Open Access
15 February 2024 In vivo visualization of burn depth in skin tissue of rats using hemoglobin parameters estimated by diffuse reflectance spectral imaging
Md. Anowar Parvez, Kazuhiro Yashiro, Yuki Nagahama, Yasuyuki Tsunoi, Daizoh Saitoh, Shunichi Sato, Izumi Nishidate
Author Affiliations +
Abstract

Significance

Burn injuries represent a global public health problem that kills an estimated 180,000 people annually. Non-fatal burns result in prolonged hospitalization, disfigurement, and disability. The most common, convenient, and widely used method for assessing burn depth is physical or visual examination, but the accuracy of this method is reportedly poor (60% to 75%). Rapid, correct assessment of burn depth is very important for the optimal management and treatment of burn patients. New methods of burn depth assessment that are inexpensive, simple, rapid, non-contact, and non-invasive are therefore needed.

Aim

The aim of this study was to propose an approach to visualize the spatial distribution of burn depth using hemoglobin parameters estimated from spectral diffuse reflectance imaging and to demonstrate the feasibility of the proposed approach for differentiating burn depth in a rat model of scald burn injury.

Approach

The new approach to creating a spatial map of burn depth was based on canonical discriminant analysis (CDA) of total hemoglobin concentration, tissue oxygen saturation, and methemoglobin saturation as estimated from spectral diffuse reflectance images. Burns of three different degrees of severity were created in rat dorsal skin by 10-s exposure to water maintained at 70°C, 78°C, and 98°C, respectively. Spectral images for dorsal regions were acquired under anesthesia immediately after burn injury and at 24 h, 48 h, and 72 h after injury.

Results

Most areas of images in the group with skin exposed to 70°C water and 98°C water were classified as 70°C burn and 98°C burn, respectively. In contrast, no significant difference between areas classified as 78°C burn and 98°C burn from 24 h to 72 h was evident in the group with skin exposed to 78°C water, suggesting that burn depth was heterogeneous.

Conclusions

The proposed approach combining diffuse reflectance spectral imaging and CDA appears promising for differentiating 70°C burns from 78°C burns and 98°C burns, and 98°C burns from 70°C burns and 78°C burns at 24 to 72 h after burn injury in a rat model of scald burn injury.

1.

Introduction

Burns are one of the most serious, dangerous, and unpredictable forms of trauma. In the management and treatment of burns patients, assessment of burn depth is crucial. Clinicians typically classify burns according to depth as superficial burns, superficial dermal burns (SDBs), deep dermal burns (DDBs), and deep burns (DBs).1 Superficial burns affect only the superficial layer of the epidermis2 and so are typically painful, but they heal without scarring and require no special care.3 SDBs are also associated with the epidermal layer, but are more painful, involving blister formation, weeping, and scar tissue. SDBs are very susceptible to infection and therefore require special treatment and care to prevent infection, but do not require surgery.3,4 DDBs, also known as deep partial-thickness burns, involve the epidermis and a portion of the dermis, extending 2 to 3 mm into the deep dermis.4 While less painful, DDBs form more scar tissue. Special care is needed, and surgery may be required.3 DBs, also known as full-thickness burns, involve all layers of the epidermis and dermis, resulting in little to no pain due to massive nerve damage. Large areas of skin grafting and special care are required.3

Although proper and rapid assessment of burn depth is very important for optimal management and treatment of the burn patient, distinguishing between SDBs, DDBs, and DBs is very difficult because burn depth increases with progression of the burn5 and decreases with natural healing. Overestimation of burn depth can lead to unnecessary surgery, while underestimation leads to delayed surgery and prolonged hospitalization.6 Early, rapid, correct, and accurate differentiation between SDBs, DDBs, and DBs thus remains a challenge and a top research priority in the field of burns treatment.710 Several methods and techniques are used to estimate burn depth. The most common is visual examination by the physician along with a report of pain sensation by the patient, together known as physical examination.11 However, the accuracy of this approach is very low, at 60% to 75% based on clinical experience.12

Histopathological examination allows reliable assessment of burn depth but is invasive.13 Other advanced methods for objectively assessing burn depth have been investigated, including indocyanine green dye fluorescence imaging,14 infrared thermal imaging,15 ultrasound imaging,1618 laser Doppler imaging,19 confocal laser scanning microscopy,20 photoacoustic imaging,21 spatial frequency domain imaging,22 and nuclear magnetic resonance imaging.23

Diffuse reflectance spectral imaging (DRSI) is a promising, non-invasive clinical diagnostic technique achieved using simple optical components and devices. DRSI can simultaneously quantify the in vivo concentration and oxygen saturation of hemoglobin at each pixel in an image, allowing the assessment of various physiological conditions in living tissues.5,6,2429 Burns can change the skin hemodynamics, showing significant increases in the methemoglobin content within a tissue as well as oxygenated hemoglobin and deoxygenated hemoglobin, depending on the severity and depth of the burn.30,31

We have already developed a DRSI method for quantifying melanin, oxygenated hemoglobin, deoxygenated hemoglobin, and methemoglobin in skin tissues and demonstrated spatiotemporal changes in peripheral hemodynamics in rats during methemoglobinemia.32 We also found that canonical discriminant analysis (CDA) with total hemoglobin concentration (CHbT), tissue oxygen saturation (StO2), and methemoglobin saturation (StMet) is promising for differentiating between degrees of burns injuries.33 In this study, we propose an approach to spatially map burn severity in skin tissue using the CDA for values of CHbT, StO2, and StMet estimated from DRSI. This study aimed to demonstrate the feasibility of this method for differentiating between burn depths in a rat model of scald burn injury.

2.

Materials and Methods

2.1.

Production of Burn Wounds

All experimental procedures were performed in accordance with the protocols approved by the Animal Care Committee of the Tokyo University of Agriculture and Technology (approval nos. R03–185 and R04–136). Thirty-three male Sprague–Dawley rats (10 to 12 weeks old; body weight, 210 to 280 g; Tokyo Laboratory Animals Science Co., Tokyo, Japan) were used in this study. Rats were divided into 70°C burn, 78°C burn, and 98°C burn groups, with 11 rats in each group. Anesthesia was induced in rats with isoflurane (1%, 2  mL/min) and maintained at a depth such that the rat showed no response to toe pinching. After the induction of anesthesia, the dorsal and head regions were shaved, and a depilatory agent containing thioglycolic acid was applied to both regions. Before producing the burn wound, carprofen (5  mg/kg) was injected intramuscularly for pain relief. 70°C burns, 78°C burns, and 98°C burns were induced in rat dorsal skin by exposing skin comprising 20% of the total body surface area (4  cm×10  cm) to water maintained at 70°C, 78°C, and 98°C, respectively, for 10 s using a Walker–Mason template.34 This protocol has been established, and the results of histological examinations confirmed that the burn severities of 70°C burn, 78°C burn, and 98°C burn correspond to SDB, DDB, and DB.35,36 Immediately after producing the burns, rats were resuscitated with intraperitoneal injection of saline solution (25  mL/kg). Carprofen (5  mg/kg) was injected intramuscularly twice daily for postoperative pain relief. The wound surface was covered with a moist wound dressing sheet (PA1A; Zuiko Medical Corp., Osaka, Japan) and wrapped in bandages (Daiei Co., Osaka, Japan). Each rat was kept in an independent cage at 50% humidity and a temperature of 24°C with ad libitum access to food and water.

2.2.

Hyperspectral Image Data Collection

Figure 1 shows the experimental apparatus used in this study. A halogen lamp light source (LA-150SAE; Hayashi Watch Works Co., Tokyo, Japan) was used to illuminate the sample surface via a light guide with a ring-shaped illuminator. Diffusely reflected light was received by a hyperspectral camera (NH-NSD; EBA JAPAN, Tokyo, Japan) with a camera lens to acquire a hyperspectral cube. The camera has an internal optical stage-scanning system comprising a slit, a collimating lens, a transmission diffraction grating, a relay lens, and a two-dimensional (2D) charge-coupled device detector sensor. Hyperspectral image data ranging from 400 to 1000 nm at 10-nm intervals were captured and recorded on a personal computer. The field of view for the system was an area of 32.6×24.5  mm2 with 640×480  pixels. Lateral resolution of images was estimated to be 51  μm. A standard white diffuser with 99% reflectance (SRS-99-020; Labsphere, North Sutton, New Hampshire) was used to correct for inter-instrument differences in camera output and the spatial non-uniformity of illumination. A ring-shaped polarizer and an analyzer were set in a crossed Nicols alignment to reduce specular reflection from the skin surface. Total acquisition time for one hyperspectral cube was 13 s. Experiments were performed in a darkroom to prevent the effects of ambient light on spectral imaging. Ambient light therefore had no significant effect on imaging. Sets of spectral images for both dorsal and head regions were acquired pre-burn and immediately post-burn under anesthesia. Subsequent measurements were performed at 24, 48, and 72 h after injury. Sequential spectral images of the dorsal region were acquired from all rats in each group while those of the head region (non-injured skin) were acquired from four rats in each group. Euthanasia was the endpoint of the study and the time of last spectral image data collection. Once sequential data collection had been completed, animals were euthanized by overdose of isoflurane (5%, 2  mL/min) until 1 min after breathing stopped.

Fig. 1

Schematic illustration of the imaging system.

JBO_29_2_026003_f001.png

2.3.

Data Processing for Imaging Hemoglobin Parameters

We had already developed an imaging method for quantifying melanin, oxygenated hemoglobin, deoxygenated hemoglobin, and methemoglobin contents in skin tissues and visualizing spatiotemporal changes in peripheral hemodynamics in rats during methemoglobinemia.33 This method was leveraged in this study to evaluate concentrations of methemoglobin, oxygenated hemoglobin, and deoxygenated hemoglobin in the rat model of burns injury. Briefly, multiple regression analysis was performed using the absorbance spectrum calculated from the measured diffuse reflectance spectrum of rat skin between 550 and 680 nm as a response variable and the known extinction coefficient spectra of melanin, oxygenated hemoglobin, deoxygenated hemoglobin, and methemoglobin as predictor variables to provide multiple regression coefficients. Concentrations of melanin (Cm, vol. %), oxygenated hemoglobin (CHbO, vol. %), deoxygenated hemoglobin (CHbR, vol. %), and methemoglobin (CmetHb, vol. %) were then determined from regression coefficients using empirical formulas that were deduced numerically in advance. A Monte Carlo simulation (MCS) of light transport37 in a human skin model was carried out to numerically establish the empirical formulas. We assumed that whole blood with 150  g/L of hemoglobin represents a 100% volume concentration of total hemoglobin (CHbT=100 vol. %) and is uniformly distributed in the dermis. The volume concentration in this case represents the percentage of blood in a unit volume of dermis. Values of CHbO, CHbR, CmetHb, and Cm were estimated for each pixel. CHbT (vol. %), StO2 (%), and StMet (%) were also calculated. The sum of the values of CHbO, CHbR, and CmetHb represents the volume concentration of total hemoglobin CHbT. Values of StO2 and StMet were calculated as 100×(CHbO/CHbT) and 100×(CmetHb/CHbT), respectively. All image processing was performed using MATLAB version 2018b (MathWorks, South Natick, Massachusetts).

2.4.

Statistical Analysis

Only one area was used for each dorsal and head area of each rat for data analysis of hyperspectral images. A region of interest (ROI) of 330×330  pixels was set at the burn wound area in each image, and mean and standard deviation (SD) over the ROI were calculated for analyses of the time courses of CmetHbCHbO, CHbR, CHbT, StO2, and StMet. Data are thus expressed as mean ± SD. To compare differences in each parameter across burn depth conditions, the mean of three rats in each group was also calculated. An unpaired t-test was performed to compare mean values over samples among groups, with values of P<0.05 considered statistically significant. CDA was performed to discriminate 70°C burns, 78°C burns, and 98°C burns from estimated values of CHbT, StO2, and StMet by the proposed method. In this CDA, the time T (s) after burn injury and mean values of CHbT, StO2, and StMet over the ROI and their second-order terms were used as predictor variables, while the categories of burn depth (i.e., 70°C burn, 78°C burn, and 98°C burn) were coded as integers and used as response variables. Wilks’ lambda distribution was used to evaluate the significance of separations. The results of discrimination were evaluated by canonical discriminant plots, and the percentage of correct prediction for each sample was evaluated using leave-one-out cross-validation. Discrimination performance was evaluated using a receiver operating characteristic (ROC) curve. Area under the ROC curve (AUC) was calculated to quantify discrimination. In each group, 7 of the 11 rats were used for the training data set to establish the canonical discriminant equations. The remaining four rats were used to provide test data for burn depth classification images.

2.5.

Visualizing Spatial Distributions of Burn Depths

We proposed a method to visualize the spatial distribution of burn depths based on CDA with images of CHbT, StO2, and StMet. Figure 2 shows the process for constructing a 2D burn depth classification image. First, images of CHbT, StO2, and StMet are estimated from SDRI of the dorsal skin of a rat using the method based on multiple regression analysis supported by the MCS.32 Applying the canonical discriminant equations established by the CDA described in Sec. 2.4 to each pixel of images for CHbT, StO2, and StMet, 2D distributions of canonical scores z1 and z2 are obtained. Pixel-by-pixel calculations of the distance between a coordinate (z1,z2) and the mean value of each burn depth group on the canonical plot finally visualize the spatial map of burn depth.

Fig. 2

Process of constructing a 2D burn depth classification image.

JBO_29_2_026003_f002.png

3.

Results and Discussion

Figure 3 shows typical color photographs obtained from rat dorsal skin before burn, and 5 min, 24 h, 48 h, and 72 h after burn injury for 70°C burn, 78°C burn, and 98°C burn. The skin color before the burn was a pale pink tone. The skin color for the 70°C burn and the 78°C burn retained a pale pink tone at 5 min after burn injury, but the tone decreased in the skin for the 98°C burn. The skin color for the 70°C burn became a light reddish-purple at 24 h after burn, but the pale pink tone recovered at 48 and 72 h after burn. The skin color for the 78°C burn showed a pale yellowish tone at 24 h after burn, and some wrinkles appeared on the surface which is probably due to shrinkage of the injured skin tissue. The skin color for the 98°C burn became a grayish tone at 24 and 48 h after burn and it changed to slightly yellowish at 72 h.

Fig. 3

Typical color photographs obtained from rat dorsal skin before burn, and 5 min, 24 h, 48 h, and 72 h after burn injury for 70°C burn, 78°C burn, and 98°C burn.

JBO_29_2_026003_f003.png

Figure 4 shows typical time course of absorbance spectra obtained from rat dorsal skin before burn, and 5 min, 24 h, 48 h, and 72 h after burn injury for 70°C burn, 78°C burn, and 98°C burn. Each spectrum is the average value over the ROI in the spectral absorbance image and is compared to the absorbance spectrum fitted by the multiple regression analysis with the molar extinction coefficient spectra of oxygenated hemoglobin, deoxygenated hemoglobin, methemoglobin, and melanin. The absorbance values for 78°C burn and 98°C burn in the range from 610 to 650 nm were slightly increased 24 h after burn injury, which implies increases in CmetHb. Each fitted spectrum shows good agreement with the measured spectrum in the 550 to 680 nm wavelength range. The coefficient of determination R2, for each fitted spectrum ranged from 0.92 to 0.97, indicating a high goodness of fit. The absorbance values for 78°C burn and 98°C burn in the range from 420 to 540 nm were elevated 48 and 72 h after burn injury, indicating an increase in bilirubin due to hemoglobin breakdown. In this study, the multiple regression analysis was performed using a spectrum between 550 and 680 nm. Therefore, the presence of bilirubin, which has no absorption in this wavelength range, would not affect the goodness of fit.

Fig. 4

Typical time course of absorbance spectra obtained from rat dorsal skin before burn, and 5 min, 24 h, 48 h, and 72 h after burn injury for (a) 70°C burn, (b) 78°C burn, and (c) 98°C burn.

JBO_29_2_026003_f004.png

Figure 5 shows typical sequential images for CHbT, StO2, and StMet before and after SDB, DDB, and DB in rat dorsal skin. Figure 6 shows the time courses of CHbT, StO2, and StMet before and after 70°C burn, 78°C burn, and 98°C burn in rat dorsal skin averaged over the ROI of each corresponding image obtained from all samples. Plots and error bars show means and SDs for seven rats in each burn injury group (i.e., 70°C burn, 78°C burn, and 98°C burn) in rat dorsal skin. In Figs. 5(a) and 6(a), CHbT in the 70°C burn group showed different time courses from those in the 78°C burn and 98°C burn groups. In the 70°C burn group, CHbT increased significantly from 24 to 72 h after burn injury. Conversely, in the 78°C burn and 98°C burn groups, CHbT remained decreased compared to pre-burn levels from 24 to 72 h after burn injury. CHbT in 70°C burn has been reported to be significantly increased, peaking at 48 h after burn injury and continuing to increase until at least 72 h.6 In contrast, CHbT in 78°C burn continued to decrease over time. Total hemoglobin has been observed to be elevated in 70°C burn, but stable in 78°C burn.38 In thermally injured tissues, microcirculation is progressively disrupted due to tissue destruction, vascular occlusion, microvascular endothelial changes, and thrombus formation. This leads to changes in total hemoglobin concentration in different types of burn injury. One possible explanation for these changes is venous blood pooling due to impaired vascular supply.

Fig. 5

Typical sequential images of (a) CHbT, (b) StO2, and (c) StMet before and after 70°C burn, 78°C burn, and 98°C burn in rat dorsal skin.

JBO_29_2_026003_f005.png

Fig. 6

Time courses of (a) CHbT, (b) StO2, and (c) StMet before and after 70°C burn, 78°C burn, and 98°C burn in rat dorsal skin averaged over the ROI for each corresponding image obtained from all samples. Plots and error bars show means and SDs of seven rats in each burn injury group (i.e., 70°C burn, 78°C burn, and 98°C burn) in rat dorsal skin.

JBO_29_2_026003_f006.png

In Figs. 5(b) and 6(b), StO2 for 70°C burn was increased immediately (i.e., 5 min) after burn injury, then decreased at 24 h, and finally continued to increase at 48 to 72 h to reach its pre-burn level. On the other hand, in the 78°C burn and 98°C burn groups, StO2 remained decreased at 24 h after burn injury, then increased slightly to reach the pre-burn level at 48 to 72 h after burn injury. These results are consistent with findings from other researchers for 70°C burn, but the results for 78°C burn and 98°C burn did not match previous findings at 24 h, and finally at 48 to 72 h after burn injury, all types of burn depth showed oxygen saturation at pre-burn levels.6 Previous researchers have also reported similar findings to our results that tissue oxygen saturation appeared to be significantly increased immediately after burn, but these differences were not evident at 24, 48, and 72 h after burn.38

Figures 5(c) and 6(c) show that StMet for 70°C burn was increased immediately after burn injury and reached the maximum level at 24 h after burn injury, then returned to the pre-burn level by 48 h after burn injury. In contrast, StMet for 78°C burn and 98°C burn started to increase immediately after burn injury and continued to increase at 24, 48, and 72 h after burn injury. The time courses for estimated StMet changed depending on burn depth. The mechanisms underlying increased methemoglobin content in burn wounds have been discussed elsewhere.3941 StMet appears to be one of the most important parameters for burn depth and provides unique ways to assess and characterize different types of burns, and these findings also suggest that quantifying StMet may provide a critical indicator of the extent of damage within the burn wound.31.39,42 Methemoglobin is formed by the oxidation of iron moieties in normal hemoglobin from the ferrous to the ferric state. Levels may thus be increased in injured tissue because of the increased levels of reactive oxygen species (ROS) generated by neutrophils and reactive nitrogen species (RNS), such as nitric oxide.41,4345 Temporal differences in the influx of neutrophils into tissues reportedly exist between SDB and DDs in human patients.30 Oxidation of deoxygenated hemoglobin and oxygenated hemoglobin by RNS also produces methemoglobin.46

Figure 7 shows the time courses of CHbT, StO2, and StMet for 70°C burn, 78°C burn, and 98°C burn for rat head skin (non-burned site). In the non-injured head skin distal to the burn wound, there were no significant changes in StMet from pre-burn levels for all (70°C burn, 78°C burn, 98°C burn) groups. An initial decrease in CHbT was observed in both the 78°C burn and 98°C burn groups, which was followed by gradual recovery for 72 h. On the other hand, CHbT for the 70°C burn group showed a minimum value at 48 h after burn injury. There was no correlation between changes in CHbT, StO2, and StMet observed at non-burn sites and those observed at burn sites. Therefore, the changes in CHbT, StO2, and StMet observed at the burn site are specific only to burn depth.

Fig. 7

Time courses of (a) CHbT, (b) StO2, and (c) StMet for 70°C burn, 78°C burn, and 98°C burn for rat head skin (non-burned site).

JBO_29_2_026003_f007.png

Figure 8 shows the canonical discriminant plots obtained from CDA. The plots showed reasonable separation among 70°C burn, 78°C burn, and 98°C burn over time. In this study, 89.29%, 53.57%, and 92.86% of the original grouped cases for 70°C burn, 78°C burn, and 98°C burn were correctly classified, respectively, compared to 89.29%, 42.86%, and 89.29%, respectively, of cross-validated grouped cases.

Fig. 8

Scatter plots from CDA.

JBO_29_2_026003_f008.png

Figure 9 shows the ROC curves of the 70°C burn, 78°C burn, and 98°C burn groups. AUCs for the 70°C burn, 78°C burn, and 98°C burn groups were 0.92, 0.78, and 0.88, respectively. As expected from the canonical scatterplot results in Fig. 7, ROC curves of the 70°C burn group showed AUCs exceeding 0.9, indicating excellent discrimination accuracy. In the 98°C burn group, the AUC was 0.88, a sign of good discrimination accuracy. On the other hand, AUC for the 78°C burn was <0.8, indicating fair discrimination accuracy. Overall, this discriminatory approach using only hemoglobin derivatives information appears promising for the classification of 70°C burn, 78°C burn, and 98°C burn within 72 h after burn injury.

Fig. 9

ROC curves of 70°C burn, 78°C burn, and 98°C burn groups.

JBO_29_2_026003_f009.png

Figure 10 shows the typical sequential images of burn depth classifications obtained from the groups exposed to 70°C, 78°C, and 98°C water. Figure 11 shows the occupancy rate of pixels classified as 70°C burn, 78°C burn, and 98°C burn in each image averaged over the four samples for each group at 5 min, 24 h, 48 h, and 72 h after burn injury. For the dorsal skin of rats exposed to 70°C water, the resulting burn depth classification images mostly comprised 70°C burn and 78°C burn regions at 5 min immediately after burn injury. Conversely, areas classified as 70°C burn dominated at 24 to 72 h after burn injury. For the dorsal skin of rats exposed to 78°C water, most areas in burn depth images for all four samples were classified as 78°C burn at 5 min after burn injury, whereas images comprised 70°C burn, 78°C burn, and 98°C burn regions at 24 to 72 h after burn injury. For the dorsal skin of rats exposed to 98°C water, burn depth classification images comprised 70°C burn, 78°C burn, and 98°C burn regions at 5 min after burn injury. Areas classified as 98°C burn dominated at 24 to 72 h after burn injury.

Fig. 10

Typical sequential images for burn depth classification obtained from groups of rats with dorsal skin exposed to hot water at (a) 70°C, (b) 78°C, and (c) 98°C.

JBO_29_2_026003_f010.png

Fig. 11

Occupancy rate of pixels classified as 70°C burn, 78°C burn, and 98°C burn in each image averaged over the four samples for each group at (a) 5 min, (b) 24 h, (c) 48 h, and (d) 72 h after burn injury.

JBO_29_2_026003_f011.png

Burn wounds are not usually uniform in depth, and many comprise a mixture of deep and superficial components.47,48 A study using photoacoustic imaging of rat burn wounds induced by the Walker–Mason method showed that the signal representing burn depth was site-dependent, even though uniform heating had been used to create the burn injuries.35 This is consistent with the results from burn depth classification images shown in Figs. 9(b) and 10.

Most areas of images from the group with skin exposed to 70°C or 98°C water were classified as 70°C burn or 98°C burn, respectively. In contrast, no significant differences between areas classified as 78°C burn and 98°C burn at 24 to 72 h were seen in the group with skin exposed to 78°C water. One possible explanation is that burn depth changed from 78°C burn to 98°C burn, since burn wounds are dynamic and can progress as well as convert to deeper wounds.42,49

In this study, 2D images of burn depth were created based on the results of CDA with the parameters of hemoglobin derivatives. Investigation with CDA showed reasonable results for discriminating between 70°C burn, 78°C burn, and 98°C burn at 48 to 72 h after burn injury and for differentiating the 78°C burn group from the 70°C burn and 98°C burn groups immediately after burn injury. Similar findings have been reported by other researchers when assessing burn depth using hyperspectral imaging.49

In our previous work,33 CDA was performed separately at four different time points: 5 min, 24 h, 48 h, and 72 h after injury, and discriminant equations were calculated for each time point. Practically, it would be better to prepare discriminant equations that can be applied to an arbitrary time point. Therefore, in this study, CHbT, StO2, and StMet for all time points were combined into one data set for predictor variables of CDA. In addition, elapsed time after the burn injury T was added as a predictor variable. This allows classification of burn severity at any time up to 72 h after injury. The method relies on a small training and validation dataset in this study. Therefore, we performed leave-on-out cross-validation to evaluate the percentage of correct prediction for each sample in CDA with the small dataset. CHbT, StO2, and StMet from 21 samples (7 rats × 3 burn severities) were used as the training data set in each CDA in our previous work.33 In contrast, this study used CHbT, StO2, StMet, and T from 84 samples (7 rats × 3 burn severities × 4 time points) as training data in single CDA. The number of samples for single CDA in this study is larger than that in our previous work.33 Therefore, the statistical power of CDA in this study is higher than that in the previous study.

The proposed method cannot yet be claimed to accurately classify 70°C burn, 78°C burn, and 98°C burn based only on the results of this study. We also applied a new approach based on CDA for differentiating burn depth. Burn depth images were obtained from the data set of CHbT, StO2, and StMet, allowing 70°C burn and 98°C burn to be easily classified, but showing a mixture of pixels of all burn depths for 78°C burn. We used mean ROI values for CHbT, StO2, and StMet as predictive variables to derive the canonical discriminant equations. However, as shown in Fig. 5, CHbT, StO2, and StMet displayed spatial heterogeneity. In addition, mean ROIs for CHbT, StO2, and StMet could vary between samples. Although the Walker–Mason method is a well-established protocol for inducing burn wounds with relatively high reproducibility, few studies have investigated the spatial uniformity of burn depths induced by this method. We assumed that burn depths in the dorsal skin of rats exposed to 70°C, 78°C, and 98°C water represented SDB, DDB, and DB, respectively, based on the literature.36 However, some discrepancies may have existed between assumed and actual burn depths for each sample. Determination of burn depth from histopathological observations of different regions of the burn site at different time points is needed to assign the category names of SDB, DDB, and DB to the response variable in CDA. This should be investigated in future work.

We measured all hemoglobin parameters at 5 min after burn injury because we were interested in the changes in these parameters and the classification of burn depth under the proposed approach based on CDA immediately after burn injury, although differentiating burn depth at 5 min after burn injury offers no real clinical value. The present method lacks depth resolution, since it relies on integrating all the diffuse reflectance information from 550 to 680 nm along the depth direction, which may represent one factor limiting the accuracy of burn depth classifications. Therefore, it is difficult to determine with this method whether the observed chromophore changes originate from the injured tissue alone or from both the injured and underlying non-injured tissues. We simply selected the central area (330×330  pixels) of the measured image as the ROI. Considering the heterogeneity of the estimated images for CHbT, StO2, and StMet, it is expected that differences in the size and position of the ROI may affect the model predictions.

When the proposed method is applied to humans, a large number of CHbT, StO2, and StMet data for burn sites of different severity should be collected from human patients and used as a training data set for CDA. Because albino rats were used in this study, the amount of melanin was close to 0% at all burn severities. In humans, melanin may be present in superficial burns and SDBs, but in deeper burns, the epidermis may be severely damaged and may slough off. In such cases, there will be no melanin present at the burn wounds.

We also performed spectral imaging of pre-burn dorsal skin and pre- and post-burn head skin, and estimated the values of CHbT, StO2, and StMet. The aim of this study was to classify the severity of burn injuries at the burn wound sites. Therefore, we considered three categories in CDA: 70°C burn, 78°C burn, and 98°C burn, but did not include non-burn areas in the data set. Therefore, the burn severity classification map did not include results for non-burned areas. It will be possible to classify the map into four categories of 70°C burns, 78°C burns, 98°C burns, and non-burns by including data sets of CHbT, StO2, and StMet obtained from non-burn sites in CDA.

Several researchers have reported methods for near infrared diffuse reflectance analysis of burns.30,39,42,50 These methods can detect changes in water content in burn wounds, which would be useful for assessing burn edema. In addition to the absorption properties of burn wounds, scattering properties have also shown utility in the assessment of burn depth.51 In this study, empirical formulas for chromophore concentrations were derived from the MCS with a typical spectrum of light-scattering coefficients. Our current method therefore does not account for variations in the light scattering properties of the skin model. However, this spectrum tends to vary from one part of the body to another and may also vary with the age of the individual. Variability in scattering coefficient spectra may thus affect the accuracy of estimating chromophore concentrations. Although this study focused on changes in hemoglobin derivatives, the accuracy of classifying burn depth may be possible using the light-scattering parameter as one variable in CDA.

Early and accurate assessment of the burn depth is important because the current burn management strategy is early excision and skin grafting of all deep dermal and full-thickness burns.52 The current standard waiting time for a decision to graft or continue wound care is 3 to 7 days post-burn.51 Laser Doppler imaging is the only technique approved by the FDA for burn assessment. It has been shown to reduce surgical workload by eliminating unnecessary surgeries and is used to predict burn healing between 48 h and 5 days post-burn.12 The proposed approach with CDA for CHbT, StO2, and StMet in burn wounds showed reasonable results for discriminating between 70°C burn, 78°C burn, and 98°C burn at 48 to 72 h after burn injury and for discriminating the 78°C burn group from the 70°C burn and 98°C burn groups immediately after burn injury. Therefore, the proposed method can meet the clinical need for diagnosis as soon as possible after injury and for use in decision making for grafting or continuation of burn wound care.

When using this method to evaluate DBs in human skin, which is thicker than rat skin, it is better to analyze the diffuse reflectance spectrum at longer wavelengths, which has a greater optical penetration depth. The light penetration depth in the range of 550 to 680 nm roughly reflects the sampling depth in this study, but it depends on the absorption coefficient (i.e., the amount of each chromophore) and the scattering coefficient of the tissue in this wavelength range. Therefore, it is difficult to determine with this method whether the observed chromophore changes originate from the injured tissue alone or from both the injured and underlying non-injured tissues. Our results showed that the amount of each chromophore varies depending on the severity of the burn injury. This means that the sampling depth changes depending on the severity of the burn. It has been reported that in deep partial thickness and full thickness burns, the reduced scattering coefficients decrease significantly after burn injury.51 The decrease in light scattering will result in an increase in light penetration depth. Several researchers21,39,42 conducted the experimental study with more granularity of depths than the number of classifiers used in this study. Experiments using a rat thermal injury model with finely segmented burn depths should be conducted in future work.

4.

Conclusions

In summary, a new method for classifying and imaging burn depth in rats based on SDRI was demonstrated in this study. The proposed approach with CDA for StO2, StMet, and CHbT in burn wounds showed reasonable results for discriminating between 70°C burn, 78°C burn, and 98°C burn at 48 to 72 h after burn injury and for discriminating the 78°C burn group from the 70°C burn and 98°C burn groups immediately after burn injury. The proposed approach combining SDRI and CDA shows potential for differentiating between degrees of burns in a rat model of scald burn injury.

Disclosures

The authors declare no conflicts of interest.

Code and Data Availability

Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request and through a collaboration agreement.

Acknowledgments

This paper was a revised version of a report previously published in SPIE Conference Proceedings, volume 12327, 123270H (2023).

References

1. 

K. C. Lee, K. Joory and N. S. Moiemen, “History of burns: the past, present and the future,” Burns Trauma, 2 (4), 169 –180 https://doi.org/10.4103/2321-3868.143620 (2014). Google Scholar

2. 

J. T. Whitton and J. D. Everall, “The thickness of the epidermis,” Br. J. Dermatol., 89 (5), 467 –476 https://doi.org/10.1111/j.1365-2133.1973.tb03007.x BJDEAZ 0007-0963 (1973). Google Scholar

3. 

M. G. Jeschke et al., “Burn injury,” Nat. Rev. Dis. Primers, 6 (1), 11 https://doi.org/10.1038/s41572-020-0145-5 (2020). Google Scholar

4. 

D. D. Sampson, T. R. Hilman, “Optical coherence thomography,” Lasers and Current Optical Techniques in Biology, 549 The Royal Society of Chemistry, p.  (2004). Google Scholar

5. 

S. V. Parasca et al., “Hyperspectral index-based metric for burn depth assessment,” Biomed. Opt. Express, 9 (11), 5778 –5791 https://doi.org/10.1364/BOE.9.005778 BOEICL 2156-7085 (2018). Google Scholar

6. 

M. S. Chin et al., “Hyperspectral imaging for burn depth assessment in an animal model,” Plast. Reconstr. Surg. Glob. Open., 3 (12), e591 https://doi.org/10.1097/GOX.0000000000000558 (2016). Google Scholar

7. 

Y. S. Park et al., “The impact of laser Doppler imaging on the early decision-making process for surgical intervention in adults with indeterminate burns,” Burns, 39 (4), 655 –661 https://doi.org/10.1016/j.burns.2012.09.004 BURND8 0305-4179 (2013). Google Scholar

8. 

R. M. Johnson and R. Richard, “Partial-thickness burns: identification and management,” Adv. Skin Wound Care, 16 (4), 178 –187 https://doi.org/10.1097/00129334-200307000-00010 (2013). Google Scholar

9. 

A. D. Jaskille et al., “Critical review of burn depth assessment techniques: part I. Historical review,” J. Burn Care Res., 30 (6), 937 –947 https://doi.org/10.1097/BCR.0b013e3181c07f21 (2009). Google Scholar

10. 

B. Alsbjörn, J. Micheels and B. Sørensen, “Laser Doppler flowmetry measurements of superficial dermal, deep dermal and subdermal burns,” Scand. J. Plast. Reconstr. Surg., 18 (1), 75 –79 https://doi.org/10.3109/02844318409057406 (1984). Google Scholar

11. 

D. Heimbach et al., “Burn depth: a review,” World J. Surg., 16 (1), 10 –15 https://doi.org/10.1007/BF02067108 WJSUDI 0364-2313 (1992). Google Scholar

12. 

S. Monstrey et al., “Assessment of burn depth and burn wound healing potential,” Burns, 34 (6), 761 –769 https://doi.org/10.1016/j.burns.2008.01.009 BURND8 0305-4179 (2008). Google Scholar

13. 

L. M. Bariar et al., “A clinico-pathological study of infections in burn patients and importance of biopsy,” J. Indian Med. Assoc., 95 573 –575 (1997). Google Scholar

14. 

J. M. Still et al., “Diagnosis of burn depth using laser-induced indocyanine green fluorescence: a preliminary clinical trial,” Burns, 27 (4), 364 –371 https://doi.org/10.1016/S0305-4179(00)00140-6 BURND8 0305-4179 (2001). Google Scholar

15. 

A. Renkielska et al., “Active dynamic infrared thermal imaging in burn depth evaluation,” J. Burn Care Res., 35 (5), e294 –e303 https://doi.org/10.1097/BCR.0000000000000059 (2014). Google Scholar

16. 

R. E. Goans, Jr. J. H. Cantrell and F. B. Meyers, “Ultrasonic pulse-echo determination of thermal injury in deep dermal burns,” Med. Phys., 4 (3), 259 –263 https://doi.org/10.1118/1.594376 MPHYA6 0094-2405 (1977). Google Scholar

17. 

T. L. Wachtel et al., “B-mode ultrasonic echo determination of depth of thermal injury,” Burns, 12 (6), 432 –437 https://doi.org/10.1016/0305-4179(86)90040-9 BURND8 0305-4179 (1986). Google Scholar

18. 

J. A. Brink et al., “Quantitative assessment of burn injury in porcine skin with high-frequency ultrasonic imaging,” Invest. Radiol., 21 (8), 645 –651 https://doi.org/10.1097/00004424-198608000-00008 INVRAV 0020-9996 (1986). Google Scholar

19. 

S. E. Elamin, J. K. Dickson and I. P. Mackie, “Is laser Doppler imaging (LDI) a measure of burn depth?,” Burns, 41 (2), 413 https://doi.org/10.1016/j.burns.2014.08.027 BURND8 0305-4179 (2015). Google Scholar

20. 

M. A. Altintas et al., “Differentiation of superficial-partial vs. deep-partial thickness burn injuries in vivo by confocal-laser-scanning microscopy,” Burns, 35 (1), 80 –86 https://doi.org/10.1016/j.burns.2008.05.003 BURND8 0305-4179 (2009). Google Scholar

21. 

T. Ida et al., “Real-time photoacoustic imaging system for burn diagnosis,” J. Biomed. Opt., 19 (8), 086013 https://doi.org/10.1117/1.JBO.19.8.086013 JBOPFO 1083-3668 (2014). Google Scholar

22. 

M. Kaiser et al., “Noninvasive assessment of burn wound severity using optical technology: a review of current and future modalities,” Burns, 37 (3), 377 –386 https://doi.org/10.1016/j.burns.2010.11.012 BURND8 0305-4179 (2011). Google Scholar

23. 

M. J. Koruda et al., “Assessing burn wound depth using in vitro nuclear magnetic resonance (NMR),” J. Surg. Res., 40 (5), 475 –481 https://doi.org/10.1016/0022-4804(86)90218-0 JSGRA2 0022-4804 (1986). Google Scholar

24. 

B. S. Sorg et al., “Hyperspectral imaging of hemoglobin saturation in tumor microvasculature and tumor hypoxia development,” J. Biomed. Opt., 10 (4), 044004 https://doi.org/10.1117/1.2003369 JBOPFO 1083-3668 (2005). Google Scholar

25. 

S. F. Bish et al., “Handheld diffuse reflectance spectral imaging (DRSi) for in-vivo characterization of skin,” Biomed. Opt. Express, 5 (2), 573 –586 https://doi.org/10.1364/BOE.5.000573 BOEICL 2156-7085 (2014). Google Scholar

26. 

A. Nkengne et al., “SpectraCam® : a new polarized hyperspectral imaging system for repeatable and reproducible in vivo skin quantification of melanin, total hemoglobin, and oxygen saturation,” Skin Res. Technol., 24 (1), 99 –107 https://doi.org/10.1111/srt.12396 (2018). Google Scholar

27. 

D. Yudovsky, A. Nouvong and L. Pilon, “Hyperspectral imaging in diabetic foot wound care,” J. Diabetes Sci. Technol., 4 (5), 1099 –1113 https://doi.org/10.1177/193229681000400508 (2010). Google Scholar

28. 

I. Nishidate et al., “Noninvasive spectral imaging of skin chromophores based on multiple regression analysis aided by Monte Carlo simulation,” Opt. Lett., 36 (16), 3239 –3241 https://doi.org/10.1364/OL.36.003239 OPLEDP 0146-9592 (2011). Google Scholar

29. 

M. A. Calin et al., “Characterization of burns using hyperspectral imaging technique: a preliminary study,” Burns, 41 (1), 118 –124 https://doi.org/10.1016/j.burns.2014.05.002 BURND8 0305-4179 (2015). Google Scholar

30. 

G. Leung et al., “Rapid tissue viability evaluation using methemoglobin as a biomarker in burns,” Int. J. Burns Trauma, 8 (5), 126 –134 (2018). Google Scholar

31. 

G. Saiko, “Methemoglobin: a new way to distinguish burn depth,” Adv. Exp. Med. Biol., 977 359 –365 https://doi.org/10.1007/978-3-319-55231-6_47 AEMBAP 0065-2598 (2017). Google Scholar

32. 

F. Khatun, Y. Aizu and I. Nishidate, “Transcutaneous monitoring of hemoglobin derivatives during methemoglobinemia rats using spectral diffuse reflectance,” J. Biomed. Opt., 26 (3), 033708 https://doi.org/10.1117/1.JBO.26.3.033708 JBOPFO 1083-3668 (2021). Google Scholar

33. 

A. Parvez et al., “In vivo monitoring of hemoglobin derivatives in a rat thermal injury model using spectral diffuse reflectance imaging,” Burns, 50 (1), 167 –177 https://doi.org/10.1016/j.burns.2023.07.006 BURND8 0305-4179 (2024). Google Scholar

34. 

H. L. Walker and Jr. A. D. Mason, “A standard animal burn,” J. Trauma, 8 (6), 1049 –1051 https://doi.org/10.1097/00005373-196811000-00006 (1968). Google Scholar

35. 

K. Aizawa et al., “Photoacoustic monitoring of burn healing process in rats,” J. Biomed. Opt., 13 (6), 064020 https://doi.org/10.1117/1.3028005 JBOPFO 1083-3668 (2008). Google Scholar

36. 

S. Sato et al., “Photoacoustic diagnosis of burns in rats,” J. Trauma, 59 (6), 1450 –1455 https://doi.org/10.1097/01.ta.0000197389.94466.04 (2005). Google Scholar

37. 

L. Wang, S. L. Jacques and L. Zheng, “MCML: Monte Carlo modeling of light transport in multi-layered tissues,” Comput. Methods Prog. Biomed., 47 (2), 131 –146 https://doi.org/10.1016/0169-2607(95)01640-F CMPBEK 0169-2607 (1995). Google Scholar

38. 

H. Ding and R. C. Chang, “Hyperspectral imaging with burn contour extraction for burn wound depth assessment,” ASME J. Med. Diagn., 1 (4), 041002 https://doi.org/10.1115/1.4040470 (2018). Google Scholar

39. 

K. M. Cross, “Assessment of tissue viability in acute thermal injuries using near infrared point spectroscopy,” University of Toronto, (2010). Google Scholar

40. 

J. W. Horton, “Free radicals and lipid peroxidation mediated injury in burn trauma: the role of antioxidant therapy,” Toxicology, 189 (1–2), 75 –88 https://doi.org/10.1016/S0300-483X(03)00154-9 TXCYAC 0300-483X (2003). Google Scholar

41. 

M. Valko et al., “Free radicals and antioxidants in normal physiological functions and human disease,” Int. J. Biochem. Cell Biol., 39 (1), 44 –84 https://doi.org/10.1016/j.biocel.2006.07.001 IJBBFU 1357-2725 (2007). Google Scholar

42. 

R. B. Saager et al., “Impact of hemoglobin breakdown products in the spectral analysis of burn wounds using spatial frequency domain spectroscopy,” J. Biomed. Opt., 24 (2), 020501 https://doi.org/10.1117/1.JBO.24.2.020501 JBOPFO 1083-3668 (2009). Google Scholar

43. 

M. S. Mulligan et al., “Role of leukocyte adhesion molecules in lung and dermal vascular injury after thermal trauma of skin,” Am. J. Pathol., 144 (5), 1008 –1015 AJPAA4 0002-9440 (1994). Google Scholar

44. 

G. O. Till et al., “Role of xanthine oxidase in thermal injury of skin,” Am. J. Pathol., 135 (1), 195 –202 AJPAA4 0002-9440 (1989). Google Scholar

45. 

A. Parihar et al., “Oxidative stress and anti-oxidative mobilization in burn injury,” Burns, 34 (1), 6 –17 https://doi.org/10.1016/j.burns.2007.04.009 BURND8 0305-4179 (2008). Google Scholar

46. 

J. Umbreit, “Methemoglobin: it’s not just blue: a concise review,” Am. J. Hematol., 82 (2), 134 –144 https://doi.org/10.1002/ajh.20738 AJHEDD 1096-8652 (2007). Google Scholar

47. 

D. M. Mertens, M. E. Jenkins and G. D. Warden, “Outpatient burn management,” Nurs. Clin. North Am., 32 (2), 343 –364 https://doi.org/10.1016/S0029-6465(22)02191-0 (1997). Google Scholar

48. 

C. R. Baxter, “Management of burn wounds,” Dermatol. Clin., 11 (4), 709 –714 https://doi.org/10.1016/S0733-8635(18)30223-7 DERAEG 1018-8665 (1993). Google Scholar

49. 

W. Eisenbeiss, J. Marotz and J. P. Schrade, “Reflection-optical multispectral imaging method for objective determination of burn depth,” Burns, 25 (8), 697 –704 https://doi.org/10.1016/S0305-4179(99)00078-9 BURND8 0305-4179 (1999). Google Scholar

50. 

J. Lee et al., “Noninvasive in vivo monitoring of methemoglobin formation and reduction with broadband diffuse optical spectroscopy,” J. Appl. Physiol. (1985), 100 (2), 615 –622 https://doi.org/10.1152/japplphysiol.00424.2004 (2006). Google Scholar

51. 

A. Mazhar et al., “Noncontact imaging of burn depth and extent in a porcine model using spatial frequency domain imaging,” J. Biomed. Opt., 19 (8), 086019 https://doi.org/10.1117/1.JBO.19.8.086019 JBOPFO 1083-3668 (2014). Google Scholar

52. 

H. Hoeksema et al., “Accuracy of early burn depth assessment by laser Doppler imaging on different days post burn,” Burns, 35 (1), 36 –45 https://doi.org/10.1016/j.burns.2008.08.011 BURND8 0305-4179 (2009). Google Scholar

Biographies of the authors are not available.

CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Md. Anowar Parvez, Kazuhiro Yashiro, Yuki Nagahama, Yasuyuki Tsunoi, Daizoh Saitoh, Shunichi Sato, and Izumi Nishidate "In vivo visualization of burn depth in skin tissue of rats using hemoglobin parameters estimated by diffuse reflectance spectral imaging," Journal of Biomedical Optics 29(2), 026003 (15 February 2024). https://doi.org/10.1117/1.JBO.29.2.026003
Received: 1 November 2023; Accepted: 24 January 2024; Published: 15 February 2024
Advertisement
Advertisement
KEYWORDS
Skin

Injuries

Tissues

Image classification

Visualization

Absorbance

Diffuse reflectance spectroscopy