Purpose: Chest x-rays are complex to report accurately. Viral pneumonia is often subtle in its radiological appearance. In the context of the COVID-19 pandemic, rapid triage of cases and exclusion of other pathologies with artificial intelligence (AI) can assist over-stretched radiology departments. We aim to validate three open-source AI models on an external test set.
Approach: We tested three open-source deep learning models, COVID-Net, COVIDNet-S-GEO, and CheXNet for their ability to detect COVID-19 pneumonia and to determine its severity using 129 chest x-rays from two different vendors Phillips and Agfa.
Results: All three models detected COVID-19 pneumonia (AUCs from 0.666 to 0.778). Only the COVID Net-S-GEO and CheXNet models performed well on severity scoring (Pearson’s r 0.927 and 0.833, respectively); COVID-Net only performed well at either task on images taken with a Philips machine (AUC 0.735) and not an Agfa machine (AUC 0.598).
Conclusions: Chest x-ray triage using existing machine learning models for COVID-19 pneumonia can be successfully implemented using open-source AI models. Evaluation of the model using local x-ray machines and protocols is highly recommended before implementation to avoid vendor or protocol dependent bias.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.