiple scattering by random particulate media: exact results,” Optics express, 15 (20), 13182 –13187 (2007). https://doi.org/10.1364/OE.15.013182 OPEXFF 1094-4087 Google Scholar

18. 

E. Du et al., “Mueller matrix polarimetry for differentiating characteristic features of cancerous tissues,” J. Biomed. Opt., 19 (7), 076013 (2014). https://doi.org/10.1117/1.JBO.19.7.076013 JBOPFO 1083-3668 Google Scholar

19. 

Y. Guo et al, “A study on forward scattering Mueller matrix decomposition in anisotropic medium,” Opt. Express, 21 (15), 18361 –18370 (2013). https://doi.org/10.1364/OE.21.018361 OPEXFF 1094-4087 Google Scholar

20. 

S. Y. Lu and R. A. Chipman, “Interpretation of Mueller matrices based on polar decomposition,” J. Opt. Soc. Am. A, 13 (5), 1106 –1113 (1996). https://doi.org/10.1364/JOSAA.13.001106 JOAOD6 0740-3232 Google Scholar

21. 

H. He et al., “A possible quantitative Mueller matrix transformation technique for anisotropic scattering media,” Photonics Lasers Med., 2 (2), 129 –137 (2013). https://doi.org/10.1515/plm-2012-0052 Google Scholar

22. 

A. Kienle et al, “Light propagation in dentin: influence of microstructure on anisotropy,” Phys. Med. Biol., 48 N7 –N14 (2003). https://doi.org/10.1088/0031-9155/48/2/401 PHMBA7 0031-9155 Google Scholar

23. 

C. F. Bohren and D. R. Huffman, Absorption and Scattering of Light by Small Particles, John Wiley and Sons, New York (1983). Google Scholar

24. 

Y. H. Guo et al., “Retardance of bilayer anisotropic samples consisting of well-aligned cylindrical scatterers and birefringent media,” J. Biomed. Opt., 21 (5), 055002 (2016). https://doi.org/10.1117/1.JBO.21.5.055002 JBOPFO 1083-3668 Google Scholar

Biography

Nan Zeng received her PhD from Tsinghua University, Beijing, China, in 2005. Currently, she is an associate professor in the Graduate School at Shenzhen, Tsinghua University, Shenzhen, China. Her research interests include noninvasive online aerosol analysis and tissue characterization using polarization equipment and simulations.

Hui Ma received his PhD in atomic and molecular physics from Imperial College London, UK, in 1988. He joined the Department of Physics, Tsinghua University, China, in 1991 and moved to Shenzhen in 2003. Currently, he is a professor with the Tsinghua Graduate School at Shenzhen, China, and the Tsinghua-Berkeley Shenzhen Institute, Shenzhen, China. His research interests include polarimetry techniques and their applications which include diagnosis and staging of cancers, differentiation of marine particles and algae, and tracing micron-scale pollutant particles in air.

Biographies for the other authors are not available.

CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Yunfei Wang, Yu Huang, Nan Zeng, Yihong Guo, Yonghong He, and Hui Ma "Study on the influence of optical absorption on polarization characterization of tissues," Journal of Biomedical Optics 23(12), 121609 (27 October 2018). https://doi.org/10.1117/1.JBO.23.12.121609
Received: 13 June 2018; Accepted: 19 September 2018; Published: 27 October 2018